The high prevalence of exercise-induced pulmonary hemorrhage (EIPH) in athletic horses constitutes to be a challenge to the racing industry and a source of major concern to animal welfare. Both experimental and clinical evidence indicate that the use of autologous platelet-rich plasma (PRP) is a promising effector of repair in a variety of pulmonary conditions. The present study evaluated the effect of intrabronchial instillation of PRP on EIPH endoscopic scores from 37 Thoroughbred racehorses. Inclusion criteria were for animals to be EIPH-positive in, at least, two consecutive post-exercise endoscopic exams and to receive 250mg of furosemide IV four hours before racing. Animals were randomly assigned into 3 groups: placebo, control, and PRP instillation. All 37 Thoroughbred racehorses included had EIPH endoscopic scores pre- and post- treatment compared by statistical analysis. The bleeding score from the group receiving PRP was significantly lower than in the control and placebo groups. No adverse effects were observed in any animal during or after the experiment. It was possible to conclude that the intrabronchial instillation of autologous PRP was effective in reducing EIPH scores in racehorses receiving furosemide and that this bioproduct can be considered as a promising coadjuvant in controlling EIPH in athletic horses.
RESUMO.-[Protocolos para o preparo de plasma rico em plaquetas (PRP) em cavalos Quarto de Milha.] Este estudo comparou dois protocolos de preparo de plasma rico em plaquetas (PRP) e avaliou a associação entre dois métodos de contagem plaquetária -um manual e o outro automático através de um estudo prospectivo. Sangue venoso de oito equinos da raça Quarto de Milha foi coletado e em seguida foi centrifugado duas vezes utilizando-se dois protocolos distintos: um com descanso antes da primeira centrifugação e outro após a segunda centrifugação. A contagem plaquetária ao início, no meio e ao final dos protocolos foi realizada manualmente e pelo método automatizado, seguida de comparação entre os dois métodos. Para investigar a degranulação plaquetária ocorrida durante o preparo do PRP, o fator de crescimento vascular endotelial (VEGF) foi mensurado em cada estágio dos protocolos. O método utilizando o descanso da amostra antes da primeira centrifugação proporcionou a obtenção de um PRP mais concentrado, além de o estudo verificar que ambos os métodos de contagem plaquetária (manual e automatizado) ABSTRACT.-Miranda S., Mello Costa M.F., Rebouças N., Ramos M.T., Lessa D.A.B. & Alencar N.X. 2019. Protocols for preparation of platelet rich plasma (PRP) in Quarter Horses. Pesquisa Veterinária Brasileira 39 (8):614-621. This study compared two protocols for preparation of platelet rich plasma (PRP) and evaluated the association between manual and automated methods for platelet count using a prospective study design. Eight clinically healthy Quarter Horses had venous blood samples collected at rest. After collection, blood samples were centrifuged twice, using two different protocols including a period of sample resting, either at the start or at the end of the protocol. Platelet counting at the start of the protocol, during, and after obtaining PRP was conducted manually or with an automated counter, followed by comparison of the two methods. In order to investigate platelet degranulation during the protocol, vascular endothelial growth factor (VEGF) was measured at each preparation stage. The protocol with sample resting before centrifugation yielded a more concentrated PRP, and the study verified that both manual and automated methods are comparable and can be used interchangeably for platelet counting. VEGF concentration did not differ significantly between protocols, or among protocol stages.The results indicate that choice of protocol for PRP preparation will affect the quantity of platelets in the final product, although platelet degranulation was not observed as evidenced by the stable VEGF concentrations measured. A larger yield of non-degranulated platelets in PRP is desirable since more α-granules will be present, therefore Protocol II is recommended. Both manual and automated counts reliably allow clinicians to obtain platelet counts and the choice of utilizing a manual or automated method is unlikely to interfere with evaluation of the final PRP product.
This publication is a compilation of all Research Abstracts presented at the Ninth International Conference on Equine Exercise Physiology. Unlike previous ICEEP conferences there will not be a conference proceedings of full length manuscripts. These abstracts succinctly summarise a wide array of investigations relevant to the equine athlete, and will be useful to veterinarians and others involved in management of horses used for sport, work and competition. The abstracts encompass the topics of Applied Physiology; Biochemistry, Haematology, Endocrinology, and Thermoregulation; Cardiovascular and Respiratory; Muscle and Bone; Nutrition; Genomics, Proteomics, and Metabolomics; Biomechanics and Locomotion; as well as Physiotherapy, Rehabilitation, and Equitation science.The International Committee of ICEEP publishes these abstracts so that the most recent scientific information is available to a wide audience, including veterinarians, physiotherapists, trainers, owners and riders.The Introduction:The ability to accurately assess equine oxygen consumption (VO2) under field conditions has been limited by the need for unrestricted gas exchange.Methods: Two variations of a mask and an associated electronics control module (ECM) were designed to enable breath-by-breath measurement of airflows with two 8.0 cm diameter pneumotachometers located 7.5 cm in front of each narus and connected to differential pressure transducers mounted on the outside of the mask. The ECM was comprised of electronics for signal filtering to the flow transducers, an oxygen sensing cell, and an analog-to-digital converter all powered by a lithium-ion battery. The battery also powered a pump connected to gas sampling ports between the nares and pneumotachometers. Airflow and oxygen content of inspired and expired gases were recorded through the ECM and electronically transferred to a notebook. VO2 was determined from these recordings by an operator using a customized software analysis program. One mask encased the lower head (E). The other left the jaw free so horse could wear a bit and be ridden (R). Multiple treadmill exercise tests were undertaken by 6 horses to measure VO2max and blood gases. Each mask was worn twice and results compared to those from an open flow-through system (O) by 2-way RMANOVA (P<0.05). Utility of the system was evaluated using the intraclass correlation coefficient of 4 independent raters.Results: Blood gases and VO2max (152.0 ± 4.0 (mean ± SEM; O), 147.7 ± 4.3 (E), 150.7 ± 3.3 (R) ml/(kg.min) were not different between masks. VO2 measures were reproducible for each mask. Agreement between the 4 raters was excellent (intraclass correlation coefficient = 0.99). Conclusions:Masks capable of measuring VO2 during field exercise were developed, tested and found accurate by multiple users.Ethical Animal Research: Studies performed were approved by the Institution's Animal Care and Use Committee (protocol #3807). Sources of funding: Institutional sources. Competing interests: Washington State University has filed notice of i...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.