Mitochondria utilize the majority of oxygen (O2) consumed by aerobic organisms as the final electron acceptor for oxidative phosphorylation (OXPHOS) but also to generate reactive oxygen species (mtROS) that participate in cell signaling, physiological hormesis, and disease pathogenesis. Simultaneous monitoring of mtROS production and oxygen consumption ( Jo2) from tissue mitochondrial preparations is an attractive investigative approach, but it introduces dynamic changes in media O2 concentration ([O2]) that can confound experimental results and interpretation. We utilized high-resolution fluorespirometry to evaluate Jo2 and hydrogen peroxide release ( Jh2o2) from isolated mitochondria (Mt), permeabilized fibers (Pf), and tissue homogenates (Hm) prepared from murine heart and skeletal muscle across a range of experimental [O2]s typically encountered during respirometry protocols (400–50 µM). Results demonstrate notable variations in Jh2o2 across tissues and sample preparations during nonphosphorylating (LEAK) and OXPHOS-linked respiration states at 250 µM [O2] but a linear decline in Jh2o2 of 5–15% per 50-µM decrease in chamber [O2] in all samples. Jo2 was generally stable in Mt and Hm across [O2]s above 50 µM but tended to decline below 250 µM in Pf, leading to wide variations in assayed rates of Jh2o2/O2 across chamber [O2]s and sample preparations. Development of chemical background fluorescence from the H2O2 probe (Amplex Red) was also O2 sensitive, emphasizing relevant calibration considerations. This study highlights the importance of monitoring and reporting the chamber [O2] at which Jo2 and Jh2o2 are recorded during fluorespirometry experiments and provides a basis for selecting sample preparations for studies addressing the role of mtROS in physiology and disease.
Electron beam therapy (EBT) is commonly used for treating superficial and subdermal tumors. Previous cellular radiosensitivity research using EBT may be underestimating the contribution from flask wall scattering and the corresponding dose distribution. Single cell suspensions of Chinese hamster ovary (CHO) cells were plated on flasks and irradiated with 3, 4, 7, 9, and 18 MeV energy electron beams from two different institutions, and the spatial locations of surviving colonies were recorded. Gafchromic film dosimetry and Monte Carlo simulations were carried out to determine the spatial electron scattering contribution from the flask walls. Low electron irradiation resulted in an uneven surviving colony distribution concentrated near the periphery of the flasks, while spatial colony formation was statistically uniform at energies above 7 MeV. Our data demonstrates that without proper dosimetric corrections, studies using low energy electrons can lead to misinterpretations of energy dependent cellular radiosensitivity in culture vessels, and radiotherapeutic applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.