Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer configuration allows the user to eliminate side orientation dependence, which is reported for EBT2 films. The most important EBT3 characteristics have been investigated, such as response at high‐dose levels, sensitivity to scanner orientation and postirradiation coloration, energy and dose rate dependence, and orientation dependence with respect to film side. Additionally, different IMRT fields were measured with both EBT3 and EBT2 films and evaluated using gamma index analysis. The results obtained show that most of the characteristics of EBT3 film are similar to the EBT2 film, but the orientation dependence with respect to film side is completely eliminated in EBT3 films. The study confirms that EBT3 film can be used for clinical practice in the same way as the previous EBT2 film.PACS number: 87.56.Fc
Background: Oropharyngeal mucositis occurs in virtually all patients with head and neck cancer receiving radiochemotherapy. The manipulation of the oral cavity microbiota represents an intriguing and challenging target. Patients and Methods: A total of 75 patients were enrolled to receive Lactobacillus brevis CD2 lozenges or oral care regimen with sodium bicarbonate mouthwashes. The primary endpoint was the incidence of grade 3 or 4 oropharyngeal mucositis during radiotherapy treatment. Results: There was no statistical difference in the incidence of grade 3-4 oropharyngeal mucositis between the intervention and control groups (40.6% vs. 41.6% respectively, p=0.974). The incidence of pain, dysphagia, body weight loss and quality of life were not different between the experimental and standard arm. Conclusion: Our study was not able to demonstrate the efficacy of L. brevis CD2 lozenges in preventing radiation-induced mucositis in patients with head and neck cancer. Although modulating homeostasis of the salivary microbiota in the oral cavity seems attractive, it clearly needs further study.Acute radiation-related toxicities represent a clinicallyrelevant problem during curative radiotherapy (RT) for patients with head and neck cancer (HNC). Among different side-effects, oropharyngeal mucositis (OM) remains one of the most important issues for patients with HNC, with a negative impact on their quality of life (QoL), and also on locoregional control due to the need for treatment breaks that extend the planned treatment time (1-6).The development of OM is complex and begins from clonogenic death of basal stem cells due to DNA strand breaks caused by reactive oxygen species (7). Through the complex activation of several transcription factors, it seems to end with the production of pro-inflammatory cytokines that promote and amplify cellular damage to the oral mucosa (8). Despite recent improvements in our understanding of these processes, preventive and therapeutic management of OM is still a debated and open question. A large number of 1935 This article is freely accessible online.Correspondence to:
Hypofractionated IM-WBRT with a SIB to the tumor bed delivered with TD provides consistent clinical results and it is able to reduce acute skin toxicity rate over conventionally fractionated and sequential boost tomotherapy-based IM-WBRT.
Adjuvant whole breast IMRT delivered sequentially with both TD and HT provides consistent clinical results. An observed unintended excessive dose outside the tumor bed might increase acute toxicity and eventually affect long-term clinical endpoints. The incorporation of the boost dose within the whole breast phase employing a simultaneous integrated boost (SIB) approach might mitigate this issue.
BackgroundThis study investigates the use of TomoDirectTM 3DCRT for whole breast adjuvant radiotherapy (AWBRT) that represents a very attractive treatment opportunity, mainly for radiotherapy departments without conventional Linacs and only equipped with helical tomotherapy units.MethodsPlans were created for 17 breast cancer patients using TomoDirect in 3DCRT and IMRT modality and field-in-field 3DCRT planning (FIF) and compared in terms of PTV coverage, overdosage, homogeneity, conformality and dose to OARs. The possibility to define patient-class solutions for TD-3DCRT employment was investigated, correlating OARs dose constraints to patient specific anatomic parameters.ResultsTD-3DCRT showed PTV coverage and homogeneity significantly higher than TD-IMRT and FIF. PTV conformality was significantly better for FIF, while no differences were found between TD-3DCRT and TD-IMRT. TD-3DCRT showed mean values of the OARs dosimetric endpoints significantly higher than TD-IMRT; with respect to FIF, TD-3DCRT showed values significantly higher for lung V20Gy, mean heart dose and V25Gy, while contralateral lung maximum dose and contralateral breast mean dose resulted significantly lower. The Central Lung Distance (CLD) and the maximal Heart Distance (HD) resulted as useful clinical tools to predict the opportunity to employ TD-3DCRT: positive correlations were found between CLD and both V20Gy and mean lung dose and between HD and both V25Gy and the mean heart dose. TD-3DCRT showed a significantly shorter mean beam-on time than TD-IMRT.ConclusionsThe present study showed that TD-3DCRT and TD-IMRT are two feasible and dosimetrically acceptable treatment approach for AWBRT, with an optimal PTV coverage and adequate OARs sparing. Some concerns might be raised in terms of dose to organs at risks if TD-3DCRT is applied to a general population. A correct patients clusterization according to simple quantitative anatomic measures, would help to correctly allocate patients to the appropriate treatment planning strategy in terms of target coverage, but also of normal tissue sparing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.