Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology.
IMPORTANCEAlthough current guidelines suggest the use of regional citrate anticoagulation (which involves the addition of a citrate solution to the blood before the filter of the extracorporeal dialysis circuit) as first-line treatment for continuous kidney replacement therapy in critically ill patients, the evidence for this recommendation is based on few clinical trials and meta-analyses.OBJECTIVE To determine the effect of regional citrate anticoagulation, compared with systemic heparin anticoagulation, on filter life span and mortality. DESIGN, SETTING, AND PARTICIPANTSA parallel-group, randomized multicenter clinical trial in 26 centers across Germany was conducted between March 2016 and December 2018 (final date of follow-up, January 21, 2020). The trial was terminated early after 596 critically ill patients with severe acute kidney injury or clinical indications for initiation of kidney replacement therapy had been enrolled. INTERVENTIONSPatients were randomized to receive either regional citrate anticoagulation (n = 300), which consisted of a target ionized calcium level of 1.0 to 1.40 mg/dL, or systemic heparin anticoagulation (n = 296), which consisted of a target activated partial thromboplastin time of 45 to 60 seconds, for continuous kidney replacement therapy. MAIN OUTCOMES AND MEASURESCoprimary outcomes were filter life span and 90-day mortality. Secondary end points included bleeding complications and new infections. RESULTS Among 638 patients randomized, 596 (93.4%) (mean age, 67.5 years; 183 [30.7%] women) completed the trial. In the regional citrate group vs systemic heparin group, median filter life span was 47 hours (interquartile range [IQR], 19-70 hours) vs 26 hours (IQR, 12-51 hours) (difference, 15 hours [95% CI, 11 to 20 hours]; P < .001). Ninety-day all-cause mortality occurred in 150 of 300 patients vs 156 of 296 patients (Kaplan-Meier estimator percentages, 51.2% vs 53.6%; unadjusted difference, -2.4% [95% CI, -10.5% to 5.8%]; unadjusted hazard ratio, 0.91 [95% CI, 0.72 to 1.13]; unadjusted P = .38; adjusted difference, -6.1% [95% CI, -12.6% to 0.4%]; primary adjusted hazard ratio, 0.79 [95% CI, 0.63 to 1.004]; primary adjusted P = .054). Of 38 prespecified secondary end points, 34 showed no significant difference. Compared with the systemic heparin group, the regional citrate group had significantly fewer bleeding complications (15/300 [5.1%] vs 49/296 [16.9%]; difference, -11.8% [95% CI, -16.8% to -6.8%]; P < .001) and significantly more new infections (204/300 [68.0%] vs 164/296 [55.4%]; difference, 12.6% [95% CI, 4.9% to 20.3%]; P = .002).CONCLUSIONS AND RELEVANCE Among critically ill patients with acute kidney injury receiving continuous kidney replacement therapy, anticoagulation with regional citrate, compared with systemic heparin anticoagulation, resulted in significantly longer filter life span. The trial was terminated early and was therefore underpowered to reach conclusions about the effect of anticoagulation strategy on mortality.
Potential applications in the future as well as limitations of EIT technology are described. In summary, EIT is a promising functional tomography technology on the verge of its clinical application.
Acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) are syndromes of acute diffuse damage to the pulmonary parenchyma by a variety of local or systemic insults. Increased alveolar capillary membrane permeability was recognized as the common end organ injury and a central feature in all forms of ALI/ARDS. Although great strides have been made in understanding the pathogenesis of ALI/ARDS and in intensive care medicine, the treatment approach to ARDS is still relying on ventilatory and cardiovascular support based on the recognition of the clinical picture. In the course of evaluating novel treatment approaches to ARDS, 3 models of ALI induced in different species, i.e. the surfactant washout lavage model, the oleic acid intravenous injection model and the endotoxin injection model, were widely used. This review gives an overview of the pathological characteristics of these models from studies in pigs, dogs or sheep. We believe that a good morphological description of these models, both spatially and temporally, will help us gain a better understanding of the real pathophysiological picture and apply these models more accurately and liberally in evaluating novel treatment approaches to ARDS.
Breathing moves volumes of electrically insulating air into and out of the lungs, producing conductivity changes which can be seen by electrical impedance tomography (EIT). It has thus been apparent, since the early days of EIT research, that imaging of ventilation could become a key clinical application of EIT. In this paper, we review the current state and future prospects for lung EIT, by a synthesis of the presentations of the authors at the 'special lung sessions' of the annual biomedical EIT conferences in 2009-2011. We argue that lung EIT research has arrived at an important transition. It is now clear that valid and reproducible physiological information is available from EIT lung images. We must now ask the question: How can these data be used to help improve patient outcomes? To answer this question, we develop a classification of possible clinical scenarios in which EIT could play an important role, and we identify clinical and experimental research programmes and engineering developments required to turn EIT into a clinically useful tool for lung monitoring.
Gravity-dependent changes of regional lung function were studied during normogravity, hypergravity, and microgravity induced by parabolic flights. Seven healthy subjects were followed in the right lateral and supine postures during tidal breathing, forced vital capacity, and slow expiratory vital capacity maneuvers. Regional 1) lung ventilation, 2) lung volumes, and 3) lung emptying behavior were studied in a transverse thoracic plane by functional electrical impedance tomography (EIT). The results showed gravity-dependent changes of regional lung ventilation parameters. A significant effect of gravity on regional functional residual capacity with a rapid lung volume redistribution during the gravity transition phases was established. The most homogeneous functional residual capacity distribution was found at microgravity. During vital capacity and forced vital capacity in the right lateral posture, the decrease in lung volume on expiration was larger in the right lung region at all gravity phases. During tidal breathing, the differences in ventilation magnitudes between the right and left lung regions were not significant in either posture or gravity phase. A significant nonlinearity of lung emptying was determined at normogravity and hypergravity. The pattern of lung emptying was homogeneous during microgravity.
Abstract-Electrical Impedance Tomography (EIT) is a lowcost, non-invasive and radiation free medical imaging modality for monitoring ventilation distribution in the lung. Although such information could be invaluable in preventing ventilatorinduced lung injury in mechanically ventilated patients, clinical application of EIT is hindered by difficulties in interpreting the resulting images. One source of this difficulty is the frequent use of simple shapes which do not correspond to the anatomy to reconstruct EIT images. The mismatch between the true body shape and the one used for reconstruction is known to introduce errors, which to date have not been properly characterized. In the present study we therefore seek to 1) characterize and quantify the errors resulting from a reconstruction shape mismatch for a number of popular EIT reconstruction algorithms and 2) develop recommendations on the tolerated amount of mismatch for each algorithm. Using real and simulated data, we analyze the performance of 4 EIT reconstruction algorithms under different degrees of shape mismatch. Results suggest that while slight shape mismatch is well tolerated by all algorithms, using a circular shape severely degrades their performance.
Lung and cardiovascular monitoring applications of electrical impedance tomography (EIT) require localization of relevant functional structures or organs of interest within the reconstructed images. We describe an algorithm for automatic detection of heart and lung regions in a time series of EIT images. Using EIT reconstruction based on anatomical models, candidate regions are identified in the frequency domain and image-based classification techniques applied. The algorithm was validated on a set of simultaneously recorded EIT and CT data in pigs. In all cases, identified regions in EIT images corresponded to those manually segmented in the matched CT image. Results demonstrate the ability of EIT technology to reconstruct relevant impedance changes at their anatomical locations, provided that information about the thoracic boundary shape (and electrode positions) are used for reconstruction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.