Background and ObjectivePeri‐implantitis is a destructive inflammatory process characterized by destruction of the implant‐supporting bone. Inflammasomes are large intracellular multiprotein complexes that play a central role in innate immunity by activating the release of proinflammatory cytokines. Although inflammasome activation has previously been linked to periodontal inflammation, there is still no information on a potential association with peri‐implantitis. The aim of this study was to examine cytotoxic and proinflammatory effects, including inflammasome activation, of metals used in dental implants, in an in vitro model, as well as from clinical tissue samples.Material and methodsHuman macrophages were exposed to different metals [titanium (Ti), cobalt, chromium and molybdenum] in a cell‐culture assay. Cytotoxicity was determined using the neutral red uptake assay. Cytokine secretion was quantified using an ELISA, and the expression of genes of various inflammasome components was analysed using quantitative PCR. In addition, the concentrations of interleukin‐1β (IL‐1β) and Ti in mucosal tissue samples taken in the vicinity of dental implants were determined using ELISA and inductively coupled plasma mass spectrometry, respectively.ResultsTi ions in physiological solutions stimulated inflammasome activation in human macrophages and consequently IL‐1β release. This effect was further enhanced by macrophages that have been exposed to lipopolysaccharides. The proinflammatory activation caused by Ti ions disappeared after filtration (0.22 μm), which indicates an effect of particles. Ti ions alone did not stimulate transcription of the inflammasome components. The Ti levels of tissue samples obtained in the vicinity of Ti implants were sufficiently high (≥ 40 μm) to stimulate secretion of IL‐1β from human macrophages in vitro.ConclusionTi ions form particles that act as secondary stimuli for a proinflammatory reaction.
Over a 5-year period, technical complications in implant-supported restorative therapy occurred frequently and their management required professional intervention.
Since the discovery of osseointegration in the 1960s by Per-Ingvar Brånemark, 1 dental titanium (Ti) implants have been widely used as a standard treatment for edentulism. An estimated 5 million implants are placed annually in the United States, and a total of 15-20 million implants are placed worldwide. 2,3 Long-term follow-up studies show that implant usage to replace missing or lost teeth is a safe and predictable treatment with an overall 5-year survival rate of 98.1% for the implants and 97.1% for the prosthetics. 4 However, researchers and dentists are concerned about the rising number of published reports on inflammatory problems and bone loss around dental implants, so-called peri-implantitis. 5-8 A wide range of estimates of peri-implantitis prevalence has been reported in different studies, that is 6.2%-28% at the implant level. 9-15 Peri-implantitis is a multifactorial disease, and ongoing research is trying to identify the cause Summary Objectives: The aim of this study was to investigate the titanium (Ti) content of biopsies from patients with severe peri-implantitis or controls without Ti exposure.Background: Peri-implantitis is considered to be an infectious disease, but recent studies have shown that Ti can aggravate inflammation in combination with bacterial products. The Ti content of peri-implantitis and periodontitis (controls) tissue is unknown.Methods: Thirteen patients referred for peri-implantitis and eleven for periodontitis treatment were included in the study. Disease severity was obtained from dental records. Biopsies were taken from both groups and chemically analysed with inductively coupled plasma mass spectrometry for Ti content. Additionally, two patients with peri-implantitis and two with periodontitis were recruited and their biopsies were analysed microscopically with light microscopy, transmission electron microscopy and scanning electron microscopy with element analysis to investigate the presence of particulate Ti.Results: All patients lost one or more implants despite undergoing peri-implant or treatment. Peri-implantitis tissue contained significantly higher concentrations of Ti than control samples with a mean ± SD of 98.7 ± 85.6 and 1.2 ± 0.9 μg/g, respectively. Particulate metal was identified in peri-implantitis and control biopsies, but element analyses could confirm only the presence of Ti in peri-implantitis tissue. Conclusion:We showed that high contents of particulate and submicron Ti were present in peri-implantitis tissue. These high Ti contents in peri-implant mucosa can potentially aggravate inflammation, which might reduce the prognosis of treatment interventions. K E Y W O R D Senergy dispersive X-ray spectroscopy, inductively coupled plasma mass spectrometry, light microscopy, peri-implantitis, scanning electron microscopy, titaniumCheng Choo Lee at Umeå Core Facility Electron Microscopy, Umeå University, Sweden, for their help with the transmission and SEM.
In the present study, amount of titanium (Ti) released into the surrounding bone during placement of implants with different surface structure was investigated. Quantification of Ti released during insertion from three different implants was performed in this ex vivo study. Jaw bone from pigs was used as model for installation of the implants and Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) was used for analysis of the released Ti. Implant surface were examined with scanning electron microscopy (SEM), before and after the placement into the bone. Ti was abraded to the surrounding bone upon insertion of a dental implant and the surface roughness of the implant increased the amount of Ti found. Diameter and total area of the implant were of less importance for the Ti released to the bone. No visible damages to the implant surfaces could be identified in SEM after placement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.