Using the actual K values with a target of low myopia is a suitable option for spherical IOL selection for eyes with a mean K of ≤55 D. When there is severe keratoconus, the use of actual K values can result in a large hyperopic error and the use of standard K value in these eyes should be considered.
Corneal transplantation is the only treatment available to restore vision for individuals with blindness due to corneal endothelial dysfunction. However, severe shortage of available donor corneas remains a global challenge. Functional regulatory compliant tissue-engineered corneal endothelial graft substitute can alleviate this reliance on cadaveric corneal graft material. Here, isolated primary human corneal endothelial cells (CEnCs) propagated using a dual media approach refined towards regulatory compliance showed expression of markers indicative of the human corneal endothelium, and can be tissue-engineered onto thin corneal stromal carriers. Both cellular function and clinical adaptability was demonstrated in a pre-clinical rabbit model of bullous keratopathy using a tissue-engineered endothelial keratoplasty (TE-EK) approach, adapted from routine endothelial keratoplasty procedure for corneal transplantation in human patients. Cornea thickness of rabbits receiving TE-EK graft gradually reduced over the first two weeks, and completely recovered to a thickness of approximately 400 µm by the third week of transplantation, whereas corneas of control rabbits remained significantly thicker over 1,000 µm (p < 0.05) throughout the course of the study. This study showed convincing evidence of the adaptability of the propagated CEnCs and their functionality via a TE-EK approach, which holds great promises in translating the use of cultured CEnCs into the clinic.
IMPORTANCE Descemet stripping automated endothelial keratoplasty (DSAEK) for isolated endothelial dysfunction has become the preferred surgical option for many corneal surgeons. However, there are limited large-scale reports on DSAEK survival and clinical variables affecting the risk of rejection and failure after failed penetrating keratoplasty (PK). OBJECTIVE To report the survival, risk factors for graft rejection and failure, and visual outcome of DSAEK after failed PK. DESIGN, SETTING, AND PARTICIPANTS A multicenter retrospective interventional case series included patients recruited from 6 tertiary referral surgical centers: 3 in the United States, 2 in Europe, and 1 in Asia. A total of 246 consecutive eyes (246 patients) that underwent DSAEK after failed PK, with a minimum follow-up period of 1 month, was included. Data comprising demographic details, preoperative and postoperative risk factors, time to rejection, time to failure, and corrected distance visual acuity were collected. MAIN OUTCOMES AND MEASURES Cumulative probability of graft survival, hazard ratio estimates for survival, and corrected distance visual acuity were determined. RESULTS The mean (SD) recipient age was 63.2 (16.6) years and the median follow-up period was 17 months (interquartile range, 6-30 months). One-third of the grafts (n = 82) had follow-up data for more than 2 years; 18.3% had more than 1 failed PK before DSAEK. In total, 19.1% (47 of 246) of DSAEK grafts failed. The cumulative probability of DSAEK survival after a failed PK was 0.89 (95% CI, 0.84-0.92), 0.74 (95% CI, 0.64-0.81), and 0.47 (95% CI, 0.29-0.61) at 1 year, 3 years, and 5 years, respectively. Based on multivariate analysis, significant preoperative risk factors for failure were young recipient age (hazard ratio [HR], 5.18 [95% CI, 1.57-17.18]), previous tube filtration surgery (HR, 5.23 [95% CI, 1.47-7.33]), and rejection episodes before PK failure (HR, 3.28 [95% CI, 1.47-7.33]); single-surgeon centers had a protective effect. Any rejection episode prior to PK failure was a significant predictor of post-DSAEK rejection, which in turn was a significant predictor of DSAEK failure. After a median follow-up of 17 months, 33.3% of the grafts achieved 0.3 or greater logMAR (20/40) corrected distance visual acuity. CONCLUSIONS AND RELEVANCE Descemet stripping automated endothelial keratoplasty after failed PK combines greater wound stability and reduced suture-related complications, with visual outcomes and graft survival rates comparable to those of a second PK.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.