A 61-year-old previously healthy woman developed progressive hearing and visual loss over a period of 2–3 months prior to admission. Her medical/surgical history was remarkable for a left hip arthroplasty 11 years ago requiring revision approximately 6 months prior to admission. After dislocating the revised hip, she re-presented to her surgeon and underwent a closed reduction. Several weeks following the reduction, the patient began having polyuria and symptoms of hearing and vision loss along with numbness in her extremities and abdominal region.
This report displays a rare presentation of lactic acidosis in the setting of status epilepticus (SE). The differential diagnosis of lactic acidosis is broad and typically originates from states of shock; however, this report highlights an alternative and rare etiology, SE, due to chronic skull base erosion from temporomandibular joint (TMJ) disease. Lactic acidosis is defined by a pH below 7.35 in the setting of lactate values greater than 5 mmol/L. Two broad classifications of lactic acidosis exist: a type A lactic acidosis which stems from global or localized tissue hypoxia or a type B lactic acidosis which occurs once mitochondrial oxidative capacity is unable to match glucose metabolism. SE is an example of a type A lactic acidosis in which oxygen delivery is unable to meet increased cellular energy requirements. This report is consistent with a prior case series that consists of five patients experiencing generalized tonic-clonic (GTC) seizures and lactic acidosis. These patients presented with a pH range of 6.8-7.41 and lactate range of 3.8-22.4 mmol/L. Although severe lactic acidosis following GTC has been described, this is the first report in the literature of chronic skull base erosion from TMJ disease causing SE.
We found a 14-fold increase in the volume (ie, dose) delivered per spray when a nasal squeeze bottle was used with a mannequin in the supine position compared with the upright position. Given the reported toxicity from the use of intranasal medication and the inadvertent overdosing that occurs when squeeze bottle atomizers are used in clinical practice, our data suggest that all intranasal drugs should be administered with a precise, metered-dose device. If a metered-dose device is unavailable, the medication should be delivered at an angle of ≥45°; however, we recommend administering the drug with the patient in the sitting position and the bottle at 90° because only a small change in angle below 45° will result in a substantial increase in medication delivered.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.