Testing the fatigue crack growth of materials at low frequencies and realistic stress intensity factors has historically demanded a large investment in time.Running a test at a frequency less than 1 Hz can take weeks, and if meaningful statistics are needed, 2-3 months might be necessary to provide one set of data on the fatigue crack growth rate (FCGR). A means of reducing that time frame by testing as many as 10 specimens simultaneously is presented. With this innovative design, compact tension specimens are run in series and according to ASTM Standard E647. Furthermore, there is no need to interrupt the fatigue testing of the linked specimens should one or more finish before the others. Specimens tested in this fashion generate consistent data of FCGR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.