Upper calyx endoscopic approachability through the lower calyx is significantly higher in supine than in prone percutaneous nephrolithotomies, possibly due to a thinner body wall, a thinner muscular layer, a lower muscle-to-fat thickness ratio and a wider angle between the lower and upper calyx axes.
Background: Obstructive nephropathy is an uncommon side effect of sulfadiazine, which is used for the treatment of toxoplasmosis. We present a case of acute renal colic and urine extravasation of a patient shortly after she was started on this medication.Case Presentation: A 31-year-old female presented with acute renal colic 2 weeks after starting treatment with sulfadiazine and pyrimethamine for ocular toxoplasmosis.Results: A noncontrast computed tomography revealed left hydronephrosis and fluid located around the kidney and in the left gutter. There were no urinary stones. Administration of intravenous contrast revealed significant urine extravasation at the level of the ureteropelvic junction. Intravenous contrast injection confirmed that the extravasation consisted of urine leakage at the ureteropelvic junction. Her clinical condition improved with the insertion of an internal stent, which was left in place for 4 weeks. A retrograde pyelography performed at the time of the internal stent removal ruled out persistent extravasation and filling defects in the left upper urinary tract. Considering the clinical circumstances and the imaging results, it appears that this is a first reported case of sulfadiazine-induced obstructive uropathy associated with urine extravasation.Conclusion: Although rare, obstructive uropathy related to sulfadiazine medication should be promptly suspected, diagnosed, and treated. Patients should be instructed to substantially increase their liquid intake while on that medication.
<b><i>Introduction:</i></b> The Butterfly Prostatic Retraction device is a novel transurethral implant designed to dilate the prostatic urethra and treat lower urinary tract symptoms. We assessed its safety, efficacy and impact on urinary flow, ejaculation, and quality of life. <b><i>Materials and Methods:</i></b> We included 64 men, treated for benign prostate hyperplasia for at least 1 year. All patients had Qmax≤ 13 mL/s and IPSS >12. Insertion of the device was performed via cystoscopy. Follow-up visits were performed at 2 weeks, 1, 3, 6, and 12 months and included uroflowmetry, IPSS, QoL, and sexual function questionnaires. Cystoscopy was performed on 3 and 12 months. <b><i>Results:</i></b> Patients age was 50–83 years. 28 patients completed a 1-year follow-up with an intact device. Mean Qmax improved by 2 mL/s (25%), IPSS median drop was 10 points (40%), and QoL score was 1.5 points (38%). Sexually active patients reported antegrade ejaculation. On cystoscopy, gradual coverage of the devices with urethral mucosa was observed. In 1 patient, the device was repositioned. In 19 patients, the device was removed. 12 patients returned to alpha-blocker therapy and 7 patients underwent TURP. One patient developed a bulbar urethral stricture. <b><i>Conclusions:</i></b> We demonstrated feasibility and good tolerability of the Butterfly device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.