The way to evaluate a device in charge of heat transfer under certain working conditions is through the study of the global coefficient of heat transfer, it was carried out using a test bench that includes the base unit where the heating and movement of water is carried out and a unit where the heat exchange is carried out connected by means of flexible tubes and using the fundamental equations that are required, the results obtained were respectively the global transfer coefficient for both fluids of work with their respective Nusselt number, finally it is observed that the relationships between other models for plate exchangers, the comparative error is very large (40%) and to have more concise results. the scale factor must be taken into account.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.