The COVID-19 pandemic started in China in early December 2019, and quickly spread around the world. The epidemic gradually started in Italy at the end of February 2020, and by May 31, 2020, 232,664 cases and 33,340 deaths were confirmed. As a result of this pandemic, the Italian Ministerial Decree issued on March 11, 2020, enforced lockdown; therefore, many social, recreational, and cultural centers remained closed for months. In Apulia (southern Italy), all non-urgent hospital activities were suspended, and some wards were closed, with a consequent reduction in the use of the water network and the formation of stagnant water. This situation could enhance the risk of exposure of people to waterborne diseases, including legionellosis. The purpose of this study was to monitor the microbiological quality of the water network (coliforms, E. coli , Enterococci, P. aeruginosa, and Legionella ) in three wards (A, B and C) of a large COVID-19 regional hospital, closed for three months due to the COVID-19 emergency. Our study revealed that all three wards' water network showed higher contamination by Legionella pneumophila sg 1 and sg 6 at T1 (after lockdown) compared to the period before the lockdown (T0). In particular, ward A at T1 showed a median value = 5600 CFU/L (range 0–91,000 CFU/L) vs T0, median value = 75 CFU/L (range 0–5000 CFU/L) ( p-value = 0.014); ward B at T1 showed a median value = 200 CFU/L (range 0–4200 CFU/L) vs T0, median value = 0 CFU/L (range 0–300 CFU/L) ( p-value = 0.016) and ward C at T1 showed a median value = 175 CFU/L (range 0–22,000 CFU/L) vs T0, median value = 0 CFU/L (range 0–340 CFU/L) ( p-value < 0.001). In addition, a statistically significant difference was detected in ward B between the number of positive water samples at T0 vs T1 for L. pneumophila sg 1 and sg 6 (24% vs 80% p-value < 0.001) and for coliforms (0% vs 64% p-value < 0.001). Moreover, a median value of coliform load resulted 3 CFU/100 ml (range 0–14 CFU/100 ml) at T1, showing a statistically significant increase versus T0 (0 CFU/100 ml) ( p-value < 0.001). Our results highlight the need to implement a water safety plan that includes staff training and a more rigorous environmental microbiological surveillance in all hospitals before occupying a closed ward for a longer than one week, according to national and international guidelines.
A Coronavirus disease (COVID-19), caused by a new virus called severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), spreads via direct contact through droplets produced by infected individuals. The transmission of this virus can also occur via indirect contact if objects and surfaces are contaminated by secretions from individuals with COVID-19 or asymptomatic carriers. Environmental contamination with SARS-CoV-2 is high in hospital settings; on the contrary, surface contamination in non-healthcare settings is still poorly studied. In this study, the presence of SARS-CoV-2 on the surfaces of 20 tourist-recreational facilities was investigated by performing a total of 100 swabs on surfaces, including refrigerator handles, handrails, counters, tables, and bathroom access doors. Six (6%) swabs from four (20%) tourist-recreational facilities tested positive for SARS-CoV-2; the surfaces that were involved were toilet door handles, refrigerator handles, handrails, and bar counters. This study highlights that SARS-CoV-2 is also present in non-healthcare environments; therefore, in order to limit this worrying pandemic, compliance with behavioral rules and the adoption of preventive and protective measures are of fundamental importance not only in healthcare or work environments but also in life environments.
Postoperative infections are a concern, especially in total knee and total hip arthroplasty. We evaluated the air quality in orthopaedic operating theatres in southeastern Italy to determine the level of bacterial contamination as a risk factor for postoperative infection. Thirty-five hospitals with operating theatres focused on total knee and total hip arthroplasty participated. We sampled the air passively and actively before surgeries began for the day (at rest) and 15 min after the surgical incision (in operation). We evaluated bacterial counts, particle size, mixed vs turbulent airflow systems, the number of doors, number of door openings during procedures and number of people in the operating theatre. We found no bacterial contamination at rest for all sampling methods, and significantly different contamination levels at rest vs in operation. We found no association between the number of people in the surgical team and bacteria counts for both mixed and turbulent airflow systems, and low bacterial loads, even when doors were always open. Overall, the air quality sampling method and type of ventilation system did not affect air quality.
Nosocomial infections cause significant morbidity and mortality worldwide, and the pathogenic organisms responsible for such infections can develop resistance to antimicrobial agents. Understanding the activity of disinfectants against clinical and environmental bacterial isolates is therefore crucial. We analysed the in vitro activity of five antimicrobial products (phenolic compounds, didecyldimethylammonium chloride (DDAC), sodium hypochlorite, isopropanol + ammonium compounds (IACs), hydrogen peroxide) against 187 bacterial strains comprising clinical isolates, as well as 30 environmental isolates of Pseudomonas aeruginosa from hospital water samples. Disk diffusion assays were employed to assess antimicrobial activity. Hydrogen peroxide was significantly more active (p < 0.0001) than the other disinfectants against all P. aeruginosa, Klebsiella pneumoniae, Enterococcus faecalis and Staphylococcus aureus strains. It was also the only disinfectant with activity against both clinical and environmental strains of P. aeruginosa. DDAC and IAC-based disinfectants were ineffective against Gram-negative strains, but showed significant activity (particularly IACs, p < 0.0001) against the Gram-positive strains. Compared with IACs, DDAC was significantly more active on E. faecalis and less active on S. aureus (p < 0.0001). Sodium hypochlorite and phenol compounds, by contrast, were inactive against all bacterial strains. The development of disinfection procedures that are effective against all microorganisms is essential for limiting the spread of nosocomial infections.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.