Background: Measurement of immature platelets was introduced into routine diagnostics by Sysmex as immature platelet fraction (IPF) some years ago and recently by Abbott as reticulated platelet fraction (rPT). Here, we compare both methods. Methods: We evaluated the precision and agreement of these parameters between Sysmex XE-5000 and Abbott CD-Sapphire in three distinct thrombocytopaenic cohorts: 30 patients with beginning thrombocytopaenia and 64 patients with recovering platelets (PLT) after chemotherapy, 16 patients with immune thrombocytopaenia (ITP) or heparin-induced thrombocytopaenia type 2 (HIT) and 110 additional normal controls. Furthermore, we analysed, how IPF/rPT differed between these thrombocytopaenic cohorts and controls. Results: Both analysers demonstrated acceptable overall precision (repeatability) of IPF/rPT with lower precision at low PLT counts. IPF/rPT artificially increased during storage of blood samples overnight. Inter-instrument comparison showed a moderate correlation (Pearson r² = 0.38) and a systematic bias of 1.04 towards higher IPFvalues with the XE-5000. IPF/rPT was highest in recovering thrombopoesis after chemotherapy and moderately increased in ITP/HIT. The normal range deduced from control samples was much narrower with CD-Sapphire (1.0%-3.8%, established here for the first time) in comparison to XE-5000 (0.8%-7.9%) leading to a smaller overlap of samples with increased PLT turnover and normal controls. Conclusions: IPF and rPT both give useful information on PLT turnover, although the two analysers only show a moderate inter-instrument correlation and have diffe rent reference ranges. A better separation of patient groups with high PLT turnover like ITP/HIT from normal controls is obtained by CD-Sapphire.
4639 Background: Quantification of immature, i.e. RNA-containing platelets (PLT) was introduced into routine diagnostics by Sysmex as immature platelet fraction (IPF) some years ago and recently by Abbott as reticulated platelets (rPLT). In this study, we evaluated the precision and agreement of both analyzers in normal and pathological samples and correlation of IPF or rPLT with clinical situations. Methods: Anonymized blood samples of cancer patients after chemotherapy, patients with PLT destruction (immune thrombocytopenia, ITP, or heparin-induced thrombocytopenia, HIT), and normal controls were analyzed with double measurements with both, the Abbott CD-Sapphire and Sysmex XE-5000. Furthermore, longitudinal evaluations after chemotherapy were performed and effects of PLT transfusions were analyzed. Precision and agreement were assessed with Bland-Altman analyses and Pearson correlation. Results: In a first set of experiments, a total of 220 blood samples were analyzed. We studied patients after chemotherapy with beginning thrombocytopenia (30 samples, median PLT count 23/nl) or recovering PLT counts (64 samples, PLT 48/nl), patients with PLT destruction (16 samples, PLT 84/nl) and normal controls (110 samples, PLT 249/nl). Both analyzers demonstrated acceptable overall precision (reproducibility) with lower precision in thrombocytopenia and a non-significant trend towards a better precision with XE-5000. Inter-instrument comparison showed a moderate correlation (Pearson r2=0.38) and a systematic bias of 1.04 towards higher IPF-values with the XE-5000 in the Bland-Altman analysis. Regarding different patient groups, the reference range (percentile 5 – 95) of normal controls was much narrower with the CD-Sapphire, leading to a clear separation of patients with recovering platelet counts after chemotherapy and IPT/HIT, both with increased rPLT as expected (figure). The same trend was visible for the XE-5000, however, with a much broader overlap to the normal range. In longitudinal studies, increased IPF or rPLT were frequently observed already during early thrombocytopenia with a decrease following platelet transfusions. Conclusion: Correlation between both analyzers for measurement of IPF and rPLT, respectively, was moderate. Precision of measurements was low in thrombocytopenic samples. Samples with abnormally increased IPF/rPLT could be indentified with both analyzers, however, separation from normal was better with the CD-Sapphire. Prediction of PLT recovery after intensive chemotherapy by the measurement of IPF/rPLT is questionable. Disclosures: Krause: Beckman Coulter: Research Funding.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.