In recent years, the International Maritime Organization agreed on aiming to reduce shipping's greenhouse gas emissions by 50% with respect to 2009 levels. Meanwhile, cruise ship tourism is growing at a fast pace, making the challenge of achieving this goal even harder. The complexity of the energy system of these ships makes them of particular interest from an energy systems perspective. To illustrate this, we analyzed the energy and exergy flow rates of a cruise ship sailing in the Baltic Sea based on measurements from one year of the ship's operations. The energy analysis allows identifying propulsion as the main energy user (46% of the total) followed by heat (27%) and electric power (27%) generation; the exergy analysis allowed instead identifying the main inefficiencies of the system: while exergy is primarily destroyed in all processes involving combustion (76% of the total), the other main causes of exergy destruction are the turbochargers, the heat recovery steam generators, the steam heaters, the preheater in the accommodation heating systems, the sea water coolers, and the electric generators; the main exergy losses take place in the exhaust gas of the engines not equipped with heat recovery devices. The application of clustering of the ship's operations based on the concept of typical operational days suggests that the use of five typical days provides a good approximation of the yearly ship's operations and can hence be used for the design and optimization of the energy systems of the ship.
This paper presents the study of a mid-sized semi-closed oxy-fuel combustion combined cycle (SCOC-CC) with net power output around 108 MW. The paper describes not only the power balance and the performance of the SCOC-CC, but also the conceptual design of the SCOC turbine and compressor. A model has been built in the commercial heat and mass balance code IPSEpro to estimate the efficiency of semi-closed dual-pressure oxy-fuel combustion combined cycle using natural gas as a fuel. In order to obtain the real physical properties of the working fluids in IPSEpro, the code was linked to the NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP). The oxy-fuel turbine was modeled with the in-house Lund University package LUAX-T. Important features such as stage loading, loss modeling, cooling and geometric features were included to generate more accurate results. The oxy-fuel compressor has been modeled using a Chalmers university in-house tool for conceptual design of axial compressors. The conceptual design of the SCOC-CC process has a net efficiency of 47%. The air separation unit and CO2 compression reduce the cycle efficiency by 10 and 2 percentage points, respectively. A single-shaft configuration was selected for the gas turbine simplicity. The rotational speed chosen was 5200 rpm and the turbine was designed with four stages. All stage preliminary design parameters are within ranges of established industrial axial turbine design limits. The main issue is the turbine exit Mach number; the stage must be lightly loaded in terms of pressure ratio to maintain the exit Mach number below 0.6. The compressor is designed with 18 stages. The current value of the product of the annulus area and the blade rotational speed squared (AN2) was calculated and found to be 40·106.
The Evaporative Gas Turbine Pilot Plant has been in operation at Lund Institute of Technology in Sweden since 1997. In this cycle low-grade heat in the flue gases is utilized for water evaporation into the compressed air in the humidification tower. This result in, amongst others, power augmentation, efficiency increase and lower emissions. This article presents the experimental and theoretical results of the humidification tower, in which simultaneous heat and mass transfer occurs. A theoretical model has been established for the simultaneous heat and mass transfer occurring in the humidification tower and it has been validated with experiments. The humidification tower in the pilot plant can be operated at several operating conditions. An after-cooler makes it possible to chill the compressor discharge air before entering the humidification tower. The saturation temperature of the incoming compressed air can thereby be varied from 62 to 105 °C at the operating pressure of 8 bar(a). It has been shown that the air and water can be calculated throughout the column in a satisfactory way. The height of the column can be estimated with an error of 10% compared with measurements. The results from the model are most sensitive of the properties of the diffusion coefficient, viscosity and thermal conductivity due to the complexity of the polar gas mixture of water and air.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.