Purpose To report our preliminary experience with the use of intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (DW-MRI) and dynamic contrast-enhanced (DCE)-MRI alone and in combination for the diagnosis of liver cirrhosis. Materials and Methods Thirty subjects (16 with noncirrhotic liver, 14 with cirrhosis) were prospectively assessed with IVIM DW-MRI (n = 27) and DCE-MRI (n = 20). IVIM parameters included perfusion fraction (PF), pseudodiffusion coefficient (D*), true diffusion coefficient (D), and apparent diffusion coefficient (ADC). Model-free DCE-MR parameters included time to peak (TTP), upslope, and initial area under the curve at 60 seconds (IAUC60). A dual input single compartmental perfusion model yielded arterial flow (Fa), portal venous flow (Fp), arterial fraction (ART), mean transit time (MTT), and distribution volume (DV). The diagnostic performances for diagnosis of cirrhosis were evaluated for each modality alone and in combination using logistic regression and receiver operating characteristic analyses. IVIM and DCE-MR parameters were compared using a generalized estimating equations model. Results PF, D*, D, and ADC values were significantly lower in cirrhosis (P = 0.0056–0.0377), whereas TTP, DV, and MTT were significantly increased in cirrhosis (P = 0.0006–0.0154). There was no correlation between IVIM- and DCE-MRI parameters. The highest Az (areas under the curves) values were observed for ADC (0.808) and TTP-DV (0.952 for each). The combination of ADC with DV and TTP provided 84.6% sensitivity and 100% specificity for diagnosis of cirrhosis. Conclusion The combination of DW-MRI and DCE-MRI provides an accurate diagnosis of cirrhosis.
Purpose: To compare single-shot echo-planar imaging (SS EPI) diffusion-weighted MRI (DWI) of abdominal organs between 1.5 Tesla (T) and 3.0T in healthy volunteers in terms of image quality, apparent diffusion coefficient (ADC) values, and ADC reproducibility. Materials and Methods:Eight healthy volunteers were prospectively imaged in this HIPAA-compliant IRBapproved study. Each subject underwent two consecutive scans at both 1.5 and 3.0T, which included breathhold and free-breathing DWI using a wide range of b-values (0 to 800 s/mm 2 ). A blinded observer rated subjective image quality (maximum score¼ 8), and a separate observer placed regions of interest within the liver, renal cortices, pancreas, and spleen to measure ADC at each field strength. Paired Wilcoxon tests were used to compare abdominal DWI between 1.5T and 3.0T for specific combinations of organs, b-values, and acquisition techniques.Results: Subjective image quality was significantly lower at 3.0T for all comparisons (P ¼ 0.0078-0.0156). ADC values were similar at 1.5T and 3.0T for all assessed organs, except for lower liver ADC at 3.0T using b0-500-600 and breathhold technique. ADC reproducibility was moderate at both 1.5T and 3.0T, with no significant difference in coefficient of variation of ADC between field strengths. Conclusion:Compared with 1.5T, SS EPI at 3.0T provided generally similar ADC values, however, with worse image quality. Further optimization of abdominal DWI at 3.0T is needed.
OBJECTIVE The objective of our study was to report our initial experience with dynamic contrast-enhanced MRI (DCE-MRI) for perfusion quantification of hepatocellular carcinoma (HCC) and surrounding liver. SUBJECTS AND METHODS DCE-MRI of the liver was prospectively performed on 31 patients with HCC (male-female ratio, 26:5; mean age, 61 years; age range, 41–83 years). A dynamic coronal 3D FLASH sequence was performed at 1.5 T before and after injection of gadolinium-based contrast agent with an average temporal resolution of 3.8 seconds. Regions of interest were drawn on the abdominal aorta, portal vein, liver parenchyma, and HCC lesions by two observers in consensus. Time-activity curves were analyzed using a dual-input single-compartment model. The following perfusion parameters were obtained: arterial flow, portal venous flow, arterial fraction, distribution volume, and mean transit time (MTT). RESULTS Thirty-three HCCs (mean size, 3.9 cm; range, 1.1–12.6 cm) were evaluated in 26 patients. When compared with liver parenchyma, HCC showed significantly higher arterial hepatic blood flow and arterial fraction (p < 0.0001) and significantly lower distribution volume and portal venous hepatic blood flow (p < 0.0001–0.023), with no difference in MTT. Untreated HCCs (n = 16) had a higher arterial fraction and lower portal venous hepatic blood flow value than chemoembolized HCCs (n = 17, p < 0.04). CONCLUSION DCE-MRI can be used to quantify perfusion metrics of HCC and liver parenchyma and to assess perfusion changes after HCC chemoembolization.
SUMMARY:CT angiography is a widely used technique for the noninvasive evaluation of neurovascular pathology. Because CTA is a snapshot of arterial contrast enhancement, information on flow dynamics is limited. Dynamic CTA techniques, also referred to as 4D-CTA, have become available for clinical practice in recent years. This article provides a description of 4D-CTA techniques and a review of the available literature on the application of 4D-CTA for the evaluation of intracranial vascular malformations and hemorrhagic and ischemic stroke. Most of the research performed to date consists of observational cohort studies or descriptive case series. These studies show that intracranial vascular malformations can be adequately depicted and classified by 4D-CTA, with DSA as the reference standard. In ischemic stroke, 4D-CTA better estimates thrombus burden and the presence of collateral vessels than conventional CTA. In intracranial hemorrhage, 4D-CTA improves the detection of the "spot" sign, which represents active ongoing bleeding.ABBREVIATIONS: dAVF ϭ dural arteriovenous fistula; TI-CTA ϭ timing-invariant CTA
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.