Polyoxometalates or POMs, a class of inorganic transition metal-oxide based clusters, have gained significant interest owing to their catalytic, magnetic, and material science applications. All such applications require high surface area POM based materials. However, chemically synthesized POMs are still at most in the range of a few nanometers, with their size and morphology being difficult to control. Hence, there is an immediate need to develop design principles that allow easy control of POM morphology and size on mesoscopic (50-500 nm) length scales. Here, we report a design strategy to meet this need. Our method reported here avoids a complex chemical labyrinth by using a prefabricated cationic 1,2-dioleol-3-trimethylammonium-propane (DOTAP) vesicle as a scaffold/structure directing agent and gluing simple anionic heptamolybdates by electrostatic interaction and hydrogen bonds to form large POM spheres. By this method, complexity in the resulting structure can be deliberately induced either via the scaffold or via the oxometalate. The high degree of control in the matter of the size and morphology of the resulting POM superstructures renders this method attractive from a synthetic standpoint.
Alcohol abuse is a widespread problem, especially in Western countries. Therefore, it is important to have markers of alcohol consumption with validated cut-off points. For many years research has focused on analysis of hair for alcohol markers, but data on the performance and reliability of cut-off values are still lacking. Evaluating 1,057 cases from 2005 to 2011, included a large sample group for the estimation of an applicable cut-off value when compared to earlier studies on fatty acid ethyl esters (FAEEs) in hair. The FAEEs concentrations in hair, police investigation reports, medical history, and the macroscopic and microscopic alcohol-typical results from autopsy, such as liver, pancreas, and cardiac findings, were taken into account in this study. In 80.2 % of all 1,057 cases pathologic findings that may be related to alcohol abuse were reported. The cases were divided into social drinkers (n = 168), alcohol abusers (n = 502), and cases without information on alcohol use. The median FAEEs concentration in the group of social drinkers was 0.302 ng/mg (range 0.008-14.3 ng/mg). In the group of alcohol abusers a median of 1.346 ng/mg (range 0.010-83.7 ng/mg) was found. Before June 2009 the hair FAEEs test was routinely applied to a proximal hair segment of 0-6 cm, changing to a routinely investigated hair length of 3 cm after 2009, as proposed by the Society of Hair Testing (SoHT). The method showed significant differences between the groups of social drinkers and alcoholics, leading to an improvement in the postmortem detection of alcohol abuse. Nevertheless, the performance of the method was rather poor, with an area under the curve calculated from receiver operating characteristic (ROC curve AUC) of 0.745. The optimum cut-off value for differentiation between social and chronic excessive drinking calculated for hair FAEEs was 1.08 ng/mg, with a sensitivity of 56 % and a specificity of 80 %. In relation to the "Consensus on Alcohol Markers 2012" by the SoHT, an increase in the cut-off value for FAEEs in the proximal hair segment 0-3 cm from 0.5 to 1 ng/mg may be advisable to avoid excessive numbers of false positive results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.