Use of electronic cigarettes has grown exponentially over the past few years, raising concerns about harmful emissions. This study quantified potentially toxic compounds in the vapor and identified key parameters affecting emissions. Six principal constituents in three different refill "e-liquids" were propylene glycol (PG), glycerin, nicotine, ethanol, acetol, and propylene oxide. The latter, with mass concentrations of 0.4-0.6%, is a possible carcinogen and respiratory irritant. Aerosols generated with vaporizers contained up to 31 compounds, including nicotine, nicotyrine, formaldehyde, acetaldehyde, glycidol, acrolein, acetol, and diacetyl. Glycidol is a probable carcinogen not previously identified in the vapor, and acrolein is a powerful irritant. Emission rates ranged from tens to thousands of nanograms of toxicants per milligram of e-liquid vaporized, and they were significantly higher for a single-coil vs a double-coil vaporizer (by up to an order of magnitude for aldehydes). By increasing the voltage applied to a single-coil device from 3.3 to 4.8 V, the mass of e-liquid consumed doubled from 3.7 to 7.5 mg puff(-1) and the total aldehyde emission rates tripled from 53 to 165 μg puff(-1), with acrolein rates growing by a factor of 10. Aldehyde emissions increased by more than 60% after the device was reused several times, likely due to the buildup of polymerization byproducts that degraded upon heating. These findings suggest that thermal degradation byproducts are formed during vapor generation. Glycidol and acrolein were primarily produced by glycerin degradation. Acetol and 2-propen-1-ol were produced mostly from PG, while other compounds (e.g., formaldehyde) originated from both. Because emissions originate from reaction of the most common e-liquid constituents (solvents), harmful emissions are expected to be ubiquitous when e-cigarette vapor is present.
A Hot Start Polymerase Chain Reaction (PCR) entails the withholding of at least one reagent from the reaction mixture until the reaction tube temperature has reached 60-80 degrees C. Hot Start amplification with an AmpliWax vapor barrier uses a layer of solid wax to separate the retained reagent(s) and the test sample from the bulk of the reagents until the first heating step of automated thermal cycling melts the wax and convectively mixes the two aqueous layers. Wax-mediated Hot Start PCR greatly increases the specificity, yield, and precision of amplifying low copy numbers of three HIV targets. In the presence of 1 microgram of human placental DNA (1.6 x 10(5) diploid genomes) the specificity improvement entails considerable to complete reduction in the amplification of mis-primed sequences and putative primer oligomers. When mis-priming is negligible, the procedural improvement still suppresses putative primer oligomerization. Hot Start PCR with an AmpliWax vapor barrier permits routine amplification of a single target molecule with detection by ethidium stained gel electrophoresis; nonisotopically visualized probing suffices for confirmation. The improved amplification performance is evident for target copy numbers below approximately 10(3).
The study results indicate the importance of avoiding low VRs per person and low VRs per floor area to minimize decrements in cognitive performance.
E-cigarettes likely represent a lower risk to health than traditional combustion cigarettes, but they are not innocuous. Recently reported emission rates of potentially harmful compounds were used to assess intake and predict health impacts for vapers and bystanders exposed passively. Vapers' toxicant intake was calculated for scenarios in which different e-liquids were used with various vaporizers, battery power settings and vaping regimes. For a high rate of 250 puff day using a typical vaping regime and popular tank devices with battery voltages from 3.8 to 4.8 V, users were predicted to inhale formaldehyde (up to 49 mg day), acrolein (up to 10 mg day) and diacetyl (up to 0.5 mg day), at levels that exceeded U.S. occupational limits. Formaldehyde intake from 100 daily puffs was higher than the amount inhaled by a smoker consuming 10 conventional cigarettes per day. Secondhand exposures were predicted for two typical indoor scenarios: a home and a bar. Contributions from vaping to air pollutant concentrations in the home did not exceed the California OEHHA 8-h reference exposure levels (RELs), except when a high emitting device was used at 4.8 V. In that extreme scenario, the contributions from vaping amounted to as much as 12 μg m formaldehyde and 2.6 μg m acrolein. Pollutant concentrations in bars were modeled using indoor volumes, air exchange rates and the number of hourly users reported in the literature for U.S. bars in which smoking was allowed. Predicted contributions to indoor air levels were higher than those in the residential scenario. Formaldehyde (on average 135 μg m) and acrolein (28 μg m) exceeded the acute 1-h exposure REL for the highest emitting vaporizer/voltage combination. Predictions for these compounds also exceeded the 8-h REL in several bars when less intense vaping conditions were considered. Benzene concentrations in a few bars approached the 8-h REL, and diacetyl levels were close to the lower limit for occupational exposures. The integrated health damage from passive vaping was derived by computing disability-adjusted life years (DALYs) lost due to exposure to secondhand vapor. Acrolein was the dominant contributor to the aggregate harm. DALYs for the various device/voltage combinations were lower than-or comparable to-those estimated for exposures to secondhand and thirdhand tobacco smoke.
Sixteen apartments serving low-income populations in three buildings were retrofit with the goal of simultaneously reducing energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among apartments and included, among others, envelope sealing, installation of continuous mechanical ventilation systems, upgrading bathroom fans and range hoods, attic insulation, replacement of heating and cooling systems, and adding wall-mounted particle air cleaners. IEQ parameters were measured, generally for two one-week periods before and after the retrofits. The measurements indicate an overall improvement in IEQ conditions after the retrofits. Comfort conditions, bathroom humidity, and concentrations of carbon dioxide, acetaldehyde, volatile organic compounds, and particles generally improved. Formaldehyde and nitrogen dioxide levels decreased in the building with the highest concentrations, were unchanged in a second building, and increased in a third building. IEQ parameters other than particles improved more in apartments with continuous mechanical ventilation systems installed. In general, but not consistently, larger percent increases in air exchange rates were associated with larger percent decreases in indoor levels of the pollutants that primarily come from indoor sources.
A study of the relationship between outside air ventilation rate and concentrations of volatile organic compounds (VOCs) generated indoors was conducted in a call center office building.The building, with two floors and a floor area of 4,600 m 2 , was located in the San Francisco Bay Area, CA. Ventilation rates were manipulated with the building's four air handling units (AHUs). VOC concentrations in the AHU returns were measured on seven days during a 13-week period. VOC emission factors were determined for individual zones on days when they were operating at near steady-state conditions. The emission factor data were subjected to
This study was conducted to assess the current impact of natural gas appliances on air quality in California homes. Data were collected via telephone interviews and measurements inside and outside of 352 homes. Passive samplers measured time‐resolved CO and time‐integrated NOX, NO2, formaldehyde, and acetaldehyde over ~6‐day periods in November 2011 – April 2012 and October 2012 – March 2013. The fraction of indoor NOX and NO2 attributable to indoor sources was estimated. NOX, NO2, and highest 1‐h CO were higher in homes that cooked with gas and increased with amount of gas cooking. NOX and NO2 were higher in homes with cooktop pilot burners, relative to gas cooking without pilots. Homes with a pilot burner on a floor or wall furnace had higher kitchen and bedroom NOX and NO2 compared to homes without a furnace pilot. When scaled to account for varying home size and mixing volume, indoor‐attributed bedroom and kitchen NOX and kitchen NO2 were not higher in homes with wall or floor furnace pilot burners, although bedroom NO2 was higher. In homes that cooked 4 h or more with gas, self‐reported use of kitchen exhaust was associated with lower NOX, NO2, and highest 1‐h CO. Gas appliances were not associated with higher concentrations of formaldehyde or acetaldehyde.
Indoor concentrations of 33 volatile organic chemicals were measured in four unoccupied temporary housing units (THUs) belonging to the U.S. Federal Emergency Management Administration (FEMA). The highest level contaminants in the THUs include formaldehyde, acetic acid, and 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB) with median concentrations of 440, 425, and 36 ppb, respectively. A number of volatile organic compounds (VOCs) were higher than published concentrations in other dwellings, but whole THU emission factors for most chemicals were either lower than or similar to values reported for newly constructed homes. However, several chemicals exceeded previously measured new building emission rates by over a factor of 5. Materials were collected from the THUs, and emission factors were determined using small chambers to identify the potential source of indoor contaminants. The individual materials were grouped by material type, and emissions were used to derive exposure concentrations for comparison to reference values. Using material loading factors and ventilation rates that are relevant to the trailers, all of the material types we tested had at least two chemicals (formaldehyde and nonanal) with derived concentrations in excess of chronic reference exposure levels or odor thresholds. The extensive use of composite wood products, sealants, and vinyl coverings, combined with the low air exchange rates relative to material surface areas, may explain the high concentrations of some VOCs and formaldehyde.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.