A new high-performance liquid chromatographic/electrospray ionization tandem mass spectrometric (HPLC/ESI-MS/MS) method was developed for the simultaneous quantification of 5-fluorouracil (5FU), methotrexate (MTX) and cyclophosphamide (CP) in environmental samples. These compounds, commonly used in the treatment of cancer, are recognized as genotoxic. In order to estimate the occupational exposure of hospital personnel handling these drugs, wipe samples were taken from the working surfaces and directly analyzed (with trophosphamide as internal standard) using a reversed-phase capillary column and MS/MS detection. This is the first HPLC/MS/MS method for the simultaneous determination of 5FU, MTX and CP. The present method offers high sensitivity, with detection limits of 1.1 microg l(-1) for MTX and CP and 33.3 microg l(-1) for 5FU, avoiding any sample preconcentration procedure. Rapidity, specificity, high accuracy (mean values between 92.4 and 99.9%) and precision (mean RSD values between 3.4 and 12.1%) make the method suitable for the routine determination of these three antineoplastic drugs.
8-Hydroxy-2'-deoxyguanosine (8OHdG), one of the major oxidative DNA lesions induced by radical agents, is commonly used as a biomarker for oxidative stress, nowadays preferably in urine. In the absence of a commercially available internal standard a micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (micro-HPLC/ESI-MS/MS) method, suitable for routine analysis of 8OHdG in human urine using external calibration, was developed. Evaluation of the matrix effect showed that the method allows highly sensitive and accurate quantitation despite the absence of an internal standard. HPLC analysis was performed using gradient elution at a flow rate of 10 microL min(-1) using a capillary reversed-phase column and an injection volume of 0.5 microL, with detection of 8OHdG in positive multiple reaction monitoring (MRM) mode. The absolute limit of detection was 0.35 fmol using m/z 168 as a quantifier (fragment) ion. A linear (R2> 0.999) calibration curve in urine was obtained over a range 0.2-10 ng mL(-1). This method is about 20 times more sensitive than previously described procedures, and is characterized by high accuracy (mean 90%) and good reproducibility (RSD <10%). The optimized method was applied to determination of 8OHdG in 18 urinary samples derived from three healthy volunteers. 8OHdG urinary excretion ranged from 3.0-7.9 microg/day, and a large intra-individual variation was found. This method, which effectively circumvents the need for isotopically labeled 8OHdG (internal standard), is suitable for routine monitoring of exposure to DNA-damaging factors in a large number of subjects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.