Exhaled breath is coming to the forefront of non-invasive biomarker discovery efforts. Concentration of exhaled breath volatile organic compounds (VOCs) on thermal desorption (TD) tubes with subsequent analysis by gas chromatography-mass spectrometry (GC-MS) has dominated this field. As discovery experimentation increases in frequency, the need to evaluate the long-term storage stability of exhaled breath VOCs on thermal desorption adsorbent material is critical. To address this gap, exhaled breath was loaded on Tenax TA thermal desorption tubes and stored at various temperature conditions. 74 VOCs, 56 of which have been previously uncharacterized, were monitored using GC-MS over a period of 31 d. The results suggest that storage of exhaled breath at cold temperatures (4 °C) provides the most consistent retention of exhaled breath VOCs temporally. Samples were determined to be stable up to 14 d across storage conditions prior to gaining or losing 1-2 standard deviations in abundance. Through gene set enrichment analysis (GSEA), certain chemical classes were found to be positively (acids) or negatively (sulfur-containing) enriched temporally. By means of field sample collections, the effect of storage and shipping was found to be similar to those studies preformed in the laboratory at 4 °C. Collectively this study not only provides recommendations for proper storage conditions and storage length, but also illustrates the use of GSEA to exhaled breath based GC-MS data.
Pilots have reported experiencing in-flight hypoxic-like symptoms since the inception of high-altitude aviation. As a result, the need to monitor pilots, in-flight, for the onset of hypoxic conditions is of great interest to the aviation community. We propose that exhaled breath is an appropriate non-invasive medium for monitoring pilot hypoxic risk through volatile organic compound (VOC) analysis. To identify changes in the exhaled breath VOCs produced during periods of reduced O2 levels, volunteers were exposed to simulated flight profiles, i.e. sea level for 5 min, O2 levels found at elevated altitudes for 5 min or placebo and 5 min at 100% O2 recovery gas, using a modified flight mask interfaced with a reduced O2 breathing device. During the course of these test events, time series breath samples from the flight mask and pre/post bag samples were collected and analyzed by gas chromatography/mass spectrometry (GC/MS). Seven compounds (pentanal, 4-butyrolactone, 2-pentanone, 2-hexanone, 2-cyclopenten-1-one, 3-methylheptane and 2-heptanone) were found to significantly change in response to hypoxic conditions. Additionally, the isoprene, 2-methyl-1,3-butadiene, was found to increase following the overall exposure profile. This study establishes an experimental means for monitoring changes in VOCs in response to hypoxic conditions, a computational workflow for compound analysis via the Metabolite Differentiation and Discovery Lab and MatLab(©) software and identifies potential volatile organic compound biomarkers of hypoxia exposure.
Due to several sources of potential variability associated with exhaled breath bag sampling procedures for off-line analysis, the Respiration Collector for in vitro Analysis (ReCIVA) sampler was developed. Although designed to improve upon several pitfalls of sampling with exhaled breath bags, the ReCIVA remains a minimally studied research tool. In this manuscript, several attributes of the ReCIVA sampler are investigated among three individual tests, such as background contamination, control software version, performance of different adsorbent tubes, duplicate sample production, and comparison to exhaled breath bags. The data shows greater than a 58% reduction in background siloxanes can be achieved with submersion of ReCIVA masks in ethyl alcohol or baking the masks at a high temperature (200 °C). The results illustrate the ReCIVA control software version plays a key role in the flow rates applied to thermal desorption (TD) tubes. Using exhaled isoprene as a representative analyte, the data suggest duplicate samples among ReCIVA pump banks can be achieved using two different thermal desorption tubes, Tenax TA and Tenax/Carbograph 5TD, when using an updated control software and manually calibrating the ReCIVA pumps to uniform flow rates (Tenax p = 0.3869, 5TD p = 0.3131). Additionally, using the updated control software and manual ReCIVA flow calibration, the data suggest the ReCIVA can produce statistically similar results among TD tube types (p = 0.3824) and compared to standard exhaled breath bags (p = 0.1534). Collectively, these results establish a method for manually calibrating the flow of the ReCIVA device to allow for the most consistent results. These data support further experimentation into the use of the ReCIVA sampler for exhaled breath research.
Treatment of p-tert-butylcalix [4]arene with dichlorodimethylsilane yields a single product, p-tert-butylcalix [4]areneSiMe 2 (OH) 2 (4), in which one dimethylsilyl group bridges adjacent oxygens. Subsequent treatment of 4 with butyllithium and methyl trifluoromethanesulfonate yields two products, p-tert-butylcalix [4]arene(SiMe 2 ) 2 (5) and a lithium triflate complex of p-tert-butylcalix [4]arene(OMe) 4 , 6‚LiO 3 SCF 3 . No evidence is found for the expected product p-tert-butylcalix[4]areneSiMe 2 (OMe) 2 ( 7). This can be viewed as a formal disproportionation reaction of 7, although the mechanism of the formation of 5 and 6 likely does not involve initial formation of 7. A large difference in the 1 H NMR resonances for the nonequivalent methylsilyl groups in both 4 and 5 is found. This is attributed to the proximity of one methyl group to the π system of the aromatic rings of the calix[4]arene backbone. The structures of 4 and 5 were determined by X-ray diffraction.
Monitoring volatile organic compounds (VOCs) from exhaled breath has been used to determine exposures of humans to chemicals. Prior to analysis of VOCs, breath samples are often collected with canisters or bags and concentrated. The Bio-VOC breath sampler, a commercial sampling device, has been recently introduced to the market with growing use. The main advantage for this sampler is to collect the last portion of exhaled breath, which is more likely to represent the air deep in the lungs. However, information about the Bio-VOC sampler is somewhat limited. Therefore, we have thoroughly evaluated the sampler here. We determined the volume of the breath air collected in the sampler was approximately 88 mL. When sampling was repeated multiple times, with the succeeding exhalations applied to a single sorbent tube, we observed linear relationships between the normalized peak intensity and the number of repeated collections with the sampler in many of the breath VOCs detected. No moisture effect was observed on the Tenax sorbent tubes used. However, due to the limitation in the collection volume, the use of the Bio-VOC sampler is recommended only for detection of VOCs present at high concentrations unless repeated collections of breath samples on the sampler are conducted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.