Introduction: Serrated polyposis syndrome (SPS) increases colorectal cancer (CRC) risk. We describe the numbers of colonoscopies and polypectomies performed to achieve and maintain low polyp burdens, and the feasibility of expanding surveillance intervals in patients who achieve endoscopic control. Methods: We retrospectively evaluated a prospectively collected database on 115 SPS patients undergoing surveillance at Indiana University Hospital between June 2005 and May 2018. The endoscopist provided surveillance interval recommendations based on polyp burden. Endoscopic control was considered successful if surveillance examinations exhibited fewer polyps and if no or only an occasional polyp ≥1 cm in size was present at follow-up. Initial control was designated the clearing phase and the maintenance phase was surveillance after control was established. Results: In total, 87 patients (75.7%) achieved endoscopic control, with some others in the clearing phase at this writing. Achieving control required a mean of 2.84 colonoscopies (including the baseline) over 20.4 months and a mean total 27.9 polyp resections. After establishing control, 71 patients were recommended to receive ≥24-month follow-up. Of those, 60 patients (69.0% of patients with initial control) continued surveillance at our center. The mean interval between colonoscopies during maintenance was 19.3 months with 6.74 mean polypectomies per procedure on polyps primarily <1 cm. There were no incident cancers or colon surgeries during maintenance.
Objectives
To determine the safety and effectiveness of the middle cranial fossa (MCF) approach in repairing spontaneous cerebrospinal fluid (sCSF) leaks.
Study Design
Retrospective cohort study.
Methods
Patient with sCSF leaks repaired by MCF approach between January 1, 2014 and August 31, 2019 were included. Demographic information, clinical and surgical findings, and postoperative outcomes were recorded.
Results
The cohort (n = 45) included 24 tegmen repairs by multilayer reconstruction using hydroxyapatite cement and 21 cases of multilayer repair without hydroxyapatite cement. Ten MCF repairs were performed on patients ≥65 years old. Twenty (53%) ears had multiple tegmen defects (range, 1–9 tegmen defects) and 78% of patients had ≥1 encephaloceles. All sCSF leaks were resolved with one surgical intervention. There were no major intracranial complications. Transient expressive aphasia occurred in 2 patients. Medical complications occurred in four patients. There were no short‐term postoperative CSF leaks with bone cement reconstruction and two postoperative leaks without bone cement. One resolved with lumbar drain (LD) and the other resolved without treatment. The average (SD) length of stay (LOS) with bone cement was shorter than in patients without bone cement (2.54 [0.83] days vs. 3.52 [1.99] days, P < .05). There have been no long‐term CSF leak recurrences with an average (SD) follow‐up of 13.5 (12.9) months (range 0.25–46 months).
Conclusions
MCF approach for sCSF repairs demonstrate efficacious outcomes, particularly with tegmen reconstruction using hydroxyapatite cement. The approach exhibited no serious adverse events and few complications requiring intervention. Therefore, MCF is a safe and effective approach to resolve sCSF leaks.
Level of Evidence
3 Laryngoscope, 131:624–632, 2021
Background Diminutive colorectal polyps resected during colonoscopy are sometimes histologically interpreted as normal tissue. The aim of this observational study was to explore whether errors in specimen handling or processing account in part for polyps ≤ 3 mm in size being interpreted as normal tissue by pathology when they were considered high confidence adenomas by an experienced endoscopist at colonoscopy.
Methods One endoscopist photographed 900 consecutive colorectal lesions that were ≤ 3 mm in size and considered endoscopically to be high confidence conventional adenomas. The photographs were reviewed blindly to eliminate poor quality images. The remaining 644 endoscopy images were reviewed by two external experts who predicted the histology while blinded to the pathology results.
Results Of 644 consecutive lesions ≤ 3 mm in size considered high confidence conventional adenomas by a single experienced colonoscopist, 15.4 % were reported as normal mucosa by pathology. The prevalence of reports of normal mucosa in polyps removed by cold snare and cold forceps were 15.2 % and 16.0 %, respectively. When endoscopy photographs were reviewed by two blinded outside experts, the lesions found pathologically to be adenomas and normal mucosa were interpreted as high confidence adenomas by endoscopic appearance in 96.9 % and 93.9 %, respectively, by Expert 1 (P = 0.15), and in 99.6 % and 100 %, respectively, by Expert 2 (P = 0.51).
Conclusion Retrieval and/or processing of tissue specimens of tiny colorectal polyps resulted in some lesions being diagnosed as normal tissue by pathology despite being considered endoscopically to be high confidence adenomas. These findings suggest that pathology interpretation is not a gold standard for lesion management when this phenomenon is observed.
Comparing adenoma and polyp miss rates for total underwater colonoscopy versus standard CO2: a randomized controlled trial using a tandem colonoscopy approach. Gastrointestinal Endoscopy.
Background and Aims: Viscous solutions provide a superior submucosal cushion for endoscopic mucosal resection (EMR). SIC-8000 (Eleview, Aries Pharmaceuticals, La Jolla, Calif) is a commercially available FDA approved solution but hetastarch is also advocated. We performed a randomized trial comparing SIC-8000 to hetastarch as submucosal injection agents for colorectal EMR. Methods: This was a single-center double-blinded randomized controlled trial performed at a tertiary referral center. Patients were referred to our center with flat or sessile lesions measuring ≥15 mm in size. The primary outcome measures were the Sydney Resection Quotient (SRQ) and the rate of en bloc resections. Secondary outcomes were total volume needed for a sufficient lift, number of resected pieces, and adverse events. Results: There were 158 patients with 159 adenomas (84 SIC-8000 and 75 hetastarch) and 57 serrated lesions (30 SIC-8000 and 27 hetastarch). SRQ was significantly better in the SIC-8000 group compared with hetastarch group (9.3 vs 8.1, p=0.001). There was no difference in the proportion of lesions with en bloc resections. The total volume of injectate was significantly lower with SIC-8000 (14.8 mL vs 20.6 mL, p=0.038) Conclusions: SIC-8000 is superior to hetastarch for use during EMR in terms of SRQ and total volume needed, although the absolute differences were small.
Background and study aims: The adenoma detection rate (ADR) and adenomas detected per colonoscopy (APC) are measures of the quality of mucosal inspection during colonoscopy. In a resect and discard policy, pathologic assessment for calculation of ADR and APC would not be available. The aim of this study was to determine whether ADR and APC calculation based on photography alone is adequate compared with the pathology-based gold standard.
Patients and methods: A prospective, observational, proof-of-concept study was performed in an academic endoscopy unit. High definition photographs of consecutive polyps were taken, and pathology was estimated by the colonoscopist. Among 121 consecutive patients aged ??50 years who underwent colonoscopy, 268 polyps were removed from 97 patients. Photographs of consecutive polyps were reviewed by a second endoscopist.
Results: The resect and discard policy applied to lesions that were???5?mm in size. When only photographs of lesions that were ultimately proven to be adenomas were included, the reviewer assessed ADR and APC to be lower than that determined by pathology (absolute reductions of 6.6?% and 0.17, and relative reductions of 12.6?% and 13.1?% in ADR and APC, respectively). When all photographs were included for calculation of ADR and APC, the reviewer determined the ADR to be 3.3?% lower (absolute reduction) and the APC to be the same as the rates determined by pathology.
Conclusions: In a simulated resect and discard strategy, a high-level detector can document adequate ADR and APC by photography alone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.