PurposeTo study outcome and toxicity in 59 patients with locally advanced cervix carcinoma treated with computed tomography (CT)-based Martinez universal perineal interstitial template (MUPIT) and the new magnetic resonance imaging (MRI)-compatible template Benidorm (TB).Material and methodsFrom December 2005 to October 2015, we retrospectively analyzed 34 patients treated with MUPIT and 25 treated with the TB. Six 4 Gy fractions were prescribed to the clinical target volume (CTV) combined with external beam radiotherapy (EBRT). The organs at risk (OARs) and the CTV were delineated by CT scan in the MUPIT implants and by MRI in the TB implants. Dosimetry was CT-based for MUPIT and exclusively MRI-based for TB. Dose values were biologically normalized to equivalent doses in 2 Gy fractions (EQD2).ResultsMedian CTV volumes were 163.5 cm3 for CT-based MUPIT (range 81.8-329.4 cm3) and 91.9 cm3 for MRI-based TB (range 26.2-161 cm3). Median D90 CTV (EBRT + BT) was 75.8 Gy for CT-based MUPIT (range 69-82 Gy) and 78.6 Gy for MRI-based TB (range 62.5-84.2 Gy). Median D2cm3 for the rectum was 75.3 Gy for CT-based MUPIT (range 69.8-132.1 Gy) and 69.9 Gy for MRI-based TB (range 58.3-83.7 Gy). Median D2cm3 for the bladder was 79.8 Gy for CT-based MUPIT (range 71.2-121.1 Gy) and 77.1 Gy for MRI-based TB (range 60.5-90.8 Gy). Local control (LC) was 88%. Overall survival (OS), disease free survival (DFS), and LC were not statistically significant in either group. Patients treated with CT-based MUPIT had a significantly higher percentage of rectal bleeding G3 (p = 0.040) than those treated with MRI-based TB, 13% vs. 2%.ConclusionsTemplate Benidorm treatment using MRI-based dosimetry provides advantages of MRI volume definition, and allows definition of smaller volumes that result in statistically significant decreased rectal toxicity compared to that seen with CT-based MUPIT treatment.
Patients with head and neck cancers can develop salivary hypofunction after radiotherapy. The use of pilocarpine during radiotherapy treatment has been shown to be an effective treatment, although its usefulness is being discussed. The aim of this study was: (1) to determine the value of a semiquantitative scintigraphy method for measuring the uptake and excretory salivary function of patients with head and neck irradiated tumours; and (2) to study the usefulness of pilocarpine as a salivary gland protector during radiotherapy. We prospectively studied 49 patients (mean age 61 years, range 29-87 years) with head and neck cancer in need of radiotherapy. Patients were divided into two groups consecutively: group P (26 patients) received 5 mg of pilocarpine three times per day starting the day before radiation therapy, and group NP (23 patients) received radiotherapy without pilocarpine and were used as the control group. Salivary gland scintigraphy and a visual analogue scale (VAS) of mouth dryness were obtained from each patient before radiotherapy and during the first year after treatment. The most frequent finding after radiotherapy was a quick impairment in parotid and submaxillary excretion (P < 0.001). There were no statistical differences comparing the pilocarpine group against the non-pilocarpine group. Parotid and submaxillary uptake significantly decreased after radiotherapy in both groups (P < 0.001). However, a tendency to recover within the pilocarpine group was observed in both the parotids and the submaxillary glands at 12 months. No differences were found comparing the VAS results in both groups. Strikingly, VAS data did not correlate with salivary gland dysfunction observed by means of scintigraphy. In conclusion, salivary scintigraphy is a useful technique to evaluate objectively the salivary gland function of patients with head and neck irradiated tumours as well as to test the response to pilocarpine. However, despite better results on the salivary uptake at 12 months, pilocarpine did not significantly improve salivary gland function.
PurposeTo describe the potential clinical use of a new brachytherapy applicator for gynecological tumors, with special attention to locally advanced cervical carcinoma. This device allows the combination of intracavitary radiotherapy and MRI-compatible transperineal interstitial needles. The design of this template addresses the disadvantages of currently commercially available templates: the inability of the intracavitary component to reach deep into the cervix (MUPIT), and the MRI-incompatibility of these templates (MUPIT and Syed), which necessitates use of CT imaging for the dosimetry.Material and methodsThe newly developed Benidorm Template applicator allows titanium needles in a template with straight and angled holes to provide different angles of divergence to be used with currently existing MRI-compatible intrauterine tubes. It can provide total coverage of the craniocaudal and lateral extension of the tumor (intrautherus, parametrial, and paravaginal). This method is mainly indicated in advanced cervical carcinoma with bulky parametrial invasion (medial or distal), with bulky primary disease that responds poorly to external beam radiotherapy extensive paravaginal involvement (tumor thickness greater than 0.5 cm) extending to the middle or lower third of the vagina, or for disease that has invaded the bladder or rectum (stage IVA).ResultsBetween April 2013 until December 2014, we treated 15 patients with locally advanced cervical carcinoma employing the Benidorm Template. The median dose at D90 for the CTV was 79.8 Gy (71.5-89.9 Gy), at D2cc for the bladder it was 77.6 Gy (69.8-90.8 Gy), and at D2cc for the rectum it was 71.9 Gy (58.3-83.7 Gy). Values expressed in EQD2, assuming α/β of 10 for CTV and 3 for OAR.ConclusionsThis new applicator allows the use of MRI-based dosimetry, thus providing the advantages of MRI volume definition. As such, it facilitates determination of complete intracavitary and interstitial CTV coverage and the sparing of normal tissues.
PurposeEsteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the positioning of the applicator. These templates are freely available upon request.Material and methodsTemplates that were developed by University and Polytechnic Hospital La Fe (La Fe) and Hospital Clínica Benidorm (ITIC) in cooperation with Elekta, consist of a thin sheet made of transparent acrylic. For each applicator, a crosshair and two different circles are drawn on these templates: the inner one corresponds to the useful beam, while the outer one represents the external perimeter of the applicator. The outer circle contains slits that facilitate to draw a circle on the skin of the patient for exact positioning of the applicator. In addition, there are two perpendicular rulers to define the adequate margin. For each applicator size, a specific template was developed.ResultsThe templates have been used successfully in our institutions for more than 50 patients’ brachytherapy treatments. They are currently being used for Esteya and Valencia applicators.ConclusionsThe template La Fe-ITIC is simple and practical. It improves both the set-up time and reproducibility. It helps to establish the adequate margins, an essential point in the clinical outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.