Campbell, B. C.V. et al. (2019) Penumbral imaging and functional outcome in patients with anterior circulation ischaemic stroke treated with endovascular thrombectomy versus medical therapy: a meta-analysis of individual patient-level data.ABSTRACT Background: CT-perfusion (CTP) and MRI may assist patient selection for endovascular thrombectomy. We aimed to establish whether imaging assessments of ischaemic core and penumbra volumes were associated with functional outcomes and treatment effect.
Campbell, B. C. V. et al. (2018) Effect of general anaesthesia on functional outcome in patients with anterior circulation ischaemic stroke having endovascular thrombectomy versus standard care: a meta-analysis of individual patient data. Lancet Neurology, 17(1), pp. 47-53. (doi:10.1016/S1474-4422(17)30407-6) This is the author's final accepted version.There may be differences between this version and the published version. You are advised to consult the publisher's version if you wish to cite from it.http://eprints.gla.ac.uk/149670/ variables. An alternative approach using propensity-score stratification was also used. To account for between-trial variance we used mixed-effects modeling with a random effect for trial incorporated in all models. Bias was assessed using the Cochrane tool.Findings: Of 1764 patients in 7 trials, 871 were allocated to endovascular thrombectomy. After exclusion of 74 patients (72 who did not undergo the procedure and 2 with missing data on anaesthetic strategy), 236/797 (30%) of endovascular patients were treated under GA. At baseline, GA patients were younger and had shorter time to randomisation but similar pre-treatment clinical severity compared to non-GA. Endovascular thrombectomy improved functional outcome at 3 months versus standard care in both GA (adjusted common odds ratio (cOR) 1·52, 95%CI 1·09-2·11, p=0·014) and non-GA (adjusted cOR 2·33, 95%CI 1·75-3·10, p<0·001) patients. However, outcomes were significantly better for those treated under non-GA versus GA (covariate-adjusted cOR 1·53, 95%CI 1·14-2·04, p=0·004; propensitystratified cOR 1·44 95%CI 1·08-1·92, p=0·012). The risk of bias and variability among studies was assessed to be low.Interpretation: Worse outcomes after endovascular thrombectomy were associated with GA, after adjustment for baseline prognostic variables. These data support avoidance of GA whenever possible. The procedure did, however, remain effective versus standard care in patients treated under GA, indicating that treatment should not be withheld in those who require anaesthesia for medical reasons. Funding:The HERMES collaboration was funded by an unrestricted grant from Medtronic to the University of Calgary. Research in contextEvidence before this study between abolition of the thrombectomy treatment effect in MR CLEAN and no effect in THRACE. Three single-centre randomised trials of general anaesthesia versus conscious sedation found either no difference in functional outcome between groups or a slight benefit of general anaesthesia. Added value of this studyThese data from contemporary, high quality randomised trials form the largest study to date of the association between general anesthesia and the benefit of endovascular thrombectomy versus standard care. We used two different approaches to adjust for baseline imbalances (multivariable logistic regression and propensity-score stratification). We found that GA for endovascular thrombectomy, as practiced in contemporary clinical care across a wide range of expert centres during the rand...
Background: Source plasma (SP) is the primary starting material for 87% of plasma-derived medicinal products globally. Plasmavigilance is a program designed to collect, analyze, and monitor donor adverse events (AEs) across the SP collection industry. Donor retention depends on donors having a safe and satisfactory experience. This study analyzes AE rates and SP donor characteristics that may be predictors of an AE. Study Design and Methods: Donation data for 1.1 million donors making 12,183,182 SP donations over a 4-month period were analyzed. This represented approximately 72% of the donations collected by the U.S. plasma industry. The Standard for Recording Donor Adverse Events was used for AE definitions and classifications.Results: The overall AE rate was 15.85/10 4 donations. The two AEs with the highest rates were Hypotensive and Phlebotomy events (8.32 and 5.91/10 4 donations, respectively). Females had higher overall AE rates than males (25.76 vs. 9.85/10 4 donations), and first-time donors had higher overall AE rates than repeat donors (136.66 vs. 12.37/10 4 donations). Weight, body mass index, age, and pre-donation estimated blood volume also were predictors of AE.Discussion: SP donors have low AE rates with 90% being events classified as Hypotensive or Phlebotomy. Special attention and mitigation strategies should be directed to donors who are young, lightweight (between 100 and 124 pounds), female, or first-time donors to further reduce the incidence of AE, continue to ensure the donor has a safe experience, and facilitate donor retention.
Background The prehospital identification of stroke patients with large-vessel occlusion (LVO), that should be immediately transported to a thrombectomy capable centre is an unsolved problem. Our aim was to determine whether implementation of a state-wide standard operating procedure (SOP) using the Los Angeles Motor Scale (LAMS) is feasible and enables correct triage of stroke patients to hospitals offering (comprehensive stroke centres, CSCs) or not offering (primary stroke centres, PSCs) thrombectomy. Methods Prospective study involving all patients with suspected acute stroke treated in a 4-month period in a state-wide network of all stroke-treating hospitals (eight PSCs and two CSCs). Primary endpoint was accuracy of the triage SOP in correctly transferring patients to CSCs or PSCs. Additional endpoints included the number of secondary transfers, the accuracy of the LAMS for detection of LVO, apart from stroke management metrics. Results In 1123 patients, use of a triage SOP based on the LAMS allowed triage decisions according to LVO status with a sensitivity of 69.2% (95% confidence interval (95%-CI): 59.0–79.5%) and a specificity of 84.9% (95%-CI: 82.6–87.3%). This was more favourable than the conventional approach of transferring every patient to the nearest stroke-treating hospital, as determined by geocoding for each patient (sensitivity, 17.9% (95%-CI: 9.4–26.5%); specificity, 100% (95%-CI: 100–100%)). Secondary transfers were required for 14 of the 78 (17.9%) LVO patients. Regarding the score itself, LAMS detected LVO with a sensitivity of 67.5% (95%-CI: 57.1–78.0%) and a specificity of 83.5% (95%-CI: 81.0–86.0%). Conclusions State-wide implementation of a triage SOP requesting use of the LAMS tool is feasible and improves triage decision-making in acute stroke regarding the most appropriate target hospital.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.