OBJECTIVES
The purpose of this study was to describe pre- and postoperative data from the EUROMACS registry with regard to indications, for and survival and complication rates of patients with primary continuous flow and pulsatile biventricular long-term assist devices (BiVADs) versus total artificial hearts (TAHs) or left ventricular assist devices (LVADs) + short-term right ventricular assist device (RVAD) implants.
METHODS
We investigated patients who received implants between 1 January 2011 and 21 October 2017. Clinical baseline information about comorbidities, laboratory results, medical and device therapies and echocardiographic, haemodynamic and right ventricle (RV) parameters were evaluated along with the rates of deaths and complications.
RESULTS
A total of 413 of 3282 patients (12.5%) needed a biventricular pump. We investigated 37 long-term BiVADs, 342 LVAD + short-term RVAD implants and 34 TAHs. Minor differences were found in the baseline characteristics of our population, which had an overall high morbidity profile. The 1-year survival rate was 55% for patients with a continuous flow BiVAD; 52% for patients with an LVAD + short-term RVAD; 37% for patients with pulsatile BiVADs; and 36% for patients with a TAH. No statistical difference was observed among the groups. Over 50% of patients with BiVAD support were classified as INTERMACS profiles 1 and 2. The percent of patients with ambulatory heart failure (INTERMACS 4‒7) undergoing BiVAD implants was modest at <15%. No patients with a pulsatile BiVAD (n = 15) or a TAH (n = 34) were implanted as destination therapy, but 27% of the patients with continuous flow BiVADs (n = 6) and 23% of the patients with LVAD + short-term RVAD (n = 342) were implanted as ‘destination’. The adverse events profile remained high, with no significant difference among pump types. The right ventricular stroke work index and right heart failure scores indicated poor RV function in all groups. After 3 months of LVAD + short-term RVAD support, 46.7% still required ongoing support, and only 18.5% were weaned from RVAD support; 33.1% died.
CONCLUSIONS
The mortality rate after BiVAD support was high. Survival rates and adverse events were statistically not different among the investigated groups. In the future, composite study end points examining quality of life and adverse events beyond survival may help in shared decision-making prior to general mechanical circulatory support, particularly in patients with BiVAD implants.
In this study, apoptosis could not be detected in the failing myocardium owing to idiopathic dilated cardiomyopathy. In contrast, failing myocardium was characterized by active DNA repair that was associated with elevated LV wall stress and activation of the inducible NO synthase.
The use of yew leaves (Taxus Baccata) as a means of deliberate self-harm is infrequent. The potent effect of the toxin is primarily cardiac and results in rhythm alterations and ultimately ventricular fibrillation. As there is no known antidote, and classic antiarrhythmic therapy proves to be ineffective, a prompt diagnosis is of great importance as immediate supportive action is the only valuable alternative. This case describes a 43-year-old women who attempted suicide by ingesting the leaves of Taxus Baccata. We discuss the effects and the difficulty of treatment associated with yew leaf poisoning.
OBJECTIVES
In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era.
METHODS
Procedures in adult patients (January 2011–June 2020) were included. Patients from centres with <60% follow-ups completed were excluded. Outcomes were stratified into 3 eras (2011–2013, 2014–2017 and 2018–2020). Adverse event rates (AERs) were calculated and stratified into early phase (<3 months) and late phase (>3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (<3 vs >3 months).
RESULTS
In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3–2.6) years. The annual number of implants (range: 346–600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4–7: 23, 25 and 33%; P < 0.001) and in-hospital deaths (18.5, 17.2 and 11.2; P < 0.001) decreased significantly between eras. Overall, mortality, transplants and the probability of weaning were 55, 25 and 2% at 5 years after the implant, respectively. Major infections were mainly noted early after the implant occurred (AER<3 months: 1.44 vs AER>3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant.
CONCLUSIONS
In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent.
Meeting the prespecified safety objective of this study warrants a randomised trial to fully evaluate the potential of home monitoring by this miniature PA implant in guiding long-term management in CHF.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.