The x-ray spectrum between 18 and 88 keV generated by a petawatt laser driven x-ray backlighter target was measured using a 12-channel differential filter pair spectrometer. The spectrometer consists of a series of filter pairs on a Ta mask coupled with an x-ray sensitive image plate. A calibration of Fuji™ MS and SR image plates was conducted using a tungsten anode x-ray source and the resulting calibration applied to the design of the Ross pair spectrometer. Additionally, the fade rate and resolution of the image plate system were measured for quantitative radiographic applications. The conversion efficiency of laser energy into silver Kα x rays from a petawatt laser target was measured using the differential filter pair spectrometer and compared to measurements using a single photon counting charge coupled device.
The Static X-ray Imager (SXI) at the National Ignition Facility (NIF) is a pinhole camera using a CCD detector to obtain images of hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters combined with the CCD response allows recording images in the x-ray range of 3 to 5 keV with 60 µm spatial resolution. The routines used to obtain the apparent size of the backlit LEH, and the location and intensity of beam spots are discussed and compared to predictions. A new soft xray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition hohlraum) is discussed.
An x-ray streak camera platform has been characterized and implemented for use at the National Ignition Facility. The camera has been modified to meet the experiment requirements of the National Ignition Campaign and to perform reliably in conditions that produce high electromagnetic interference. A train of temporal ultra-violet timing markers has been added to the diagnostic in order to calibrate the temporal axis of the instrument and the detector efficiency of the streak camera was improved by using a CsI photocathode. The performance of the streak camera has been characterized and is summarized in this paper. The detector efficiency and cathode measurements are also presented.
Line emission and broadband x-ray sources with x-ray energies above 10 keV have been investigated using a range of calibrated x-ray detectors for use as x-ray backlighters in high energy density (HED) experiments. The conversion efficiency of short-and long-pulse driven Mo and Ag line-emission backlighters at 17 and 22 keV was measured to investigate the crossover region between short-and long-pulse conversion efficiency. It was found that significant 17 and 22 keV line emissions were observed using a 3 x, 1 ns long-pulse drive for Mo and Ag targets and a comparison between the measured Mo x-ray spectrum and calculations using an atomic physics code suggests that the line emission is due to thermal emission from N-like Mo atoms. Electron temperatures derived from fits to the continuum region of the x-ray spectra agree well with the T hot scaling as 100 Â ðIk 2 Þ 1=3. The continuum emissions from empty and 1 atm Kr-filled imploded CH shell targets were also measured for the use as broadband backlighters. V
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.