BackgroundMeasurement of vital signs in hospitalized patients is necessary to assess the clinical situation of the patient. Early warning scores (EWS), such as the modified early warning score (MEWS), are generally calculated 3 times a day, but these may not capture early deterioration. A delay in diagnosing deterioration is associated with increased mortality. Continuous monitoring with wearable devices might detect clinical deterioration at an earlier stage, which allows clinicians to take corrective actions.ObjectiveIn this pilot study, the feasibility of continuous monitoring using the ViSi Mobile (VM; Sotera Wireless) and HealthPatch (HP; Vital Connect) was tested, and the experiences of patients and nurses were collected.MethodsIn this feasibility study, 20 patients at the internal medicine and surgical ward were monitored with VM and HP simultaneously for 2 to 3 days. Technical problems were analyzed. Vital sign measurements by nurses were taken as reference and compared with vital signs measured by both devices. Patient and nurse experiences were obtained by semistructured interviews.ResultsIn total, 86 out of 120 MEWS measurements were used for the analysis. Vital sign measurements by VM and HP were generally consistent with nurse measurements. In 15% (N=13) and 27% (N=23) of the VM and HP cases respectively, clinically relevant differences in MEWS were found based on inconsistent respiratory rate registrations. Connection failure was recognized as a predominant VM artifact (70%). Over 50% of all HP artifacts had an unknown cause, were self-limiting, and never took longer than 1 hour. The majority of patients, relatives, and nurses were positive about VM and HP.ConclusionsBoth VM and HP are promising for continuously monitoring vital signs in hospitalized patients, if the frequency and duration of artifacts are reduced. The devices were well received and comfortable for most patients.
Background Wearable devices can be used for continuous patient monitoring in the general ward, increasing patient safety. Little is known about the experiences and expectations of patients and health care professionals regarding continuous monitoring with these devices. Objective This study aimed to identify positive and negative effects as well as barriers and facilitators for the use of two wearable devices: ViSi Mobile (VM) and HealthPatch (HP). Methods In this randomized controlled trial, 90 patients admitted to the internal medicine and surgical wards of a university hospital in the Netherlands were randomly assigned to continuous vital sign monitoring using VM or HP and a control group. Users’ experiences and expectations were addressed using semistructured interviews. Nurses, physician assistants, and medical doctors were also interviewed. Interviews were analyzed using thematic content analysis. Psychological distress was assessed using the State Trait Anxiety Inventory and the Pain Catastrophizing Scale. The System Usability Scale was used to assess the usability of both devices. Results A total of 60 patients, 20 nurses, 3 physician assistants, and 6 medical doctors were interviewed. We identified 47 positive and 30 negative effects and 19 facilitators and 36 barriers for the use of VM and HP. Frequently mentioned topics included earlier identification of clinical deterioration, increased feelings of safety, and VM lines and electrodes. No differences related to psychological distress and usability were found between randomization groups or devices. Conclusions Both devices were well received by most patients and health care professionals, and the majority of them encouraged the idea of monitoring vital signs continuously in the general ward. This comprehensive overview of barriers and facilitators of using wireless devices may serve as a guide for future researchers, developers, and health care institutions that consider implementing continuous monitoring in the ward. Trial Registration Clinicaltrials.gov NCT02933307; http://clinicaltrials.gov/ct2/show/NCT02933307.
We found a lot of diversity in the organization of MTMs. The variation in compliance with the quality criteria may decrease with better knowledge about the quality criteria around MTMs and by overcoming practical barriers for the effective organization of MTMs.
BackgroundCuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP self-measurement.ObjectiveThe objective of our study was to evaluate the performance of the first release of the Checkme Health Monitor (Viatom Technology), a cuffless BP monitor, in a real-life setting. Furthermore, we wanted to investigate whether the posture of the volunteer and the position of the device relative to the heart level would influence its outcomes.MethodsStudy volunteers fell into 3 BP ranges: high (>160 mmHg), normal (130–160 mmHg), and low (<130 mmHg). All requirements for test environment, observer qualification, volunteer recruitment, and BP measurements were met according to the European Society of Hypertension International Protocol (ESH-IP) for the validation of BP measurement devices. After calibrating the Checkme device, we measured systolic BP with Checkme and a validated, oscillometric reference BP monitor (RM). Measurements were performed in randomized order both in supine and in sitting position, and with Checkme at and above heart level.ResultsWe recruited 52 volunteers, of whom we excluded 15 (12 due to calibration failure with Checkme, 3 due to a variety of reasons). The remaining 37 volunteers were divided into low (n=14), medium (n=13), and high (n=10) BP ranges. There were 18 men and 19 women, with a mean age of 54.1 (SD 14.5) years, and mean recruitment systolic BP of 141.7 (SD 24.7) mmHg. BP results obtained by RM and Checkme correlated well. In the supine position, the difference between the RM and Checkme was >5 mmHg in 17 of 37 volunteers (46%), of whom 9 of 37 (24%) had a difference >10 mmHg and 5 of 37 (14%) had a difference >15 mmHg.ConclusionsBP obtained with Checkme correlated well with RM BP, particularly in the position (supine) in which the device was calibrated. These preliminary results are promising for conducting further research on cuffless BP measurement in the clinical and outpatient settings.
BackgroundVital sign measurements in hospitalized patients by nurses are time consuming and prone to operational errors. The Checkme, a smart all-in-one device capable of measuring vital signs, could improve daily patient monitoring by reducing measurement time, inter-observer variability, and incorrect inputs in the Electronic Health Record (EHR). We evaluated the accuracy of self measurements by patient using the Checkme in comparison with gold standard and nurse measurements.Methods and findingsThis prospective comparative study was conducted at the Internal Medicine ward of an academic hospital in the Netherlands. Fifty non-critically ill patients were enrolled in the study. Time-related measurement sessions were conducted on consecutive patients in a randomized order: vital sign measurement in duplicate by a well-trained investigator (gold standard), a Checkme measurement by the patient, and a routine vital sign measurement by a nurse. In 41 patients (82%), initial calibration of the Checkme was successful and results were eligible for analysis. In total, 69 sessions were conducted for these 41 patients. The temperature results recorded by the patient with the Checkme differed significantly from the gold standard core temperature measurements (mean difference 0.1 ± 0.3). Obtained differences in vital signs and calculated Modified Early Warning Score (MEWS) were small and were in range with predefined accepted discrepancies.ConclusionsPatient-calculated MEWS using the Checkme, nurse measurements, and gold standard measurements all correlated well, and the small differences observed between modalities would not have affected clinical decision making. Using the Checkme, patients in a general medical ward setting are able to measure their own vital signs easily and accurately by themselves. This could be time saving for nurses and prevent errors due to manually entering data in the EHR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.