Background: Many studies have used functional optical zone (FOZ) as a measure to compare different refractive laser treatment modalities. However, to our knowledge, no study has compared wavefrontoptimized (WFO) and wavefront-guided (WFG) laser in situ keratomileusis (LASIK) using FOZ. We compared the FOZ after WFO versus WFG LASIK in patients with myopia and myopic astigmatism.Methods: In this prospective comparative study, we included 100 myopic eyes of 50 patients with or without astigmatism. They were divided into two groups according to the platform used: WFO or WFG femtosecond LASIK. Using Holladay’s equivalent keratometry reading (EKR) report of Pentacam HR, FOZ was defined as a zone centered on the pupil center with a standard deviation (SD) of 0.5 D, around the mean EKR. The differences in FOZ between the two platforms were analyzed at 3 months postoperatively. Visual acuity, refractive error, corneal asphericity (Q-value), and root mean square of higher-order aberrations (RMS for HOAs) were evaluated and compared.Results: The mean ± SD of patient age was 26.64 ± 5.67 years. The preoperative characteristics of the two groups were comparable (all P > 0.05). The intended optical zone (IOZ) was 6 mm in both groups. The mean laser ablation depth was significantly greater in the WFG group (18 ?m per D) than in the WFO group (16 ?m per D) (P = 0.035). At 3 months postoperatively, the mean ± SD of FOZ diameter was 4.32 ± 0.94 mm (71.99 ± 15.68% of intended optical zone) in the WFO group and 4.16 ± 1.13 mm (69.33 ± 18.78% of intended optical zone) in the WFG group, with no significant difference between the two groups (P = 0.622). The change in corneal asphericity was greater in the WFG group than in the WFO group (P = 0.034). Postoperative mean corrected and uncorrected distance visual acuity, manifest refraction, and RMS for HOAs showed no significant difference between the two groups (all P > 0.05).Conclusions: We found that WFG LASIK resulted in greater ablation depth and change in corneal asphericity than WFO LASIK at 3 months postoperatively. However, there was no significant difference in FOZ diameter, refractive error, and RMS for HOAs between the two groups. Further research is needed to confirm these findings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.