BRAZ DAS et al. Quality of life and depression in patients undergoing total and partial laryngectomy. CLINICS 60(2):135-142, 2005. PURPOSE: The surgical treatment of head and neck cancer, primarily laryngeal cancer, causes sequelae and can change the patient´s quality of life. The purpose of this study was to investigate the impact of laryngectomy on the quality of life regarding the functional, physical, psychological, and social aspects. METHODS: Fourteen patients underwent total laryngectomy and 16 underwent vertical partial laryngectomy. The Quality of Life Core Questionnaire (QLQ-C30) and Head and Neck (H&N35) questionnaire from the European Organization for Research and Treatment of Cancer (EORTC) were used for quality of life evaluation, while the Beck Depression Inventory questionnaire was used for the depression screen. RESULTS: In the total laryngectomy group, reported adverse effects were worsened, social and emotional function (21.3%), olfaction and taste changes (85.6%), cough (71.3%), speech difficulty (100%), and dysphagia (64.3%). Most of the patients (85.5%) judged their quality of life to be reasonable. In the partial laryngectomy group, reported adverse effects were worsened, emotional function (71.4%), speech difficulty (100%), and dysphagia (31.3%). However, most of the patients judged their quality of life to be above the general average. CONCLUSION: Despite being different surgeries, both groups experienced similar difficulties but at different levels. The quality of life was judged worse in the patients who underwent total laryngectomy.
The performance assessment and beam characteristics of the Therapax SXT 150 unit, which encompass both low and medium-energy beams, were evaluated. Dose determination was carried out by implementing the International Atomic Energy Agency (IAEA) TRS-398 protocol and measuring all the dosimetric parameters in order to have a solid, consistent and reliable data set for the unit. Mechanical movements, interlocks and applicator characteristics agreed with specifications. The timer exhibited good accuracy and linearity. The output was very stable, with good repeatability, long-term reproducibility and no dependence on tube head orientation. The measured dosimetric parameters included beam first and second half-value layers (HVLs), absorbed dose rate to water under reference conditions, central axis depth dose distributions, output factors and beam profiles. Measured first HVLs agreed with comparable published data, but the homogeneity coefficients were low in comparison with typical values found in the literature. The timer error was significant for all filters and should be taken into consideration for the absorbed dose rate determination under reference conditions as well as for the calculation of treatment times. Percentage depth-dose (PDD) measurements are strongly recommended for each filter-applicator combination. The output factor definition of the IAEA TRS-398 protocol for medium-energy X-ray qualities involves the use of data that is difficult to measure. Beam profiles had small penumbras and good symmetry and flatness except for the lowest energy beam, for which a heel effect was observed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.