IntroductIon Aortic stenosis (AS) is the most common valvular heart disease in adults, with the highest prevalence among elderly patients. Aortic valvular lesions have some similarities to atherosclerosis including chronic inflammation, the presence of lipoproteins, cholesterol, macrophages, T cells, 1 and calcification. 2 Growing evidence indicates that AS is an active, potentially modifiable inflammatory process.In contrast to multiple cytokines involved in the development of AS, adipocytokines in AS have attracted less inter est despite their role in atherosclerosis. Adiponectin, leptin, and resistin play a major role in glucose meta bolism, insulin
(1) Background: Treatment of cardiac arrhythmias and conduction disorders with the implantation of a cardiac implantable electronic device (CIED) may lead to complications. Cardiac device-related infective endocarditis (CDRIE) stands out as being one of the most challenging in terms of its diagnosis and management. Developing molecular imaging modalities may provide additional insights into CDRIE diagnosis. (2) Methods: We performed a systematic literature review to critically appraise the evidence for the diagnostic performance of the following hybrid techniques: single photon emission tomography with technetium99m-hexamethylpropyleneamine oxime–labeled autologous leukocytes (99mTc-HMPAO-SPECT/CT) and positron emission tomography with fluorodeoxyglucose (18F-FDG PET/CT). An analysis was performed in accordance with PRISMA and GRADE criteria and included articles from PubMed, Embase and Cochrane databases. (3) Results: Initially, there were 2131 records identified which had been published between 1971–2021. Finally, 18 studies were included presenting original data on the diagnostic value of 99mTc-HMPAO-SPECT/CT or 18F-FDG PET/CT in CDRIE. Analysis showed that these molecular imaging modalities provide high diagnostic accuracy and their inclusion in diagnostic criteria improves CDRIE work-up. (4) Conclusions: 99mTc-HMPAO-SPECT/CT and 18F-FDG PET/CT provide high diagnostic value in the identification of patients at risk of CDRIE and should be considered for inclusion in the CDRIE diagnostic process.
Aims
To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems.
Methods and results
Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B.
Conclusion
The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.
This paper presents results of measurements of 99mTc activity concentration in air and nuclear medical personnel blood during ventilation–perfusion SPECT lung scans. 99mTc activity measurements were conducted at the Nuclear Medicine Department, John Paul II Hospital, Krakow. Technicians and nurses who perform examinations were equipped with personal aspirators enabling air sampling to determine the radiation exposure at their workplaces. Measurements allowed to evaluate the concentration of 99mTc in 14 air samples and it ranged from 7800 ± 600 to 10,000 ± 1000 Bq m−3 for air samples collected by technicians and from 390 ± 30 to 600 ± 40 Bq m−3 for air samples collected by nurses. In addition 99mTc concentrations in blood of medical personnel were determined in 24 samples. For technicians the maximum 99mTc blood concentration levels reached 920 ± 70 Bq L−1 and 1300 ± 100 Bq L−1. In the case of nurses, the maximum estimated activity concentrations were about ten times lower, namely 71 ± 7 Bq L−1 and 39 ± 3 Bq L−1. Although the intakes appear to be relatively high, the resulting annual effective doses are about 34 µSv for technicians and only 2 µSv for nurses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.