Appropriate patient selection and minimizing complications are critical for successful spinal cord stimulation (SCS) therapy in managing intractable pain. We thus reviewed electronic medical records of 707 consecutive cases of patients who received SCS therapy in the Cleveland Clinic from 2000 to 2005 with an emphasis on indications and complications. SCS was used to treat complex regional pain syndrome (CRPS) (345 cases), failed back surgery syndrome (235 cases), peripheral vascular disease (20 cases), visceral pain in the chest, abdomen, and pelvis (37 cases), and peripheral neuropathy (70 cases). CRPS and failed back surgery syndrome accounted for 82% of the cases. The implant-totrial ratio was 75% on average, with the highest for CRPS type 2 (83%) and the lowest for peripheral vascular diseases (65%). The only documented complication associated with SCS trials was lead migration in 5 of 707 patients (0.7%). There were no permanent neurological deficits or deaths as a result of SCS implant or its complications. Hardware-related complications were common (38%) and included lead migration (22.6%), lead connection failure (9.5%), and lead breakage (6%). Revisions or replacements were required in these cases. Biologically related complications included pain at the generator site (12%) and clinical infection (4.5%; 2.5% with positive culture). The rates of infection varied among the different diagnoses with the highest in failed back surgery syndrome (6.3%). Patients with diabetes had an infection rate of 9%, over the 4% in non-diabetics. Infections were managed successfully with explantation and antibiotic therapy without permanent sequela.
IMPORTANCE Many patients with diabetic peripheral neuropathy experience chronic pain and inadequate relief despite best available medical treatments.OBJECTIVE To determine whether 10-kHz spinal cord stimulation (SCS) improves outcomes for patients with refractory painful diabetic neuropathy (PDN). DESIGN, SETTING, AND PARTICIPANTSThe prospective, multicenter, open-label SENZA-PDN randomized clinical trial compared conventional medical management (CMM) with 10-kHz SCS plus CMM. Participants with PDN for 1 year or more refractory to gabapentinoids and at least 1 other analgesic class, lower limb pain intensity of 5 cm or more on a 10-cm visual analogue scale (VAS), body mass index (calculated as weight in kilograms divided by height in meters squared) of 45 or less, hemoglobin A 1c (HbA 1c ) of 10% or less, daily morphine equivalents of 120 mg or less, and medically appropriate for the procedure were recruited from clinic patient populations and digital advertising. Participants were enrolled from multiple sites across the US, including academic centers and community pain clinics, between August 2017 and August 2019 with 6-month follow-up and optional crossover at 6 months. Screening 430 patients resulted in 214 who were excluded or declined participation and 216 who were randomized. At 6-month follow-up, 187 patients were evaluated.INTERVENTIONS Implanted medical device delivering 10-kHz SCS. MAIN OUTCOMES AND MEASURESThe prespecified primary end point was percentage of participants with 50% pain relief or more on VAS without worsening of baseline neurological deficits at 3 months. Secondary end points were tested hierarchically, as prespecified in the analysis plan. Measures included pain VAS, neurological examination, health-related quality of life (EuroQol Five-Dimension questionnaire), and HbA 1c over 6 months. RESULTSOf 216 randomized patients, 136 (63.0%) were male, and the mean (SD) age was 60.8 (10.7) years. Additionally, the median (interquartile range) duration of diabetes and peripheral neuropathy were 10.9 (6.3-16.4) years and 5.6 (3.0-10.1) years, respectively. The primary end point assessed in the intention-to-treat population was met by 5 of 94 patients in the CMM group (5%) and 75 of 95 patients in the 10-kHz SCS plus CMM group (79%; difference, 73.6%; 95% CI, 64.2-83.0; P < .001). Infections requiring device explant occurred in 2 patients in the 10-kHz SCS plus CMM group (2%). For the CMM group, the mean pain VAS score was 7.0 cm (95% CI, 6.7-7.3) at baseline and 6.9 cm (95% CI, 6.5-7.3) at 6 months. For the 10-kHz SCS plus CMM group, the mean pain VAS score was 7.6 cm (95% CI, 7.3-7.9) at baseline and 1.7 cm (95% CI, 1.3-2.1) at 6 months. Investigators observed neurological examination improvements for 3 of 92 patients in the CMM group (3%) and 52 of 84 in the 10-kHz SCS plus CMM group (62%) at 6 months (difference, 58.6%; 95% CI, 47.6-69.6; P < .001).CONCLUSIONS AND RELEVANCE Substantial pain relief and improved health-related quality of life sustained over 6 months demonstrates 10-kHz SCS can s...
Background: Safe and effective non-surgical treatments are an important part of the knee osteoarthritis (OA) treatment algorithm. Cooled radiofrequency ablation (CRFA) and hyaluronic acid (HA) injections are two commonly used modalities to manage symptoms associated with knee OA. Methods: A prospective 1:1 randomized study was conducted in 177 patients comparing CRFA to HA injection with follow-ups at 1, 3, 6 and 12 months. HA subjects with unsatisfactory outcomes at 6-months were allowed to crossover and receive CRFA. Knee pain (numeric rating scale = NRS), WOMAC Index (pain, stiffness and physical function), overall quality of life (global perceived effect = GPE, EQ-5D-5 L), and adverse events were measured. Results: At 12-months, 65.2% of subjects in the CRFA cohort reported ≥50% pain relief from baseline. Mean NRS pain score was 2.8 ± 2.4 at 12 months (baseline 6.9 ± 0.8). Subjects in the CRFA cohort saw a 46.2% improvement in total WOMAC score at the 12-month timepoint. 64.5% of subjects in the crossover cohort reported ≥50% pain relief from baseline, with a mean NRS pain score of 3.0 ± 2.4 at 12 months (baseline 7.0 ± 1.0). After receiving CRFA, subjects in the crossover cohort had a 27.5% improvement in total WOMAC score. All subjects receiving CRFA reported significant improvement in quality of life. There were no serious adverse events related to either procedure and overall adverse event profiles were similar.
Background: Knee osteoarthritis is a painful and sometimes debilitating disease that often affects patients for years. Current treatments include short-lasting and often repetitive nonsurgical options, followed by surgical intervention for appropriate candidates. Cooled radiofrequency ablation (CRFA) is a minimally invasive procedure for the treatment of pain related to knee osteoarthritis. This trial compared the efficacy and safety of CRFA with those of a single hyaluronic acid (HA) injection. Methods: Two hundred and sixty subjects with knee osteoarthritis pain that was inadequately responsive to prior nonoperative modalities were screened for enrollment in this multicenter, randomized trial. One hundred and eighty-two subjects who met the inclusion criteria underwent diagnostic block injections and those with a minimum of 50% pain relief were randomized to receive either CRFA on 4 genicular nerves or a single HA injection. One hundred and seventy-five subjects were treated (88 with CRFA and 87 with HA). Evaluations for pain (Numeric Rating Scale [NRS]), function (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]), quality of life (Global Perceived Effect [GPE] score and EuroQol-5 Dimensions-5 Level [EQ-5D-5L] questionnaire), and safety were performed at 1, 3, and 6 months after treatment. Results: Demographic characteristics did not differ significantly between the 2 study groups. A total of 158 subjects (76 in the CRFA group and 82 in the HA group) completed the 6-month post-treatment follow-up. In the CRFA group, 71% of the subjects had ≥50% reduction in the NRS pain score (primary end point) compared with 38% in the HA group (p < 0.0001). At 6 months, the mean NRS score reduction was 4.1 ± 2.2 for the CRFA group compared with 2.5 ± 2.5 for the HA group (p < 0.0001). The mean WOMAC score improvement at 6 months from baseline was 48.2% in the CRFA group and 22.6% in the HA group (p < 0.0001). At 6 months, 72% of the subjects in the CRFA group reported improvement in the GPE score compared with 40% in the HA group (p < 0.0001). Conclusions: CRFA-treated subjects demonstrated a significant improvement in pain relief and overall function compared with subjects treated with a single injection of HA. No serious adverse events related to either procedure were noted, and the overall adverse-event profiles were similar. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Purpose Continuous transversus abdominis plane (TAP) block using a catheter has proven its usefulness in reducing opioid requirements and pain scores after lower abdominal surgery. However, there are no reports of its successful use after renal transplant. We tested the hypothesis that continuous TAP block would retrospectively reduce opioid requirement, nausea score and hospital stay after renal transplant surgery. Methods In a retrospective study, we reviewed the data from 63 adult renal transplant recipients—31 with patient-controlled TAP analgesia with standing orders for intravenous as well as oral opioids as needed and 32 with intravenous patient-controlled analgesia. The TAP catheter was inserted preoperatively using an ultra-sound-guided technique. Infusion of ropivacaine 0.2 % at 8 ml basal, 12 ml bolus and a lockout interval of 60 min were maintained for 48 h postoperatively. The primary outcome was total morphine-equivalent dose during the 48-h postoperative period. Secondary outcomes were pain and nausea scores for the 48-h postoperative period. Results The mean 48-h postoperative morphine-equivalent doses [95 % confidence interval] for patient-controlled intravenous analgesia and TAP catheter were 197 [111, 349] and 50 [28, 90], respectively, which were significantly different (P = 0.002). The mean 48-h average verbal response pain scores were 2.94 [2.39, 3.50] and 2.49 [1.93, 3.06], respectively, which were not significantly different (P = 0.26). The mean nausea scores were 0.66 [0.46, 0.87] and 0.60 [0.40, 0.81], respectively, which were not significantly different (P = 0.69). There was no difference regarding hospital stay. Conclusion The use of continuous TAP analgesia for postoperative analgesia after renal transplant was effective in reducing the morphine-equivalent requirements.
Background: Chronic postsurgical pain (CPSP) can be caused by peripheral nerve injury (PNI) resulting from surgical procedures and has a significant neuropathic component. This prospective, single-arm study was conducted to document the effectiveness of 10-kHz spinal cord stimulation (10-kHz SCS) as a treatment for patients with CPSP. Methods: Subjects with CPSP who were refractory to conventional medical interventions and reported pain scores of ≥5 cm on a 10-cm VAS underwent trial stimulations lasting up to 14 days. Epidural leads were implanted at locations appropriate for the primary area of pain, and trials resulting in ≥40% pain relief were considered successful. Subjects with successful trials underwent implantation with a permanent 10-kHz SCS system and were followed for 12 months after implantation. Results: Of the 34 subjects who underwent trial stimulation, 1 was withdrawn early and 29 (87.9%) had a successful trial and received a permanent implant. After 12 months of treatment, the mean VAS score decreased by 6.5 cm, the response rate was 88.0% (22/25), and 18 subjects (62.1%) were remitters with VAS scores sustained at ≤3.0 cm. Scores for all components of the short-form McGill Pain Questionnaire 2 were significantly reduced, including affective descriptors of pain. Pain catastrophizing and vigilance, patient function, physical and mental well-being, and sleep quality all improved over the course of the study. No neurologic deficits reported in the study. Conclusions: 10-kHz SCS is effective and tolerated in patients with CPSP, and further study of its clinical application in this population is warranted. &
Objectives Intrathecal drug delivery systems represent an important component of interventional strategies for refractory chronic pain syndromes. Continuous intrathecal administration of opioids results in higher subarachnoid drug concentrations, improved pain scores, and less frequent side effects when compared with systemic opioid administration. Substantial costs arise at the time of surgical implantation and at revision for battery depletion or treatment of a complication. Despite current widespread use, the real-world longevity and cost of implanted intrathecal pumps (ITP) has not been fully quantified. Materials and Methods Patients with an ITP implanted at Cleveland Clinic Pain Management Center between January 1998 and December 2012 were included. ITP longevity was calculated as the time between implant and explant for depletion of the system's battery. Using the 2013 fee schedule of the Centers for Medicare & Medicaid Services, the daily cost of having a functioning ITP was calculated. The costs of office visits for pump refills and the cost of intrathecal medications were not included, nor were the possible savings due to decreased utilization of alternate medical services. Results Three hundred sixty-five patients had 559 pumps implanted. Postlaminectomy syndrome was the most common indication (40%). The median system longevity for all pumps was 5.4 years (97.5% confidence interval: [5.0, 5.8]), including pumps extracted prematurely, as well as those that reached the elective replacement interval. The median ITP longevity was 5.9 years (95% confidence interval: [5.6, 6.1]) for pumps explanted for end of battery life. The median system cost per day was $10.46. The median cost per day of pumps explanted for end of battery life was $9.26, versus $44.59 for pumps explanted prematurely due to complications. Conclusions Overall, the cohort experienced an increased incidence of pump-related complications and a device longevity that was within the range of the manufacturer's anticipated lifespan. Increasing the lifespan of the ITP and improving patient selection have the potential to significantly improve the cost-effectiveness of intrathecal therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.