BackgroundParenteral drug administration plays an important role in hospitals. It is well known that a certain amount of a drug remains at the end of the infusion and is not administered to the patient because of the dead volume: this dead volume could be the origin of an underdosing.PurposeThe aim of this study is to determine the dead volume of the injectable delivery system including the serum bag, perfusion tubulure, syringe and short catheter used for the reconstitution and administration of injectable drugs, and its impact on variation of the prepared doses.Material and methodsWe weighed, using an analytical balance, all the medical devices (serum bag, perfusion tubulure, syringe and short catheter) used in the administration of an injectable drug before and after the passage of an antibiotic solution. We can thus determine the dead volume remaining in each material. Statistical analysis were performed with SPSS 13. 0.ResultsThe table shows that the dead volume differed between medical devices (p<0.001). It was significant for the serum bag and perfusion tubulure, and low for syringes and short catheters. The overall dead volume is estimated at 4.5±1.7 mL.Abstract 3PC-031 Table 1 Medical device Dead volume mean± SD (mL) (n =30 ) Serum bag 2.61±1.71 Syringe 2.5 mL 0.06±0.003 Syringe 5 mL 0.07±0.003 Syringe 10 mL 0. 07±0. 003 Syringe 50 mL 0.09±0.003 Perfusion tubulure 1.74±0.02 Short catheter G22 0.01±0.001 Short catheter G24 0.01±0.003 ConclusionA considerable amount of the infusion volume, and therefore of the antibiotic, depending on the concentration, is lost at the end of the infusion due to the dead volume depending on the medical devices used as demonstrated in this study and in other studies.1 Loss of a potential amount of a drug can constitute a problem regarding safety and efficacy of therapy, especially for drugs with narrow therapeutic margins. This is especially important for the serum bag and perfusion tubulure, where the dead volume is about 2.61 mL and 1.74 mL respectively.References and/or Acknowledgements1. Cheikh A, Rhali Y, Mefetah H, Sbai I, Mojemmi B, Draoui M, Bouatia M. The influence of the dead volume of the closed system (spike–connector–syringe) on the reconstitution of injectable drugs. Eur J Hosp Pharm24(1):A214–A216.No conflict of interest
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.