Machine learning (ML) has been increasingly used within cardiology, particularly in the domain of cardiovascular imaging. Due to the inherent complexity and flexibility of ML algorithms, inconsistencies in the model performance and interpretation may occur. Several review articles have been recently published that introduce the fundamental principles and clinical application of ML for general cardiologists. The current document builds on these introductory principles and outlines a more comprehensive list of crucial responsibilities that need to be completed when developing ML models. The document thus aims to serve as a scientific foundation to aid investigators, data scientists, authors, editors, and reviewers involved in machine learning research with the intent of uniform reporting of ML investigations. An independent multidisciplinary panel of ML experts, clinicians, and statisticians worked together to review the theoretical rationale underlying seven sets of requirements that may reduce algorithmic errors and biases. Finally, the document summarizes a list of reporting items as an itemized checklist that highlight steps for ensuring correct application of ML models and the consistent reporting of model specifications and results. It is expected that the rapid pace of research and development and the increased availability of real-world evidence may require periodic updates to the checklist.
Machine learning of spatiotemporal variations of LV strain rate during rest and exercise could be used to identify patients with HFpEF and to provide an objective basis for diagnostic classification.
Statistical shape modeling is a powerful tool for visualizing and quantifying geometric and functional patterns of the heart. After myocardial infarction (MI), the left ventricle typically remodels in response to physiological challenges. Several methods have been proposed in the literature to describe statistical shape changes. Which method best characterizes left ventricular remodeling after MI is an open research question. A better descriptor of remodeling is expected to provide a more accurate evaluation of disease status in MI patients. We therefore designed a challenge to test shape characterization in MI given a set of three-dimensional left ventricular surface points. The training set comprised 100 MI patients, and 100 asymptomatic volunteers (AV). The challenge was initiated in 2015 at the Statistical Atlases and Computational Models of the Heart workshop, in conjunction with the MICCAI conference. The training set with labels was provided to participants, who were asked to submit the likelihood of MI from a different (validation) set of 200 cases (100 AV and 100 MI). Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve were used as the outcome measures. The goals of this challenge were to (1) establish a common dataset for evaluating statistical shape modeling algorithms in MI, and (2) test whether statistical shape modeling provides additional information characterizing MI patients over standard clinical measures. Eleven groups with a wide variety of classification and feature extraction approaches participated in this challenge. All methods achieved excellent classification results with accuracy ranges from 0.83 to 0.98. The areas under the receiver operating characteristic curves were all above 0.90. Four methods showed significantly higher performance than standard clinical measures. The dataset and software for evaluation are available from the Cardiac Atlas Project website1.
The aim of this study was to analyze the whole temporal profiles of the segmental deformation curves of the left ventricle (LV) and describe their interrelations to obtain more detailed information concerning global LV function in order to be able to identify abnormal changes in LV mechanics. The temporal characteristics of the segmental LV deformation curves were compactly described using an efficient decomposition into major patterns of variation through a statistical method, called Principal Component Analysis (PCA). In order to describe the spatial relations between the segmental traces, the PCA-derived temporal features of all LV segments were concatenated. The obtained set of features was then used to build an automatic classification system. The proposed methodology was applied to a group of 60 MRI-delayed enhancement confirmed infarct patients and 60 controls in order to detect myocardial infarction. An average classification accuracy of 87% with corresponding sensitivity and specificity rates of 89% and 85%, respectively was obtained by the proposed methodology applied on the strain rate curves. This classification performance was better than that obtained with the same methodology applied on the strain curves, reading of two expert cardiologists as well as comparative classification systems using only the spatial distribution of the end-systolic strain and peak-systolic strain rate values. This study shows the potential of machine learning in the field of cardiac deformation imaging where an efficient representation of the spatio-temporal characteristics of the segmental deformation curves allowed automatic classification of infarcted from control hearts with high accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.