The aim of this study was to evaluate the inferior alveolar nerve’s (IAN) intraosseous position within the inferior alveolar canal (IAC) using a 3D double-echo steady-state MRI sequence (3D-DESS). The IAN position was prospectively evaluated in 19 patients undergoing mandibular third molar (MTM) surgery. In the coronal reference layer, the IAC was divided into six segments. These segments were checked for the presence of hyperintense tubular MRI signals representing the IAN’s nervous tissue and assessed as visible/non-visible. Furthermore, the IAN in MRI and the IAC in MRI and CBCT were segmented at the third and second molar, determining the maximum diameter in all planes and a conversion factor between the imaging modalities. Regardless of the positional relationship at the third and second molar, the IAN showed the highest localization probability in the central segments (segment 2: 97.4% vs. 94.4%, segment 5: 100% vs. 91.6%). The conversion factors from IAC in CBCT and MRI to IAN in MRI, respectively, were the following: axial (2.04 ± 1.95, 2.37 ± 2.41), sagittal (1.86 ± 0.96, 1.76 ± 0.74), and coronal (1.26 ± 0.39, 1.37 ± 0.25). This radiation-free imaging modality, demonstrating good feasibility of accurate visualization of nervous tissue within the nerve canal’s osseous boundaries, may benefit preoperative assessment before complex surgical procedures are performed near the IAC.
The comparison revealed a clear advantage in favor of T2-weighted MRI at 3.0T vs. 1.5T in depicting the roots and course of brain nerves in the posterior fossa.
We investigated the reliability of assessing a positional relationship between the inferior alveolar nerve (IAN) and mandibular third molar (MTM) based on CBCT, 3D-DESS MRI, and CBCT/MRI image fusion. Furthermore, we evaluated qualitative parameters such as inflammatory processes and imaging fusion patterns. Therefore, two raters prospectively assessed in 19 patients with high-risk MTM surgery cases several parameters for technical image quality and diagnostic ability using modified Likert rating scales. Inter- and intra-reader agreement was evaluated by performing weighted kappa analysis. The inter- and intra-reader agreement for the positional relationship was moderate (κ = 0.566, κ = 0.577). Regarding the detectability of inflammatory processes, the agreement was substantial (κ = 0.66, κ = 0.668), with MRI providing a superior diagnostic benefit regarding early inflammation detection. Independent of the readers’ experience, the agreement of judgment in 3D-DESS MRI was adequate. Black bone MRI sequences such as 3D-DESS MRI providing highly confidential preoperative assessment in MTM surgery have no significant limitations in diagnostic information. With improved cost and time efficiency, dental MRI has the potential to establish itself as a valid alternative in high-risk cases compared to CBCT in future clinical routine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.