Magnetic confinement nuclear fusion is an important way to realize controllable nuclear fusion. Due to the large current and complicated coil arrangement, there is a complicated electromagnetic environment around the fusion device. In this paper, the B-dot sensor is used to measure the magnetic field, the D-dot sensor is used to measure the electric field, the MAXWELL electromagnetic simulation software is used to simulate the electromagnetic field strength; the simulation and measurement of the spherical Tokamak SUNIST device and the measurement of MARX generator are carried out, then we give corresponding electromagnetic protection suggestions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.