This study was designed to determine whether perineural injections of local anaesthetics decreases intraoperative nociception and improves postoperative analgesia in New Zealand White rabbits undergoing experimental stifle arthrotomy. All animals were anaesthetized using isoflurane and received morphine intramuscularly. The sciatic and femoral nerves of the leg to be operated on were located using a nerve stimulator (1 Hz, 0.5 mA). Rabbits were assigned to a treatment group (LB; n = 12) or a placebo group (P; n = 12) in a randomized blinded fashion. Group LB received lidocaine 2% (1 mg/kg) combined with bupivacaine 0.5% (0.25 mg/kg) injections around the sciatic and femoral nerves (0.1 mL/kg total volume per site) and subcutaneous infiltration of the incision site with lidocaine 1% (1.25 mg/kg). Group P received the same volume of 0.9% NaCl. Rabbits in group P required higher doses of intraoperative fentanyl and propofol to reduce heart rate and suppress increase in systolic blood pressure, and maintain an adequate anaesthetic plane. Interventional analgesia (buprenorphine and carprofen) was required significantly earlier in rabbits in group P (2 and 6 h after the first nerve blockade, respectively) based on assessment of their pain-related behaviour and range of motion. Using a visual analogue scale (0 mm= no pain to 100 mm= maximal possible pain), rabbits in group LB were judged to show significantly less pain compared with rabbits in group P (14 ± 10 mm and 37 ± 25 mm, respectively) 2 h after nerve blockade. In conclusion, this technique of perineural analgesia combined with incision site infiltration reduced intraoperative fentanyl requirements and improved postoperative analgesia in rabbits.
An enantioselective assay for the determination of methadone and its main metabolite 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in equine plasma based on capillary electrophoresis with highly sulfated γ‐cyclodextrin as chiral selector and electrokinetic analyte injection is described. The assay is based on liquid/liquid extraction of the analytes at alkaline pH from 0.1 mL plasma followed by electrokinetic sample injection of the analytes from the extract across a buffer plug without chiral selector. Separation occurs cationically at normal polarity in a pH 3 phosphate buffer containing 0.16% (w/v) of highly sulfated γ‐cyclodextrin. The developed assay is precise (intra‐ and interday RSD < 4% and < 7%, respectively), is capable to determine enantiomer levels of methadone and 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in plasma down to 2.5 ng/mL, and was successfully applied to monitor enantiomer drug and metabolite levels in plasma of a pony that was anesthetized with racemic ketamine and isoflurane and received a bolus of racemic methadone and a bolus followed by constant rate infusion of racemic methadone. The data suggest that the assay is well suited for pharmacokinetic purposes.
The present study evaluated transpulmonary thermodilution (TPTD) and pulse contour cardiac output (PCCO) both measured by the PiCCO Plus™ monitor (Pulsion Medical Systems, Munich, Germany) against pulmonary artery thermodilution (PATD) in cats as a hemodynamic model for small children. A wide range of cardiac outputs (CO) was simultaneously measured. Accuracy and trending abilities were critically evaluated. Three cats were studied under isoflurane anesthesia and 160 CO measurements were performed with 3 mL ice-cold 5 % dextrose with PATD and TPTD. The results were compared with the PCCO measurement before the bolus measurement. Cardiac output was manipulated from 32 to 224 mL/kg/min by dobutamine, dopamine, phenylephrine, medetomidine and increased concentrations of isoflurane. Bland-Altman analysis, concordance and polar plot analysis were performed to assess accuracy and trending ability. TPTD was measuring constantly higher than PATD with a mean bias of 73 mL/kg/min and limits of agreement of 34-112 mL/kg/min, a concordance rate of 94 % and a mean polar angle of -5° with radial limits of agreement (RLOA) of 33°. Concordance rate of the PCCO versus PATD was 82 % with a mean polar angle of -10° and RLOA of 46° and versus TPTD 90 % with a mean polar angle of -6° and RLOA of 46°. Both tested methods constantly overestimated simultaneous PATD measurements. The small size, low flows and the relative short catheter not reaching the abdominal aorta may explain that. However TPTD tracked changes accurately opposed to a poor trending ability of the PCCO measurement.
Transversus abdominis plane (TAP) block is a regional anesthetic technique used to desensitize the abdominal wall in several species. This study aimed to describe the anatomical characteristics of the abdominal wall and to identify a feasible approach for an US-guided TAP injection that would result in adequate staining of the relevant nerves in the abdominal wall in pig cadavers. Fresh cadavers from five Landrace pigs (age, 12 weeks; body weight, 35.5 ± 1.6 kg) were used. One pig (n = 1) was anatomically dissected, and four pigs (n = 4; i.e., 8 hemiabdomens) were used for TAP injections and evaluation of dye spread. The volume of 0.3 mL/kg/injection point of methylene blue was injected bilaterally. In the caudal retrocostal approach, the injection was performed ventral to the most caudal part of the costal arch. In the lateral approach, the injection was performed between the last rib and iliac crest. A needle was inserted in plane for the caudal retrocostal and the lateral approach caudocranially and craniocaudally, respectively. Successful staining was defined as presence of dye on the nerve for a length of >1 cm in its entire circumference. The TAP was found between different muscle layers in the described anatomical regions. In the caudal retrocostal approach the TAP was found between the external abdominal oblique and transversus abdominis muscle bellies. In the lateral approach the TAP was found between the internal abdominal oblique and transversus abdominis muscles. The approach combining lateral and caudal retrocostal injections at the studied volume stained a median of 5 (3–6) target nerves from the fourth-last thoracic nerve to L2 (six nerves). Combined caudal retrocostal and lateral TAP injections of 0.3 mL/kg/injection point, resulted in staining of target nerve branches which supply the periumbilical and caudal abdominal wall in pig cadavers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.