We present recent measurements of absolute electron-impact ionization cross sections for Be-like C iii, N iv, and O v forming Li-like C iv, N v, and O vi. The measurements were taken using the crossed-beams apparatus at Oak Ridge National Laboratory. A gas cell beam attenuation method was used to independently measure the metastable fractions present in the ion beams. The measured ionization cross sections were compared with calculations using the R-matrix with pseudostates and distorted-wave theoretical methods. Best agreement is found with the R-matrix with pseudostates cross sections results that account for the metastable fractions inferred from the gas attenuation measurements. We present a set of recommended rate coefficients for electron-impact single ionization from the ground state and metastable term of each ion.
The absolute total recombination reaction rate coefficients for Be-like C, N, and O have been measured using the CRYRING storage ring and compared with the results from distorted-wave theory. For the theory results, it is found that shifts to NIST energy values for the core excited energies of the recombining system are not sufficient to accurately match all of the resonance positions and heights at lower energies. These theory results represent the quality of most archived theory DR data. The accurate calculation of these low energy resonances still presents a significant challenge to theory. In addition, trielectronic recombination resonances, associated with the formation of triply excited states during recombination, have been observed in the total recombination reaction rate coefficient spectra of N 3+ and O 4+. Finally, we construct a dielectronic recombination Maxwellian rate coefficient from the experimental results for low n resonances, and from the theoretical results for high n resonances. In the case of O 4+ , the trielectronic recombination resonances have a strong influence on the low temperature Maxwellian rate coefficient. Our best hybrid Maxwellian rate coefficient is compared with archived distorted-wave theory data, and is found to be in reasonable agreement, even at the low temperatures.
Unmanned aircraft systems (UAS) allow us to collect aerial data at high spatial and temporal resolution. Raw images are taken along a predetermined flight path and processed into a single raster file covering the entire study area. Radiometric calibration using empirical or manufacturer methods is required to convert raw digital numbers into reflectance and to ensure data accuracy. The performance of five radiometric calibration methods commonly used was investigated in this study. Multispectral imagery was collected using a Parrot Sequoia camera. No method maximized data accuracy in all bands. Data accuracy was higher when the empirical calibration was applied to the processed raster rather than the raw images. Data accuracy achieved with the manufacturer-recommended method was comparable to the one achieved with the best empirical method. Radiometric error in each band varied linearly with pixel radiometric values. Smallest radiometric errors were obtained in the red-edge and near-infrared (NIR) bands. Accuracy of the composite indices was higher for the pixels representing a dense vegetative cover in comparison to a lighter cover or bare soil. Results provided a better understanding of the advantages and limitations of existing radiometric calibration methods as well as the impact of the radiometric error on data quality. The authors recommend that researchers evaluate the performance of their radiometric calibration before analyzing UAS imagery and interpreting the results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.