The vibration of bearings No. 60,206 with radial clearance of 0…0.45 mm is investigated. Analysis of the frequency response (FR) of vibration acceleration reveals information frequencies of 6 Hz, 15 Hz, 26 Hz, and 46 Hz, which coincide with the calculated values. The dependence of the vibration acceleration amplitude on the radial clearance for the specified frequencies is determined. The possibility of rolling bearing wear estimation by vibroacoustic diagnostic methods using artificial neural networks is proved. Diagnostic accuracy with the 4:4-3:1 MI network ranges from 75.6% for a radial clearance of 0.15 mm to 100% for a clearance of 0 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.