A description of the results for a Station Black-Out analysis for Atucha 2 Nuclear Power Plant is presented here. Calculations were performed with MELCOR 1.8.6 YV3165 Code. Atucha 2 is a pressurized heavy water reactor, cooled and moderated with heavy water, by two separate systems, presently under final construction in Argentina. The initiating event is loss of power, accompanied by the failure of four out of four diesel generators. All remaining plant safety systems are supposed to be available. It is assumed that during the Station Black-Out sequence the first pressurizer safety valve fails stuck open after 3 cycles of water release, respectively, 17 cycles in total. During the transient, the water in the fuel channels evaporates first while the moderator tank is still partially full. The moderator tank inventory acts as a temporary heat sink for the decay heat, which is evacuated through conduction and radiation heat transfer, delaying core degradation. This feature, together with the large volume of the steel filler pieces in the lower plenum and a high primary system volume to thermal power ratio, derives in a very slow transient in which RPV failure time is four to five times larger than that of other German PWRs.
There is a global trend toward intensive livestock breeding, which tends to increase the microbial load in the environment as well as the presence of volatile compounds and dust that can cause health issues. Cattle is the major producer of Escherichiacoli (E. coli), a group of foodborne bacteria associated with severe human diseases, and Neuquén province in Argentina has one of the highest rates of uremic hemolytic syndrome incidence in the world. This paper presents the results of two sampling events of E. coli bacteria at 39 sites in La Paisana ranch (LPR), in Añelo (Neuquén), considering locations inside the pens, upwind, and downwind of the feedlot with different time steps, using a Microflow α equipment. The ranch has approximately 600 heads and clean and controlled installations. The field experiment included sampling airborne aerosol deposition and concentration using passive and active methods. Concentrations were also estimated using an atmospheric dispersion model. During the field experiment, counts of up to 2970 CFU/m3 were obtained in the cattle stockyards and up to 111 CFU/m3 at a distance of 100 m.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations –citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.