BackgroundRhythm outcomes after the pulmonary vein isolation (PVI) using the cryoballoon (CB) are reported to be excellent. However, the lesions after CB ablation have not been well discussed. We sought to characterize and compare the lesion formation after CB ablation with that after radiofrequency (RF) ablation.MethodsA total of 42 consecutive patients who underwent PVI were enrolled (29 in the CB group and 13 in the RF group). The PVI lesions were assessed by late gadolinium enhancement magnetic resonance imaging 1–3 months after the PVI. The region around the PVs was divided into eight segments: roof, anterior‐superior, anterior‐carina, anterior‐inferior, bottom, posterior‐inferior, posterior‐carina, and posterior‐superior segment. The lesion width and lesion gap in each segment were compared between the two groups. Lesion gaps were defined as no‐enhancement sites of >4 mm.ResultsAs compared to the RF group, the overall lesion width was significantly wider and lesion gaps significantly fewer at the anterior‐superior segment of the left PV (LAS) and anterior‐inferior segment of the right PV (RAI) in the CB group (lesion width: 8.2 ± 2.2 mm vs 5.6 ± 2.0 mm, P = .001; lesion gap at LAS: 7% vs 38%, P = .02; lesion gap at RAI: 7% vs 46%, P = .006).ConclusionsThe PVI lesions after CB ablation were characterized by extremely wider and more continuous lesions than those after RF ablation.
Background: Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are characterized as a wider and more continuous than that after conventional radiofrequency catheter ablation (RFCA) without the contact force (CF)-sensing technology. However, the impact on the lesion characteristics of ablation with a CFsensing catheter has not been well discussed. We sought to assess the lesions using late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) and to compare the differences between the two groups (CB group vs. RF group). Methods: A total of 30 consecutive patients who underwent PVI were enrolled (CB group, 18; RF group, 12). The RF applications were delivered with a target lesion size index (LSI) of 5. The PVI lesions were assessed by LGE-MRI 3 months after the PVI. The region around the PV was divided into eight segments: roof, anteriorsuperior, anterior carina, anterior inferior, bottom, posterior inferior, posterior carina, and posterior superior segment. The lesion width and visual gap of each segment were compared between the two groups. The visual gaps were defined as no-enhancement site of >4 mm. Results: The mean LSI was 4.7 ± 0.7. The lesion width was significantly wider but the visual gaps were more frequently documented at the bottom segment of right PV in the CBA group (lesion width: 8.1 ± 2.2 vs. 6.3 ± 2.2 mm; p = .032; visual gap at the bottom segment or right PV: 39% vs. 0%; p = .016). Conclusions: The PVI lesion was wider after CBA, while the visual gaps were fewer after RFCA with a CF-sensing catheter.
Background A computational model demonstrated that atrial fibrillation (AF) rotors could be distributed in patchy late‐gadolinium enhancement (LGE) areas and play an important role in AF drivers. However, this was not validated in humans. Objective The purpose of this study was to evaluate the LGE properties of AF rotors in patients with persistent AF. Methods A total of 287 segments in 15 patients with persistent AF (long‐standing persistent AF in 9 patients) that underwent AF ablation were assessed. Non‐passively activated areas (NPAs), where rotational activation (AF rotor) was frequently observed, were detected by the novel real‐time phase mapping (ExTRa Mapping). The properties of the LGE areas were assessed using the LGE heterogeneity and the density which was evaluated by the entropy (LGE‐entropy) and the volume ratio of the enhancement voxel (LGE‐volume ratio), respectively. Results NPAs were found in 61 (21%) of 287 segments and were mostly found around the pulmonary vein antrum. A receiver operating characteristic curve analysis yielded an optimal cutoff value of 5.7% and 10% for the LGE‐entropy and LGE‐volume ratio, respectively. The incidence of NPAs was significantly higher at segments with an LGE‐entropy of >5.7 and LGE‐volume ratio of >10% than at the other segments (38 [30%] of 126 vs. 23 [14%] of 161 segments; p = .001). No NPAs were found at segments with an LGE‐volume ratio of >50% regardless of the LGE‐entropy. Of five patients with AF recurrence, NPAs outside the PV antrum were not ablated in three patients and the remaining NPAs were ablated, but their LGE‐entropy and LGE‐volume ratio were low. Conclusion AF rotors are mostly distributed in relatively weak and much more heterogenous LGE areas.
Introduction Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are wide and continuous, however, the distribution can depend on the pulmonary vein (PV) size. We sought to assess the relationship between the lesion distribution and PV size after CBA and hotballoon ablation (HBA). Methods and Results A total of 80 consecutive patients who underwent PVI were enrolled (40 with CBA). The lesions were visualized by late‐gadolinium enhancement magnetic resonance imaging. The lesion width, lesion gaps, and distance from the PV ostium (PVos) to distal lesion edge (DLE) were assessed. If the DLE extended inside the PV, the value was expressed as a negative value. Although the lesion width was significantly wider in the CB group (7.8 ± 2.0 vs 4.9 ± 1.0 mm, P < .001), the number of lesion gaps was significantly less in the HB group (2.9 ± 2.4 vs 1.3 ± 1.4 gaps, P = .001). The distance from the PVos to DLE was a negative value in both groups, but the impact was significantly greater (−1.5 ± 1.8 vs −0.2 ± 1.2 mm, P < .001) and negatively correlated with PV size in the CB group, but not in HB group (r = −0.27, P = .007). The AF recurrence 12 months after the procedure did not differ (5 [12.5%] of 40 in the CB group vs 4 [10%] of 40 in the HB group, P = .695). Conclusions The PVI lesions after HBA were characterized by (a) narrower, but (b) more continuous, (c) smaller lesion inside the PV, and (d) irrespective of PV size as compared to that after CBA.
Introduction:The ablation index (AI) and lesion size index (LSI) are novel markers for predicting the ablation lesion quality, however, collateral damage is still a concern.This study aimed to compare the lesion characteristics and tissue temperature profiles between 20 W (20 Ws) and 40 W (40 Ws) ablation settings under the same AI and LSI.Methods: An ex vivo model consisting of swine myocardium (5-6 mm thickness) in a circulating, warmed saline bath was used. Twenty-one tissue temperature electrodes were used. Radiofrequency applications with different power settings were performed with a 10 to 12 g contact force until the AI and LSI reached 350 and 4.5, respectively.Results: A total of 120 radiofrequency (RF) applications and 2520 tissue temperature profiles were analyzed. The speed of the tissue temperature rise with 40 Ws was significantly faster than that with 20 Ws. However, the maximum tissue temperature did not significantly differ between 20 and 40 Ws with the same AI (44.6°C ± 3.9°C vs 45.1°C ± 6.4°C, P = .73), and was significantly lower for 40 Ws with the same LSI (42.8°C ± 3.4°C vs 40.0°C ± 3.4°C, P = .003). For both the AI and LSI, the number of electrodes exhibiting high temperatures (≥39°C) was significantly larger and the duration of high tissue temperatures was significantly longer with 20 Ws. The thermal latency with 40 Ws was greater.Conclusions: Although the targeted AI and LSI were the same for both 20 and 40 Ws, the tissue temperature profiles differed greatly depending on the RF power setting. A high power setting based on the AI and LSI may reduce the collateral thermal damage. K E Y W O R D S ablation index, catheter ablation, lesion size index, tissue thermodynamics 1 | INTRODUCTION Pulmonary vein isolation (PVI) is a cornerstone of radiofrequency (RF) catheter ablation of atrial fibrillation. Transmural and continuous ablation lesions are essential factors for preventing reconduction of the PVs, however, an excessive contact force and overheating of the tissue can cause steam pops, cardiac perforations, and collateral damage. Low power long duration RF settings (20-25 W × 20-30 seconds) have been used for the posterior wall of the left atrium (LA) especially in areas adjacent to the esophagus.
Background Medium‐dose (25 gray) x‐ray radiation therapy has recently been performed on patients with refractory ventricular tachyarrhythmias. Unlike x‐ray, carbon ion and proton beam radiation can deliver most of their energy to the target tissues. This study investigated the electrophysiological and pathological changes caused by medium‐dose carbon ion and proton beam radiation in the left ventricle (LV). Methods and Results External beam radiation in the whole LV was performed in 32 rabbits. A total of 9 rabbits were not irradiated (control). At the 3‐month or 6‐month follow‐up, the animals underwent an open‐chest electrophysiological study and were euthanized for histological analyses. No acute death occurred. Significant LV dysfunction was not seen. The surface ECG revealed a significant reduction in the P and QRS wave voltages in the radiation groups. The electrophysiological study showed that the local conduction times in each LV site were significantly longer and that the local LV bipolar voltages were significantly lower in the radiation groups than in the control rabbits. Histologically, apoptosis, fibrotic changes, and a decrease in the expression of the connexin 43 protein were seen in the LV myocardium. These changes were obvious at 3 months, and the effects were sustained 6 months after radiation. No histological changes were seen in the coronary artery and esophagus, but partial radiation pneumonitis was observed. Conclusions Medium‐dose carbon ion and proton beam radiation in the whole LV resulted in a significant electrophysiological disturbance and pathological changes in the myocardium. Radiation of the arrhythmogenic substrate would modify the electrical status and potentially induce the antiarrhythmic effect.
A 41‐year‐old man with persistent atrial fibrillation (AF) underwent radiofrequency (RF) catheter ablation using an online real‐time phase mapping system: ExTRa Mapping. Box isolation could not terminate AF. Subsequently, RF applications on nonpassively activated areas (NPAs), where rotational activations were frequently observed, at the posterior bottom of left atrium outside of box lesion could convert AF to common atrial flutter. Of interest, the NPA near the posterior bottom were located on the patchy fibrotic tissue area assessed by the late‐gadolinium enhancement magnetic resonance imaging. This indicated the possibility of the critical AF rotor meandering through the fibrotic tissue area.
Background A computer simulation model has demonstrated that atrial fibrillation (AF) driver can be attached to heterogeneous fibrosis assessed by late gadolinium enhancement magnetic resonance imaging (LGE‐MRI). However, it has not been well elucidated in patients with persistent AF. The aim of this study was to investigate whether radiofrequency (RF) applications in the fragmented LGE area (FLA) could terminate AF or convert it to atrial tachycardia (AT) and improve the rhythm outcome. Methods A total of 31 consecutive persistent AF patients with FLAs were enrolled (FLA ablation group, mean age: 69 ± 8 years, mean left atrial diameter: 42 ± 6 mm). A favorable response was defined as direct AF termination or AT conversion during RF applications at the FLA. The rhythm outcome was compared between the FLA ablation group and FLA burden‐matched pulmonary vein isolation (PVI) group. Results Favorable responses were found in 15 (48%) of 31 patients in the FLA group (AF termination in seven, AT conversion in eight patients), but not in the PVI group. AF recurrence at 12 months follow‐up was significantly less in the FLA ablation group than in the PVI group (4 [13%] vs. 12 [39%] of 31 patients, log‐rank p = .023). In patients with a favorable response, AT recurred in 1 (7%) of 15 patients, but AF did not. Conclusions FLA ablation could terminate AF or convert it to AT in half of the patients. No AF recurrence was documented in patients with a favorable response.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.