We present commissioning and validation of Fred, a graphical processing unit (GPU)–accelerated Monte Carlo code, for two proton beam therapy facilities of different beam line design: CCB (Krakow, IBA) and EMORY (Atlanta, Varian). We followed clinical acceptance tests required to approve the certified treatment planning system for clinical use. We implemented an automated and efficient procedure to build a parameter library characterizing the clinical proton pencil beam. Beam energy, energy spread, lateral propagation model, and a dosimetric calibration factor were parametrized based on measurements performed during the facility start-up. The Fred beam model was validated against commissioning and supplementary measurements performed with and without range shifter. We obtained 1) submillimeter agreement of Bragg peak shapes in water and lateral beam profiles in air and slab phantoms, 2) <2% dose agreement for spread out Bragg peaks of different ranges, 3) average gamma index (2%/2 mm) passing rate of >95% for >1000 patient verification measurements using a two-dimensional array of ionization chambers, and 4) gamma index passing rate of >99% for three-dimensional dose distributions computed with Fred and measured with an array of ionization chambers behind an anthropomorphic phantom. The results of example treatment planning study on >100 patients demonstrated that Fred simulations in computed tomography enable an accurate prediction of dose distribution in patient and application of Fred as second patient quality assurance tool. Computation of a patient treatment in a CT using 104 protons per pencil beam took on average 2′30 min with a tracking rate of 2.9×105p+/s. Fred was successfully commissioned and validated against the clinical beam model, showing that it could potentially be used in clinical routine. Thanks to high computational performance due to GPU acceleration and an automated beam model implementation method, the application of Fred is now possible for research or quality assurance purposes in most of the proton facilities.
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.