Peri-implant infection is a serious complication in surgical procedures involving implants. We conducted an in vitro study to determine whether the use of a fluorinated diamond-like carbon (F-DLC) coating on a titanium alloy surface can prevent peri-implant infection. After applying the F-DLC, we evaluated its antibacterial and cytotoxic properties. The coating groups, containing controlled fluorine concentrations of 5.44%, 17.43%, 24.09%, and 30%, were examined for the presence of Staphylococcus aureus and Escherichia coli according to ISO 22196 for the measurement of antibacterial activity on plastics and other nonporous surfaces. Biological toxicity was evaluated using Chinese hamster V79 cells according to ISO 10993-5 for the biological evaluation of medical devices. In the control group, populations of S. aureus and E. coli substantially increased from 2.4 × 104 to (1.45 ± 1.11) × 106 colony-forming units (CFUs) and from 2.54 × 104 to (4.04 ± 0.44) × 106 CFUs, respectively. However, no bacteria colonies were detected in any F-DLC group with a fluorine concentration of ≥ 17.43%. In the biological toxicity study, an F-DLC coating with a fluorine concentration of 30% showed a colony formation rate of 105.8 ± 24.1%, which did not differ significantly from the colony formation rate of 107.5 ± 31.1% in the nontoxic control group. An F-DLC coating on titanium alloy discs showed excellent in vitro antibacterial activity with no biological toxicity.
Diamond-like carbon (DLC) films, which are amorphous carbon films, have been used as hard-coating films for protecting the surface of mechanical parts. Nitrogen-containing DLC (N-DLC) films are expected as conductive hard-coating materials. N-DLC films are expected in applications such as protective films for contact pins, which are used in the electrical check process of integrated circuit chips. In this study, N-DLC films are prepared using the T-shaped filtered arc deposition (T-FAD) method, and film properties are investigated. Film hardness and film density decreased when the N content increased in the films because the number of graphite structures in the DLC film increased as the N content increased. These trends are similar to the results of a previous study. The electrical resistivity of N-DLC films changed from 0.26 to 8.8 Ω cm with a change in the nanoindentation hardness from 17 to 27 GPa. The N-DLC films fabricated by the T-FAD method showed high mechanical hardness and low electrical resistivity.
A new technique to etch a substrate as a pre-treatment prior to functional film deposition was developed using a filtered vacuum arc plasma. An Ar-dominated plasma beam was generated from filtered carbon arc plasma by introducing appropriate flow rate of Ar gas in a T-shape filtered arc deposition (T-FAD) system. The radiation spectra emitted from the filtered plasma beam in front of a substrate table were measured. The substrate was etched by the Ar-dominated plasma beam. The principal results are summarized as follows. At a high flow rate of Ar gas (50 ml/min), when the bias was applied to the substrate, the plasma was attracted toward the substrate table and the 2 substrate was well etched without film formation on the substrate. Super hard alloy (WC), bearing steel (SUJ2), and Si wafer were etched by the Ar-dominated plasma beam. The etching rate was dependent on the kind of substrate. The roughness of the substrate increased, when the etching rate was high. A pulse bias etched the substrate without roughening the substrate surface excessively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.