As cochlear implants have become increasingly successful in the rehabilitation of adults with profound hearing impairment, the number of pediatric implant subjects has increased. We have developed an animal model of congenital deafness and investigated the effect of electrical stimulus frequency on the temporal resolution of central neurons in the developing auditory system of deaf cats. Maximum following frequencies (Fmax) and response latencies of isolated single neurons to intracochlear electrical pulse trains (charge balanced, constant current biphasic pulses) were recorded in the contralateral inferior colliculus (IC) of two groups of neonatally deafened, barbiturate-anesthetized cats: animals chronically stimulated with low-frequency signals (< or = 80 Hz) and animals receiving chronic high-frequency stimulation (> or = 300 pps). The results were compared with data from unstimulated, acutely deafened and implanted adult cats with previously normal hearing (controls). Characteristic differences were seen between the temporal response properties of neurons in the external nucleus (ICX; approximately 16% of the recordings) and neurons in the central nucleus (ICC; approximately 81% of all recordings) of the IC: 1) in all three experimental groups, neurons in the ICX had significantly lower Fmax and longer response latencies than those in the ICC. 2) Chronic electrical stimulation in neonatally deafened cats altered the temporal resolution of neurons exclusively in the ICC but not in the ICX. The magnitude of this effect was dependent on the frequency of the chronic stimulation. Specifically, low-frequency signals (30 pps, 80 pps) maintained the temporal resolution of ICC neurons, whereas higher-frequency stimuli significantly improved temporal resolution of ICC neurons (i.e., higher Fmax and shorter response latencies) compared with neurons in control cats. Furthermore, Fmax and latencies to electrical stimuli were not correlated with the tonotopic gradient of the ICC, and changes in temporal resolution following chronic electrical stimulation occurred uniformly throughout the entire ICC. In all three experimental groups, increasing Fmax was correlated with shorter response latencies. The results indicate that the temporal features of the chronically applied electrical signals critically influence temporal processing of neurons in the cochleotopically organized ICC. We suggest that such plastic changes in temporal processing of central auditory neurons may contribute to the intersubject variability and gradual improvements in speech recognition performance observed in clinical studies of deaf children using cochlear implants.
In an animal model of prelingual deafness, we examined the anatomical and physiological effects of prolonged deafness and chronic electrical stimulation on temporal resolution in the adult central auditory system. Maximum following frequencies (F max ) and first spike latencies of single neurons responding to electrical pulse trains were evaluated in the inferior colliculus of two groups of neonatally deafened cats after prolonged periods of deafness (Ͼ2.5 yr): the first group was implanted with an intracochlear electrode and studied acutely (long-deafened unstimulated, LDU); the second group (LDS) received a chronic implant and several weeks of electrical stimulation (pulse rates Ն300 pps). Acutely deafened and implanted adult cats served as controls. Spiral ganglion cell density in all long-deafened animals was markedly reduced (mean Ͻ5.8% of normal). Both long-term deafness and chronic electrical stimulation altered temporal resolution of neurons in the central nucleus (ICC) but not in the external nucleus. Specifically, LDU animals exhibited significantly poorer temporal resolution of ICC neurons (lower F max , longer response latencies) as compared with control animals. In contrast, chronic stimulation in LDS animals led to a significant increase in temporal resolution. Changes in temporal resolution after long-term deafness and chronic stimulation occurred broadly across the entire ICC and were not correlated with its tonotopic gradient. These results indicate that chronic electrical stimulation can reverse the degradation in temporal resolution in the auditory midbrain after long-term deafness and suggest the importance of factors other than peripheral pathology on plastic changes in the temporal processing capabilities of the central auditory system.
Current cochlear prostheses use amplitude-modulated pulse trains to encode acoustic signals. In this study we examined the responses of inferior colliculus (IC) neurons to sinusoidal amplitude-modulated pulses and compared the maximum unmodulated pulse rate (Fmax) to which they responded with the maximum modulation frequency (maxFm) that they followed. Consistent with previous results, responses to unmodulated pulses were all low-pass functions of pulse rate. Mean Fmax to unmodulated pulses was 104 pulses per second (pps) and modal Fmax was 60 pps. Above Fmax IC neurons ceased responding except for an onset burst at the beginning of the stimulus. However, IC neurons responded to much higher pulse rates when these pulses were amplitude modulated; 74% were relatively insensitive to carrier rate and responded to all modulated carriers including those exceeding 600 pps. In contrast, the responses of these neurons (70%) were low-pass functions of modulation frequency, and the remaining (30%) had band-pass functions with a maxFm of 42 and 34 Hz, respectively. Thus temporal resolution of IC neurons for modulated frequencies is significantly lower than that for unmodulated pulses. These two measures of temporal resolution (Fmax and maxFm) were uncorrelated (r(2) = 0.101). Several parameters influenced the amplitude and temporal structure of modulation responses including modulation depth, overall intensity and modulation-to-carrier rate ratio. We observed distortions in unit responses to amplitude-modulated signals when this ratio was 1/4 to 1/6. Since most current cochlear implant speech processors permit ratios that are significantly greater than this, severe distortion and signal degradation may occur frequently in these devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.