This paper reports the effect of different adiabatic lengths on the thermal performance of loop thermosyphon with different filling ratios (FRs) and heat inputs. The carbon steel thermosyphon loop for three different adiabatic lengths is used in this analysis. The loop with plate-type, forced air-cooled condenser, along with two vertical inline evaporators, is filled and tested with distilled water. The transient and steady-state analyses are carried out to understand the thermal behavior of the loop. The thermal resistance is found to be lowest at 800-mm adiabatic length and 60% FR. The geyser boiling phenomenon is also noticed in the present thermosyphon loop. The period of oscillation and temperature fluctuations in the evaporator and condenser increase with the adiabatic length. The geyser boiling phenomenon may disappear at a very small adiabatic length of the loop thermosyphon with forced air-cooled condenser. This paper proposes a mathematical model for the loop thermosyphon in terms of the Nusselt number, the Reynolds number, the Prandtl number, and the adiabatic length-todiameter ratio, and the comparative study shows that proposed model validates the experimental results. Also, it is found that the adiabatic length-to-diameter ratio inversely varies with the Nusselt number.
The thermal management of the compact electronic system is one of the major challenges in the present power electronics and computational industries. The present paper investigates the effects of a pump-driven flow on the thermal performance of a closed-loop thermosyphon (CLT) system. This paper discusses the effect of pump-driven flow on the thermal performance of CLT. In this study, the experimentation is carried out on the water-charged pump-driven closed-loop thermosyphon (PDLT) with different heat inputs, filling ratios (FR), and adiabatic lengths to understand the effects of these parameters on the thermal performance of the system. The results indicate that the heat transfer performance of CLT is improved using pump-driven flow in the PDLT and the minimum thermal resistance (0.035 k/W) is obtained at FR = 0.6 and 3 kW heat input. It is also noticed that the thermal resistance of PDLT is up to 35% higher than CLT at FR = 0.6, 0.5 kW heat input, and 500 mm adiabatic length. The unstable geyser boiling phenomenon is eliminated from the system at the adiabatic lengths of 200 and 500 mm. However, for long adiabatic length (800 mm), the geyser boiling occurs at a higher FR (FR = 0.6) and moderate heat flux (0.5 kW).
This paper reports an experimental investigation of a closed‐loop thermosyphon system charged with water and other low saturation fluids, such as ethanol, acetone, and methanol, for different adiabatic lengths, filling ratios, and heat loads. The closed‐loop thermosyphon with two inline vertical heaters in the evaporator section and forced air‐cooled plate‐type heat exchanger in the condenser section, connected by a changeable adiabatic length, is investigated at different working conditions. Out of five filling ratios used in the analysis, at 0.6 filling ratio, the loop thermosyphon is seen to be operated at its best. The acetone‐charged loop thermosyphon shows the lowest values (up to 72% reduction) of overall thermal resistance than that of other fluids and significantly higher effectiveness, due to the plate‐type forced air‐cooled condenser. For the acetone‐filled thermosyphon, an almost 15% increase in the effectiveness is observed by changing the adiabatic length from 800 to 200 mm. This study suggests that the limitation of the loop thermosyphon with a water‐cooled condenser to cool electronic components, computational clusters, and data centers is well fulfilled by the loop thermosyphon with plate‐type forced air‐cooled condenser. The nucleate pool boiling correlation is developed and validated for the loop thermosyphon system to determine the evaporator heat transfer coefficient.
Wind is a one of the clean resources of energy and has the ability to contribute a considerable share in growing world energy consumption. The small wind turbine plays a vital role in fulfillment of energy needs preferably for household purpose. In order to unleash the budding of applicability of small wind turbine, it is necessary to improve its performance. The performance of a small wind turbine can be distinguished by the manners in which power, thrust and torque vary with the wind speed. The wind power indicates the amount of energy captured by the wind turbine rotor. It is convenient to express the performance of small wind turbine by means of non-dimensional performance curves, therefore in this paper the most graphs are drawn to power, thrust and torque coefficients as a function of the tip speed ratio. This paper presents the effect of design parameters such as the tip speed ratio, angle of attack, wind speed, solidity, number of blades, etc. on the aerodynamic performance of small wind turbine and proposes the optimum values of these parameters for the newly designed blade. The new designed blade consists of two new airfoils and named as IND 15045 and IND 09848. This new profile blade is designed for a wind turbine of 1 kW rated power. The blade is divided into ten sections. The designed length of blade is 1.5 m and it is made using IND 15045 airfoils at three root sections and IND 09848 airfoils for remaining seven sections. Q-Blade is used for the numerical simulation of wind turbine airfoils and blade. It is integrated tool of XFOIL and blade element momentum theory of wind turbine blade design. Also the effect of constant rotational speed operation, effect of stall regulation effect of rotational speed change and the effect of solidity on the performance of wind turbine is discussed. This paper delivers a broad view of perception for design of small wind turbine and parameter selection for the new wind turbine blade. Also in this paper the effect of different losses viz. tip losses, drag losses, stall losses and hub losses on the small wind turbine are discussed. The efficiency of the small wind turbine varies significantly with wind speed, but it would be designed such a way that maximized efficiencies are achieved at the wind speed where the maximum energy is available.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.