Scrapie is a fatal neurodegenerative disease of sheep and goats belonging to the group of Transmissible Spongiform Encephalopathy or prion diseases. The EU has adopted mandatory measures for scrapie surveillance to safeguard public and animal health because it is highly contagious and might decimate all genetic susceptible animals in affected flocks. Definite diagnosis of scrapie relies on the detection of the pathological prion protein in brain tissues and there are still no blood biomarkers available for making diagnosis in living animals that can be used for the screening of sheep in scrapie-affected flocks. Neurofilament light (NfL) protein, a valid biomarker for neuronal and axonal damages, can now be easily measured in blood by the ultra-sensitive single molecule array (Simoa) technology. Recent work reported that serum NfL is increased in neurodegenerative diseases, including human prion diseases, but no data are available for scrapie or other animal prion diseases. Here, we found that the median serum NfL concentration in scrapie animals (56.2, IQR 42.2–84.8, n = 9) was more than 15 times higher (p = 0.00084) than that found in control samples (3.4, IQR 3.0–26.3, n = 11). Moreover, serum NfL concentration in scrapie sheep with clinical signs (n = 2; 75.3, 15.7 pg/ml) did not significantly (p = 0.541; t-test) differ from scrapie animals without clinical signs (n = 7; 61.0, 10.7 pg/ml). The receiver operating characteristic (ROC) curve analysis estimated the cut-off value of 31 pg/ml serum NfL for distinguishing scrapie-infected sheep from controls. The application of this cut-off value gives an accuracy of the test of 95% (percent error of 5.23%). These data indicate that the Simoa test for serum NfL might be a useful screening method for detecting preclinical scrapie in living sheep. Finally, the preliminary data reported here need confirmation in large and more structured studies.
BackgroundRoutine rapid testing for Bovine Spongiform Encephalopathy (BSE) has highlighted some problems with BSE rapid test performance, the most significant being the number of initially reactive samples and the false positive results on autolyzed tissue. This point is important for BSE active surveillance in risk populations, because tissue autolysis is often unavoidable in routine cases. A robust test suitable for use on field material is therefore needed. To date, very limited information regarding the effect of autolysis on the robustness of rapid tests has been documented; therefore, the National Reference Centre for Animal Encephalopathies (CEA) rapid test laboratory selected 450 autolyzed and negative brain stem samples from fallen stock bovines older than 24 months to assess the specificity of four tests approved for BSE active surveillance: Biorad TeSeE, Enfer TSE version 2.0, Prionics® Check LIA, and IDEXX Herd Check BSE Antigen Kit EIA. The samples were graded according to the degree of autolysis and then dissected into five portions, four of which randomly assigned to processing by rapid tests and one to be available for confirmatory Western blot analysis.FindingsThe specificity of the four systems was 100% for all three grades of autolysis, while the percentage of initially reactive results was 0.00 (95%CI 0.00-0.82), 0.22 (95%CI 0.006-1.23), 0.44 (95%CI 0.05-1.60), and 0.89 (95%CI 0.24-2.26) for the Biorad TeSeE, the Prionics® Check LIA, the IDEXX Herd Check BSE and the Enfer TSE tests, respectively. No association with the degree of autolysis could be drawn.ConclusionsThe present study demonstrates that the four rapid tests can be considered well-running diagnostic tools regardless of tissue quality; nevertheless, the number of initial reactive samples reported for some systems must not be underestimated in routine testing.Furthermore the compliance with the reported performance can be guaranteed only when an ongoing high careful batch quality control system is in place.
These authors contributed equally to this work.
Instrument Voltage Transformers (IVTs) introduce errors in power quality measure due to resonance's effects at high frequency. The accuracy of IVTs, definite by standards, is only about nominal frequency and does not consider high frequency response. The paper reports the IVTs experimental analysis on resonance's disturbances transferred to secondary side of Instrument Voltage Transformer. In particular the main results obtained from a laboratory survey on three currently marketed IVTs with same features but different manufacture are presented. IVTs are tested with very fast front voltage impulse whose waveform is similar to the characteristic one of SF 6 switches operations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.