MS patients have subclinical LV and RV systolic dysfunction by GLS despite normal ejection fraction and fractional area change. BMV results in marked improvement in LV and RV GLS immediately post-BMV with trend towards normalization at follow-up after 3 months. A mixed aetiology theory involving a myocardial as well as a haemodynamic factor is believed to be the cause for this subclinical biventricular dysfunction and its improvement at short-term follow-up post-BMV.
Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. Data were collected, and different correlations were applied to determine factors that influence variability of X-ray exposure. The fluoroscopy time (FT) differed significantly between the diagnostic (8.9 ± 6.3 min) and intervention (12.8 ± 9.98 min) groups (P = 0.032). The mean dose-area product (DAP) differed significantly between the two groups (3.775 ± 2.5 Gy/cm(2) vs. 13.239 ± 15.4 Gy/cm(2); P = 0.003). The highest DAP was during left anterior oblique (LAO) cranial 30° angulation (2.8 Gy/cm(2)/4 s cine). The mean cumulative dose (CD) was 0.053 Gy in diagnostic cases and 0.48 Gy in intervention cases. The effective dose was 5.97 ± 7.05 mSv for therapeutic procedures compared with 3.42 ± 3.64 mSv for diagnostic procedures. The FT correlated significantly with both the DAP (r = 0.718; P < 0.001) and the CD (r = 0.701; P < 0.001). Other correlations were reported. An increasing number of therapeutic catheterization procedures are being performed for children. The justification for these procedures is evident because they avoid complicated surgery. However, the complexity of these procedures results in higher radiation exposures.
RT3DE can quantify LVMD by providing the SDI-16 and it may prove to be more useful than DTI as it shows increasing dyssynchrony with increased QRS duration and decreased LVEF.
Background
Ventricular septal defect (VSD) is the most common congenital heart disease. In patients with large VSD, left side chambers are subjected to volume overload with subsequent chambers dilatation and eccentric left ventricular hypertrophy. Percutaneous closure of VSD has been shown to be an effective method with equal safety and efficacy when compared to surgery. The effect of VSD closure on LV remodeling has been mainly assessed in patients treated with surgery and to date published data remain scarce. Therefore, we aim to evaluate the effect of percutaneous VSD closure on different LV parameters.
Results
Seventeen patients (median age 6 years (IQR 4.75–8 years), 70.6% females) who underwent percutaneous VSD closure were enrolled in the study. Sixteen patients (94%) had perimembranous VSD, and one patient had muscular VSD. The procedure was successful in all patients with no major complications. Nit Occlud® Lê coil device was implanted in 16 patients (94%), and one patient received Amplatzer PDA duct occlude device. At 6-months follow-up, there was a significant reduction in indexed LV dimensions [LVEDD/BSA (median 46.5 mm/m2 vs. 42.9 mm/m2, p = 0.03), LVESD/BSA (median 31.7 mm/m2 vs. 26.7 mm/m2, p = 0.02)], indexed LV volumes [LVEDV/BSA (median 52.6 ml/m2 vs. 37.3 ml/m2, p = 0.02), LVESV/BSA (median 31.7 ml/m2 vs. 23.3 ml/m2, p = 0.02)] and indexed LV mass (median 62.4 gm/m2 vs. 57.9 ml/m2, p = 0.01). There was a significant reduction in LVEDD Z-score (p = 0.01) and LVESD Z-score (p = 0.04). There was no significant change in LV EF.
Conclusions
Percutaneous VSD closure is associated with improvement of various LV parameters with consequential favorable LV remodeling and function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.