We report the electrochemical detection of the redox active cardiac biomarker myoglobin (Mb) using aptamer-functionalized black phosphorus nanostructured electrodes by measuring direct electron transfer. The as-synthesized few-layer black phosphorus nanosheets have been functionalized with poly-l-lysine (PLL) to facilitate binding with generated anti-Mb DNA aptamers on nanostructured electrodes. This aptasensor platform has a record-low detection limit (∼0.524 pg mL(-1)) and sensitivity (36 μA pg(-1) mL cm(-2)) toward Mb with a dynamic response range from 1 pg mL(-1) to 16 μg mL(-1) for Mb in serum samples. This strategy opens up avenues to bedside technologies for multiplexed diagnosis of cardiovascular diseases in complex human samples.
Ga(+) Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga(+) FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe(+) Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC-Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga(+) FIB milling WC-Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60nA at 30kV. Xe(+) PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography.
Significant elemental segregation is shown to exist within individual hollow silver-gold (Ag-Au) bimetallic nanoparticles obtained from the galvanic reaction between Ag particles and AuCl4(-). Three-dimensional compositional mapping using energy dispersive X-ray (EDX) tomography within the scanning transmission electron microscope (STEM) reveals that nanoparticle surface segregation inverts from Au-rich to Ag-rich as Au content increases. Maximum Au surface coverage was observed for nanoparticles with approximately 25 atom % Au, which correlates to the optimal catalytic performance in a three-component coupling reaction among cyclohexane carboxyaldehyde, piperidine, and phenylacetylene.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.