BackgroundThe ‘chain of survival’—including early call for help, early cardiopulmonary resuscitation (CPR) and early defibrillation—represents the most beneficial approach for favourable patient outcome after out-of-hospital cardiac arrest (OHCA). Despite increasing numbers of publicly accessible automated external defibrillators (AED) and interventions to increase public awareness for basic life support (BLS), the number of their use in real-life emergency situations remains low.MethodsIn this prospective population-based cross-sectional study, a total of 501 registered inhabitants of Vienna (Austria) were randomly approached via telephone calls between 08/2014 and 09/2014 and invited to answer a standardized questionnaire in order to identify public knowledge and awareness of BLS and AED-use.ResultsWe found that more than 52 percent of participants would presume OHCA correctly and would properly initiate BLS attempts. Of alarming importance, only 33 percent reported that they would be willing to perform CPR and 50 percent would use an AED device. There was a significantly lower willingness to initiate BLS attempts (male: 40% vs. female: 25%; OR: 2.03 [95%CI: 1.39–2.98]; p<0.001) and to use an AED device (male: 58% vs. female: 44%; OR: 1.76 [95%CI: 1.26–2.53]; p = 0.002) in questioned female individuals compared to their male counterparts. Interestingly, we observed a strongly decreasing level of knowledge and willingness for BLS attempts (-14%; OR: 0.72 [95%CI: 0.57–0.92]; p = 0.027) and AED-use (-19%; OR: 0.68 [95%CI: 0.54–0.85]; p = 0.001) with increasing age.ConclusionWe found an overall poor knowledge and awareness concerning BLS and the use of AEDs among the Viennese population. Both female and elderly participants reported the lowest willingness to perform BLS and use an AED in case of OHCA. Specially tailored programs to increase awareness and willingness among both the female and elderly community need to be considered for future educational interventions.
Aim: Prior studies suggest that the use of personal protective equipment might impair the quality of critical care. We investigated the influence of personal protective equipment on out-of-hospital cardiopulmonary resuscitation. Methods: Randomised controlled non-inferiority triple-crossover study. Forty-eight emergency medical service providers, randomized into teams of two, performed 12 min of basic life support (BLS) on a manikin after climbing 3 flights of stairs. Three scenarios were completed in a randomised order: Without personal protective equipment, with personal protective equipment including a filtering face piece (FFP) 2 mask with valve, and with personal protective equipment including an FFP2 mask without valve. The primary outcome was mean depth of chest compressions with a pre-defined non-inferiority margin of 3.5 mm. Secondary outcomes included other measurements of CPR quality, providers' subjective exhaustion levels, and providers' vital signs, including end-tidal CO 2. Results: Differences regarding the primary outcome were well below the pre-defined non-inferiority margins for both control vs. personal protective equipment without valve (absolute difference 1 mm, 95% CI [À1, 2]) and control vs. personal protective equipment with valve (absolute difference 1 mm, [À0.2, 2]). This was also true for secondary outcomes regarding quality of chest compressions and providers' vital signs including etCO 2. Subjective physical strain after BLS was higher in the personal protective equipment groups (Borg 4 (SD 3) without valve, 4 (SD 2) with valve) than in the control group (Borg 3 (SD 2)). Conclusion: PPE including masks with and without expiration valve is safe for use without concerns regarding the impairment of CPR quality.
BackgroundLaypersons' efforts to initiate basic life support (BLS) in witnessed Out-of-Hospital Cardiac Arrest (OHCA) remain comparably low within western society. Therefore, in order to shorten no-flow times in cardiac arrest, several police-based first responder systems equipped with automated external defibrillators (Pol-AED) were established in urban areas, which subsequently allow early BLS and AED administration by police officers. However, data on the quality of BLS and AED use in such a system and its impact on patient outcome remain scarce and inconclusive. MethodsA total of 85 Pol-AED cases were randomly assigned to a gender, age and first rhythm matched non-Pol-AED control group (n = 170) in a 1:2 ratio. Data on quality of BLS were extracted via trans-thoracic impedance tracings of used AED devices. ResultsComparing Pol-AED cases and the control group, we observed a similar compression rate per minute (p = 0.677) and compression ratio (p = 0.651), mirroring an overall high quality of BLS administered by police officers. Time to the first shock was significantly shorter in Pol-AED cases (6 minutes [IQR: 2-10] vs. 12 minutes [IQR: 8-17]; p<0.001). While Pol-AED was not associated with increased sustained return of spontaneous circulation (p = 0.564), a strong and independent impact on survival until hospital discharge (adj. OR: 1.85 [95%CI: 1.06-3.23; p = 0.030]) and a borderline significance for the association with favorable neurological outcome (adj. OR: 1.58 [95%CI: 0.96-2.89; p = 0.052) were observed.
Background Over the past decade Smartphone-based activation (SBA) of Community First Responders (CFR) to out-of-hospital cardiac arrests (OHCA) has gained much attention and popularity throughout Europe. Various programmes have been established, and interestingly there are considerable differences in technology, responder spectrum and the degree of integration into the prehospital emergency services. It is unclear whether these dissimilarities affect outcome. This paper reviews the current state in five European countries, reveals similarities and controversies, and presents consensus statements generated in an international conference with the intention to support public decision making on future strategies for SBA of CFR. Methods In a consensus conference a three-step approach was used: (i) presentation of current research from five European countries; (ii) workshops discussing evidence amongst the audience to generate consensus statements; (iii) anonymous real-time voting applying the modified RAND-UCLA Appropriateness method to adopt or reject the statements. The consensus panel aimed to represent all stakeholders involved in this topic. Results While 21 of 25 generated statements gained approval, consensus was only found for 5 of them. One statement was rejected but without consensus. Members of the consensus conference confirmed that CFR save lives. They further acknowledged the crucial role of emergency medical control centres and called for nationwide strategies. Conclusions Members of the consensus conference acknowledged that smartphone-based activation of CFR to OHCA saves lives. The statements generated by the consensus conference may assist the public, healthcare services and governments to utilise these systems to their full potential, and direct the research community towards fields that still need to be addressed.
Background The COVID-19 pandemic led to widespread use of personal protection equipment (PPE), including filtering face piece (FFP) masks, throughout the world. PPE. Previous studies indicate that PPE impairs neurocognitive performance in healthcare workers. Concerns for personnel safety have led to special recommendations regarding basic life support (BLS) in patients with a potential SARS-CoV-2 infection, including the use of PPE. Established instruments are available to assess attention and dexterity in BLS settings, respectively. We aimed to evaluate the influence of PPE with different types of FFP masks on these two neuropsychological components of EMS personnel during BLS. Methods This was a randomized controlled non-inferiority triple-crossover study. Teams of paramedics completed three 12-min long BLS scenarios on a manikin after having climbed three flights of stairs with equipment, each in three experimental conditions: (a) without pandemic PPE, (b) with PPE including a FFP2 mask with an expiration valve and (c) with PPE including an FFP2 mask without an expiration valve. The teams and intervention sequences were randomized. We measured the shift in concentration performance using the d2 test and dexterity using the nine-hole peg test (NHPT). We compared results between the three conditions. For the primary outcome, the non-inferiority margin was set at 20 points. Results Forty-eight paramedics participated. Concentration performance was significantly better after each scenario, with no differences noted between groups: d2 shift control versus with valve − 8.3 (95% CI − 19.4 to 2.7) points; control versus without valve − 8.5 (− 19.7 to 2.7) points; with valve versus without valve 0.1 (− 11.1 to 11.3) points. Similar results were found for the NHPT: + 0.3 (− 0.7 to 1.4), − 0.4 (− 1.4 to 0.7), 0.7 (− 0.4 to 1.8) s respectively. Conclusion Attention increases when performing BLS. Attention and dexterity are not inferior when wearing PPE, including FFP2 masks. PPE should be used on a low-threshold basis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.