1H imaging is concerned with contrast generation among anatomically distinct soft tissues. X‐nuclei imaging, on the other hand, aims to reveal the underlying changes in the physiological processes on a cellular level. Advanced clinical MR hardware systems improved 1H image quality and simultaneously enabled X‐nuclei imaging. Adaptation of 1H methods and optimization of both sequence design and postprocessing protocols launched X‐nuclei imaging past feasibility studies and into clinical studies. This review outlines the current state of X‐nuclei MRI, with the focus on 23Na, 35Cl, 39K, and 17O. Currently, various aspects of technical challenges limit the possibilities of clinical X‐nuclei MRI applications. To address these challenges, quintessential physical and technical concepts behind different applications are presented, and the advantages and drawbacks are delineated. The working process for methods such as quantification and multiquantum imaging is shown step‐by‐step. Clinical examples are provided to underline the potential value of X‐nuclei imaging in multifaceted areas of application. In conclusion, the scope of the latest technical advance is outlined, and suggestions to overcome the most fundamental hurdles on the way into clinical routine by leveraging the full potential of X‐nuclei imaging are presented. Level of Evidence: 1 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020;51:355–376.
Magnetic resonance (MR)-only radiotherapy treatment planning requires pseudo-CT (pCT) images to enable MR-based dose calculations. To verify the accuracy of MR-based dose calculations, institutions interested in introducing MR-only planning will have to compare pCT-based and computer tomography (CT)-based dose calculations. However, interpreting such comparison studies may be challenging, since potential differences arise from a range of confounding factors which are not necessarily specific to MR-only planning. Therefore, the aim of this study is to identify and quantify the contribution of factors confounding dosimetric accuracy estimation in comparison studies between CT and pCT. The following factors were distinguished: set-up and positioning differences between imaging sessions, MR-related geometric inaccuracy, pCT generation, use of specific calibration curves to convert pCT into electron density information, and registration errors.The study comprised fourteen prostate cancer patients who underwent CT/ MRI-based treatment planning. To enable pCT generation, a commercial solution (MRCAT, Philips Healthcare, Vantaa, Finland) was adopted. IMRT plans were calculated on CT (gold standard) and pCTs. Dose difference maps in a high dose region (CTV) and in the body volume were evaluated, and the contribution to dose errors of possible confounding factors was individually quantified.We found that the largest confounding factor leading to dose difference was the use of different calibration curves to convert pCT and CT into electron density (0.7%). The second largest factor was the pCT generation Inter-scan differences due to patient repositioning, MR-related geometric inaccuracy, and registration errors did not significantly contribute to dose differences (0.01%). The proposed approach successfully identified and quantified the factors confounding accurate MRI-based dose calculation in the prostate. This study will be valuable for institutions interested in introducing MR-only dose planning in their clinical practice.
Purpose To capture the multiquantum coherence (MQC) 23 Na signal. Different phase‐cycling options and sequences are compared in a unified theoretical layout, and a novel sequence is developed. Methods An open source simulation overview is provided with graphical explanations to facilitate MQC understanding and access to techniques. Biases such as B 0 inhomogeneity and stimulated echo signal were simulated for 4 different phase‐cycling options previously described. Considerations for efficiency and accuracy lead to the implementation of a 2D Cartesian single and triple quantum imaging of sodium (CRISTINA) sequence employing two 6‐step cycles in combination with a multi‐echo readout. CRISTINA was compared to simultaneous single‐quantum and triple‐quantum‐filtered MRI of sodium (SISTINA) under strong static magnetic gradient. CRISTINA capabilities were assessed on 8 × 60 mL, 0% to 5% agarose phantom with 50 to 154 mM 23 Na concentration at 7 T. CRISTINA was demonstrated subsequently in vivo in the brain. Results Simulation of B 0 inhomogeneity showed severe signal dropout, which can lead to erroneous MQC measurement. Stimulated echo signal was highest at the time of triple‐quantum coherences signal maximum. However, stimulated echo signal is separated by Fourier Transform as an offset and did not interfere with MQC signals. The multi‐echo readout enabled capturing both single‐quantum coherences and triple‐quantum coherences signal evolution at once. Signal combination of 2 phase‐cycles with a corresponding B 0 map was found to recover the signal optimally. Experimental results confirm and complement the simulations. Conclusion Considerations for efficient MQC measurements, most importantly avoiding B 0 signal loss, led to the design of CRISTINA. CRISTINA captures triple‐quantum coherences and single‐quantum coherences signal evolution to provide complete sodium signal characterization including fast, slow, MQC amplitudes, and sodium concentration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.