BackgroundRA related foot problems can be managed by providing custom made foot orthoses (FO). A recent systematic review showed FO to be effective in reducing pain and high plantar forefoot pressures [1]. However, a moderate effect on pain reduction was found (effect size 0.45) [1]. The use of in-shoe plantar pressure measurement is a promising method for improving foot orthoses (FO). The immediate feedback from in-shoe plantar pressure measurements may be useful to evaluate and adapt FO [2]. Therefore, we developed a protocol for the use of in-shoe plantar pressure measurements to evaluate and adapt the plantar pressure distribution properties of FO in patients with RA.ObjectivesThe objectives of the present study were to evaluate (1) the outcome on plantar pressure distribution of FO that were adapted according to the protocol and (2) the feasibility of the protocol in clinical practice.MethodsForty-five RA patients with foot symptoms were included in this study. FO were custom-made by a podiatrist according to usual care. Usual care FO were constructed using prefabricated, semi-rigid FO and customized based on clinical reasoning by the podiatrist. In-shoe plantar pressure measurements were performed without FO and regions of interest (ROIs) for plantar pressure reduction were selected. Subsequent, in-shoe plantar pressure measurements with usual care FO were performed. Usual care FO were evaluated and adapted according to the developed protocol. In a within-subject design, plantar pressure-time integrals at ROIs were compared between the following conditions: (1) no-FO versus usual care FO and (2) usual care FO versus adapted FO. Semi-structured interviews were held with patients and podiatrists to evaluate the feasibility of the protocol.ResultsAdapted FO were developed in 70% of the patients. In these patients, usual care FO showed a mean 9% reduction in pressure-time integral at forefoot ROIs compared to no-FO (p=0.01). FO adaptation showed an additional mean 3% reduction in pressure-time integral (p=0.05). The protocol was considered feasible by patients. The podiatrists reported a learning effect of the protocol and considered the protocol more useful to achieve individual rather than general treatment goals.ConclusionsUsing in-shoe plantar pressure measurements for adapting foot orthoses leads to a small additional plantar pressure reduction in forefoot regions in patients with RA and foot symptoms. Further research on the clinical outcome of this approach is required.ReferencesHennessy, K., J. Woodburn, and M.P. Steultjens, Custom foot orthoses for rheumatoid arthritis: A systematic review. Arthritis Care Res (Hoboken), 2012. 64(3): p. 311-20.Bus, S.A., R. Haspels, and T.E. Busch-Westbroek, Evaluation and optimization of therapeutic footwear for neuropathic diabetic foot patients using in-shoe plantar pressure analysis. Diabetes Care, 2011. 34(7): p. 1595-600.Disclosure of InterestNone declared
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.