Phase contrast x-ray imaging is a powerful technique for the detection of low-contrast details in weakly absorbing objects. This method is of possible relevance in the field of diagnostic radiology. In fact, imaging low-contrast details within soft tissue does not give satisfactory results in conventional x-ray absorption radiology, mammography being a typical example. Nevertheless, up to now all applications of the phase contrast technique, carried out on thin samples, have required radiation doses substantially higher than those delivered in conventional radiological examinations. To demonstrate the applicability of the method to mammography we produced phase contrast images of objects a few centimetres thick while delivering radiation doses lower than or comparable to doses needed in standard mammographic examinations (typically approximately 1 mGy mean glandular dose (MGD)). We show images of a custom mammographic phantom and of two specimens of human breast tissue obtained at the SYRMEP bending magnet beamline at Elettra, the Trieste synchrotron radiation facility. The introduction of an intensifier screen enabled us to obtain phase contrast images of these thick samples with radiation doses comparable to those used in mammography. Low absorbing details such as 50 microm thick nylon wires or thin calcium deposits (approximately 50 microm) within breast tissue, invisible with conventional techniques, are detected by means of the proposed method. We also find that the use of a bending magnet radiation source relaxes the previously reported requirements on source size for phase contrast imaging. Finally, the consistency of the results has been checked by theoretical simulations carried out for the purposes of this experiment.
The efficacy and safety of nonionic dimeric contrast media in subjects with impaired renal function is largely unknown. The present study was aimed at determining the risk of tubular nephrotoxicity in patients with mild to moderate renal insufficiency who underwent intravenous urography (IVU) with the nonionic dimeric contrast agent iodixanol (Visipaque, Nycomed Imaging, Oslo, Norway). In a double-blind protocol 64 patients (55 males; mean age 68.3 years) with serum creatinine between 135 and 265 micromol/l who were to undergo IVU were randomized to receive iodixanol (a nonionic dimer) or iopromide (a nonionic monomer), 600 mg I/kg b. w. Renal function was evaluated before and 1 h, 6 h, 24 h, 48 h and 7 days after IVU with analysis of serum creatinine, urinary enzymes alanylaminopeptidase and N-acetyl-beta-glucosaminidase, and urinary microproteins alpha-1-microglobulin and albumin. Renal function remained stable in both contrast medium groups during the follow-up period. No statistically significant differences were observed between the monomer and the dimer in terms of urinary enzyme and microprotein excretion or serum creatinine. Transient radiocontrast-induced nephropathy developed in 1 patient who had received iodixanol. The administration of the nonionic dimeric contrast medium iodixanol, or of the nonionic monomer iopromide, entailed a low nephrotoxic potential in patients with mild to moderate renal insufficiency undergoing excretory urography.
Non-ionic dimers induce less diuresis than non-ionic monomers, resulting in increased opacification of the urinary tract in intravenous (i.v.) urography. This double blind, comparative, randomized, parallel trial compared the efficacy of iodixanol (non-ionic dimer) and iopromide (non-ionic monomer) in 100 patients with mild to moderate renal insufficiency (serum creatinine of 135 to 265 mumol l-1) who underwent i.v. urography. A total dose of 600 mgI kg-1 bw of iodixanol (320 mgI ml-1) or iopromide (300 mgI ml-1) was injected. Radiographs were blindly evaluated by three radiologists who analysed different parameters (renal border visualization, nephrogram density, calyceal filling and density, papillary blush detection, delineation of collecting ducts, renal pelvis opacification, visualization of ureters, bladder density, bladder distention). Densitometric evaluation on the renal pelvis and bladder was also performed. Iodixanol showed better filling and density of the calyces (p = 0.004), more frequent detection of papillary blush (p = 0.003) and better opacification of the renal pelvis (p = 0.006). No significant differences between the two contrast media were found in regard to other parameters. In conclusion, the results confirmed theoretical expectations. The non-ionic dimer iodixanol is to be preferred to a non-ionic monomer such as iopromide in i.v. urography on patients with impaired renal function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.