We aim at testing the possibility to build patientspecific structural finite element models (FEMs) of the mitral valve (MV) from cardiac magnetic resonance (CMR) imaging and to use them to predict the outcome of mitral annuloplasty procedures. MV FEMs were built for one healthy subject and for one patient with ischemic mitral regurgitation. On both subjects, CMR imaging of 18 longaxis planes was performed with a temporal resolution of 55 time-frames per cardiac cycle. Three-dimensional MV annulus geometry, leaflets surface and PM position were manually obtained using custom software. Hyperelastic anisotropic mechanical properties were assigned to MV tissues. A physiological pressure load was applied to the leaflets to simulate valve closure until peak systole. For the pathological model only, a further simulation was run, simulating undersized rigid annuloplasty before valve closure. Closure dynamics, leaflets stresses and tensions in the subvalvular apparatus in the healthy MV were consistent with previous computational and experimental data. The regurgitant valve model captured with good approximation the real size and position of regurgitant areas at peak systole, and highlighted abnormal tensions in the annular region and sub-valvular apparatus. The simulation of undersized rigid annuloplasty showed the restoration of MV continence and normal tensions in the subvalvular apparatus and at the annulus. Our method seems suitable for implementing detailed patient-specific MV FEMs to simulate different scenarios of clinical interest. Further work is mandatory to test the method more deeply, to reduce its computational time and to expand the range of modeled surgical procedures.
Recent computational methods enabling patient-specific simulations of native and prosthetic heart valves are reviewed. Emphasis is placed on two critical components of such methods: 1) anatomically realistic finite element models for simulating the structural dynamics of heart valves; and 2) fluid structure interaction methods for simulating the performance of heart valves in a patient specific beating left ventricle. It is shown that the significant progress achieved in both fronts paves the way toward clinically relevant computational models that can simulate the performance of a range of heart valves, native and prosthetic, in a patient-specific left heart environment. The significant algorithmic and model validation challenges that need to be tackled in the future to realize this goal are also discussed.
Finite element modeling represents an established method for the comprehension of the mitral function and for the simulation of interesting clinical scenarios. However, current models still do not include all the key aspects of the real system. We implemented a new structural finite element model that considers (i) an accurate morphological description of the valve, (ii) a description of the tissues' mechanical properties that accounts for anisotropy and nonlinearity, and (iii) dynamic boundary conditions that mimic annulus and papillary muscles' contraction. The influence of such contraction on valve biomechanics was assessed by comparing the computed results with the ones obtained through an auxiliary model with fixed annulus and papillary muscles. At the systolic peak, the leaflets' maximum principal stress contour showed peak values in the anterior leaflet at the strut chordae insertion zone (300 kPa) and near the annulus (200-250 kPa), while much lower values were detected in the posterior leaflet. Both leaflets underwent larger tensile strains in the longitudinal direction, while in the circumferential one the anterior leaflet experienced nominal tensile strains up to 18% and the posterior one experienced compressive strains up to 23% associated with the folding of commissures and paracommissures, consistently with tissue redundancy. The force exerted by papillary muscles at the systolic peak was equal to 4.11 N, mainly borne by marginal chordae (76% of the force). Local reaction forces up to 45 mN were calculated on the annulus, leading to tensions of 89 N/m and 54 N/m for its anterior and posterior tracts, respectively. The comparison with the results of the auxiliary model showed that annular contraction mainly affects the leaflets' circumferential strains. When it was suppressed, no more compressive strains could be observed and peak strain values were located in the belly of the anterior leaflet. Computational results agree to a great extent with experimental data from literature. They provided insight into some of the features characterizing normal mitral function, such as annular contraction and leaflets' tissue anisotropy and nonlinearity. Some of the computed results may be useful in the design of surgical devices and techniques. In particular, forces applied on the annulus by the surrounding tissues could be considered as an indication for annular prostheses design.
2Objectives: Finite element modeling was adopted to quantitatively compare, for the first time and on a 3 patient-specific basis, the biomechanical effects of a broad spectrum of different neochordal implantation 4 techniques for the repair of isolated posterior mitral leaflet prolapse.
5Methods: Cardiac magnetic resonance images were acquired on four patients undergoing surgery. The 6 patient-specific three-dimensional model of mitral apparatus, and the motion of annulus and papillary 7 muscles were reconstructed: location and extent of the prolapsing region were confirmed by intraoperative
19Conclusions: Although applied on a small cohort of patients, systematic biomechanical differences were 20 noticed between neochordal techniques, potentially affecting their short-to-long term clinical outcome.
21This study opens the way to patient-specific optimization of neochordal techniques.
The onset of thromboembolic phenomena in blood oxygenators, even in the presence of adequate anticoagulant strategies, is a relevant concern during extracorporeal circulation (ECC). For this reason, the evaluation of the thrombogenic potential associated with extracorporeal membrane oxygenators should play a critical role into the preclinical design process of these devices. This study extends the use of computational fluid dynamics simulations to guide the hemodynamic design optimization of oxygenators and evaluate their thrombogenic potential during ECC. The computational analysis accounted for both macro- (i.e., vortex formation) and micro-scale (i.e., flow-induced platelet activation) phenomena affecting the performances of a hollow-fiber membrane oxygenator with integrated heat exchanger. A multiscale Lagrangian approach was adopted to infer the trajectory and loading history experienced by platelet-like particles in the entire device and in a repetitive subunit of the fiber bundles. The loading history was incorporated into a damage accumulation model in order to estimate the platelet activation state (PAS) associated with repeated passes of the blood within the device. Our results highlighted the presence of blood stagnation areas in the inlet section that significantly increased the platelet activation levels in particles remaining trapped in this region. The order of magnitude of PAS in the device was the same as the one calculated for the components of the ECC tubing system, chosen as a term of comparison for their extensive diffusion. Interpolating the mean PAS values with respect to the number of passes, we obtained a straightforward prediction of the thrombogenic potential as a function of the duration of ECC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.