Stent misplacement during endovascular treatment of middle cerebral artery (MCA) aneurysms can cause challenges and be problematic, if clipping becomes necessary. This article reports on a 56-year-old woman with an unruptured, multi-lobulated MCA aneurysm, whom primarily refused surgery; therefore, she was scheduled for stent-assisted coiling. After successful deployment of the stent, it unfortunately then became snagged by the microcatheter and was pulled backwards. The subsequent surgical procedure (i.e. clipping of the MCA aneurysm) was challenging, due to the position of the dislodged stent. Such as misplacement of the stent is rarely documented: It resulted in the difficult handling of a MCA aneurysm. Aneurysms of the MCA should primarily be considered for surgical clipping. In conclusion, an increased risk for eventual surgery should be considered, in cases where endovascular treatments with stents are performed.
BACKGROUND AND PURPOSE:The computerized occlusion rating to estimate angiographic occlusion of embolized aneurysms is superior to the subjective occlusion rating. In this study, we compared the 2 methods in the analysis of aneurysms clipped after subarachnoid hemorrhage.
Background
Endovascular therapy has revolutionized the treatment of cerebral aneurysms in recent years and decades. So-called intrasaccular devices (i.e., Woven EndoBridge (WEB), MicroVention, Aliso Viejo, CA, or Contour, Cerus Neurovascular, Fremont, CA) are a promising endovascular technology, especially for wide-based aneurysms. However, long-term outcome data are currently particularly scarce for Contour and strategies for failed Contour cases are lacking. Here, we report the feasibility of microsurgical clipping after failed Contour device embolization.
Methods
Feasibility of microsurgical clipping after failed aneurysm embolization with a Contour intrasaccular device was assessed in a patient.
Results
We present a case of a 36-year-old male patient diagnosed with Hunt and Hess grade 1 subarachnoid hemorrhage from an anterior communicating artery aneurysm. The ruptured aneurysm was initially treated with the Contour device. After 3 months, angiographic imaging showed a clear aneurysm residual deemed not endovascularly accessible. The patient was then successfully clipped using microsurgical techniques. The patient was discharged with no neurological abnormalities.
Conclusion
After thorough bibliographical research, this presents the first published case report of microsurgical clipping after failed embolization with Contour. The main insights gained after clipping were that the Contour does not significantly disturb or hinder clipping. In contrast to coils in aneurysms to be clipped, the Contour can be easily compressed by the clip blades and does not have to be removed. In addition, the Contour had not migrated into the subarachnoid space and there was no abnormal scarring. Clipping appears to be a reasonable treatment strategy for failure of embolization with Contour if endovascular means are not suitable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.